Nieco MPB94 Скачать руководство пользователя страница 1

Nieco MPB94 Gas 

Preventative Maintenance 

Guide 

May 16, 2017 

Final 

Содержание MPB94

Страница 1: ...Nieco MPB94 Gas Preventative Maintenance Guide May 16 2017 Final...

Страница 2: ...d replace if needed 6 Inspect flame arrestors for breaks and warping from heat 7 Inspect lower and upper burners for cracks and plugged burner ports 8 If equipped Inspect the Incendalyst for damage an...

Страница 3: ...r gas leaks with bubbles 5 Inspect restraining cable and fastenings 6 Inspect broiler frame cross rods supports 7 Remove and Inspect lower burners 8 Inspect flame arrestors 9 Inspect Incendalyst Catal...

Страница 4: ...Assembly...

Страница 5: ...Assembly...

Страница 6: ...White PTFE Bearings FEED END DISCHARGE END P N 6047 P N 6046 P N 6049 P N 6049 1 Inspect all 4 PTFE Bearings and replace if worn Example...

Страница 7: ...or excessive warping Replace with the new style flame arrestor New Style This Flame Arrestor is a frame assembly and two replaceable arrestor screens With this design you replace only the defective s...

Страница 8: ...using high temperature grease 2 Remove cover and lubricate Feeder Chains Main and Flex sides We suggest using high temperature grease 3 Remove feeder drive and replace white shoulder bushing 4 Instal...

Страница 9: ...n Parts Hot Surface Igniter Flame Sensor 1 Replace the Hot Surface Igniter 2 Replace the Flame Sensor Hot Surface Igniter Flame Sensor Note Broilers built in 2006 require snap in flame sensor and sepa...

Страница 10: ...present remove all the mounting clips for the upper heating elements on both the main and flex side of the broiler and discard 2 Inspect all elements for cracks bowing and excessive corrosion Element...

Страница 11: ...Replace Pilot Burners Upper Pilot Burner P N 2180 Lower Pilot Burner P N 2179...

Страница 12: ...ilot 3225 2182 2 2 Orifice Zip Tube 75 2185 1 3 Orifice Main Burner 42 16590 4 4 Orifice Main Burner 46 2051 1 5 Orifice Main Burner 45 14045 1 Orifices LP Gas Description Part Qty 1 Orifice Pilot 421...

Страница 13: ...t s re o er a d set the high gas pressure to WCI WCI for LPG 5 Change the load sensor control to 250F 6 Usi g the Lo Gas Adjust e t set the lo gas pressure to WCI 8 WCI for LPG 7 Move the manometer t...

Страница 14: ...h Gas Adjust e t set the high gas pressure to WCI WCI for LPG 5 Change the load sensor control to 250F 6 Usi g the Lo Gas Adjust e t set the lo gas pressure to WCI 8 WCI for LPG 7 Move the manometer t...

Страница 15: ...d sensing control knob button in B Turn the main power switch to position 2 and continue to hold the load sensing control knob button in for 5 seconds C After 5 seconds release the knob button The con...

Страница 16: ...urner Pilot 2179 1 PTFE Bushing 6049 2 PTFE Bushing 6046 1 PTFE Bushing 6047 1 Orifices Natural Gas Description Part Qty Orifice Pilot 3225 2182 2 Orifice Zip Tube 75 2185 1 Orifice Main Burner 42 165...

Отзывы: