II
:
Usage precautions
Safety of LED
Before Use
CAUTION
• The device is a Class 1 LED product in accordance with IEC60825-1: 1993+A1:
1997+A2: 2001 and the LED used for the device is safe in expected use conditions
including situations such as looking into the LED using an optical system. However, it
is recommended to observe the following precautions when using the device:
1)Do not direct LED beams to human eyes when unnecessary.
2)Do not look into the objective lens (aperture) for a long period of time for observation.
3)If the device cannot be used properly or any device problem cannot be solved, imme-
diately stop using the device, then contact NIDEK or your authorized distributor.
WARNING
• Be sure to use a grounded power outlet.
Electric shock or fire may result in the event of malfunction or power leakage.
CAUTION
• Never use the device for other than its intended purpose.
NIDEK will not assume responsibility for accidents or malfunction caused by misuse.
• Before use of the device, read this manual. Especially, the cautions for safety and
operating procedures must be thoroughly understood. Do not use accessories that
are not specified by NIDEK for the device.
Use of the device outside the scope of the specified use may result in unexpected trou-
bles and adverse events.
• Never modify or touch the internal structure of the device.
Electric shock or malfunction may result.
• When unpacking the device, secure a sufficient space.
When the outer box is lifted to be moved, it may hit the wall, ceiling, or objects around.
• Install and use the device under the following conditions:
Ambient temperature: 10 to 35ºC (50 to 95ºF)
Humidity: 30 to 90% (Non-condensing)
Atmospheric pressure: 800 to 1,060 hPa
Protected from exposure to water
Minimal dust in the air
Protected from extraneous light sources
Level and stable surface free from vibration and bumping
The room can be darkened to the degree that a newspaper can barely be read
The reliability of image capture results is lowered, and malfunction may result. In addition,
injury may result if the device is bumped or topples over.
• Do not install the device where it is exposed to strong electromagnetic waves during
operation.
Images may not be captured properly, or malfunction may result.
Содержание AFC-330
Страница 14: ...XII...
Страница 60: ...44 BEFORE USE Labels and Symbols Common See Before Use Page II...
Страница 68: ...52 BEFORE USE Device and Software Setup...
Страница 174: ...158 MAINTENANCE Consumables and Maintenance Parts List When the lamp is replaced with a spare restock the spare...
Страница 180: ...164 SPECIFICATIONS AND ACCESSORIES Configuration...
Страница 184: ...168 EMC ELECTROMAGNETIC COMPATIBILITY...