16
MECHANICAL INSTALLATION
POWERDRIVE MD2R Installation guide
4948 - 2017.11 / d
en
2.6 - Dimensions
The cabinet-mounted
POWERDRIVE MD2R
solution is obtained by assembling cabinet modules 600 mm wide and
600 mm deep.
The table below gives the product
width (W
in mm) depending on the options incorporated:
W/o options (-B)
With options (-O)
Rating
Width
W (mm)
Load break switch
Width
W (mm)
60T to 150T
600
600
180T to 270T
1200
1200
340T to 570T
1800
1800
600T to 1100T
3600
3600
270TH to 500TH
1800
1800
600TH to 900TH
3600
3600
1400T to 1700T
1200TH to 1500 TH
Please Consult Leroy-Somer
The following options can be incorporated into the
POWERDRIVE MD2R
without affecting its dimensions:
• MD-AU1 emergency stop
• Communication modules
• Additional I/O modules
• Speed feedback modules
H
W
D = 600 mm
The table below gives the product
height (H)
depending on
the options incorporated:
Option
Height
H (mm)
POWERDRIVE MD2R standard
2100
IP21 protection
+ 0
IP54 protection
+ 100
base 100mm
+ 100
base 200mm
+ 200
base for width ≥ 2400mm (1)
+ 100
(1) Above 2400 mm long (L), a base 100 mm high should be
installed as standard to ensure the rigidity of all the cabinets.
Cables cannot be run through this base (please consult
LEROY-SOMER).
For more precise information depending on the options
chosen, use the Leroy-Somer configurator: