4.12 Battery replacement
If the built-in battery-life duration becomes short, replace the battery with one that is specificated. Be sure to use the specified battery.
Please contact us or the retailer where you purchased this product if you need it.
①
Remove the six screws on the bottom of the DT-3015N main unit, and take out the built-in battery.
②
Remove the connector and battery fixing screws.
③
Cut the insulok that is holding the battery onnector with nippers,etcs.
*Please take care not to scratch the connector cable and the battery with nippers.
④
Remove the four battery fixing screws and the top cover.
⑤
Take out the battery from the battery case, and replace with a new battery.
*Please be careful that the harness faces the outside.
⑥
Insert the Insulock attached to the battery through the Insulock through hole on the top cover.
⑦
Secure the connector cable with the Insulock so that the battery connector contacts the top cover.
(Refer to the Detail drawing) *Please tighten it strongly.
④
Attach the top cover to the battery case and fix it with the fixing screws (4 places-tightening torque 0.3 Nm).
⑤
Connect the battery connector to the main body connector.
⑩
Install the battery in the main unit and fix it with the battery case fixing screws (6 places-tightening torque 0.6 N·m).
Do not replace the battery near flammable materials.
Be sure to turn the power OFF. May result in electric shock
Battery connector
Insulok
Connector cable
Detail drawing
Top cover
Insulok through hole
Six-battery case fixing screws
Body connector
Battery case
Four-battery fixing screws