Commander S100 User Guide
59
7.2.6 Menu 6 - IO configuration
Parameter
Range
Default
P6.01 T2 Analog Input 1 Type
0-10 V (0), Digital Input (1) 0-20 mA (2), 4-20 mA No Alarm (3), 4-20 mA Hold (4),
4-20 mA Stop (5), 4-20 mA Error (6)
4-20 mA (2)
P6.02 T4 Analog Input 2 Type
0-10 V (0)
P6.03 T6 Analog Output Type
0-10 V (0), 0-20 mA (1), 4-20 mA (2)
0-10 V (0)
P6.04 T11 Digital IO 1 Type
Digital Input (0), Digital Output (1), Frequency Output (2), PWM Output (3),
DO Inverted (4)
Digital Input (0)
P6.05 T15 Digital Input 5 Type
Digital Input (0), Frequency Input (1)
Digital Input (0)
P6.06 T6 Analog Output Function Select
None (0), Ramp Input (1), Ramp Output (2), Output Frequency (3),
Output Current (4), Torque Current (5), Output Voltage (6), DC Bus Voltage (7),
T2 Analog 1 % (8), T4 Analog 2 % (9),
T15 Frequency % (10), Output Power (11), Motor RPM (12), Percentage Load (13),
PID Percentage (14), PID Error (15), Motor Thermal % (16), Drive Thermal % (17)
Ramp Output (2)
P6.07 T6 Analog Output Scaling
0.000 to 40.000
1.000
P6.08 T41-T43 Relay Function Select
None (0), Drive Running (1), At Speed (2), At Zero (3), Under Voltage (4),
External Error (5), Drive Ready (6), Drive Healthy (7), Current Limit (8),
Reverse Running (9),Current Loss (10), Threshold Detect (11)
Drive Healthy (7)
P6.09 T11 Digital Output 1 Function Select
None (0)
P6.10
T11 Frequency/
PWM Output Function Select
None (0), Ramp Input (1), Ramp Output (2), Output Frequency (3),
Output Current (4), Torque Current (5), Output Voltage (6), DC Bus Voltage (7),
T2 Analog 1 % (8), T4 Analog 2 % (9),
T15 Frequency % (10), Output Power (11), Motor RPM (12), Percentage Load (13),
PID Percentage (14), PID Error (15), Motor Thermal % (16), Drive Thermal % (17)
None (0)
P6.11 T11 Frequency/PWM Output Scaling
0.000 to 40.000
1.000
P6.12 Negative Logic (NPN Sensor) Select
Off (0) or On (1)
Off (0)
P6.13 Run/Stop Configuration
Custom (0), Run F Run Reverse (1),
Run F Run Reverse (3 Wire) (2), Run + Reverse (3),
Run + Reverse (4), Run + Jog (5), Run F Run Reverse (6),
Run + Reverse (7), Keypad (8), Enable (9), Keypad Jog (10)
Run Forward
+ Run Reverse (1)
P6.14
T2 Analog Input 1 Digital Function
Select
None (0), Hardware Enable (1), Run Forward (2), Run Reverse (3), Run Permit (4),
Forward Limit Switch (5), Reverse Limit Switch (6),
Up/Down % Increase (7), Up/Down % Decrease (8), Up/Down % Reset (9),
Ref Switch Bit 0 (10), Ref Switch Bit 1 (11), Ramp Select (12),
PID Enable (13), External Error (14), Drive Reset (15), Run (16), Reverse (17),
Jog Forward (18), Jog Reverse (19), Fire Mode (20)
None (0)
P6.15
T4 Analog Input 2 Digital Function
Select
None (0)
P6.16 T11 Digital Input 1 Function Select
None (0)
P6.17 T12 Digital Input 2 Function Select
Hardware Enable (1)
P6.18 T13 Digital Input 3 Function Select
Run Forward (2)
P6.19 T14 Digital Input 4 Function Select
Run Reverse (3)
P6.20 T15 Digital Input 5 Function Select
Ref Switch Bit 0 (10)
P6.21 T2 Analog Input 1 Minimum Input
0.00 to 100.00 %
0.00 %
P6.22
T2 Analog Input 1 Percentage at
Minimum Input
±100.00 %
0.00 %
P6.23 T2 Analog Input 1 Maximum Input
0.00 to 100.00 %
100.00 %
P6.24
T2 Analog Input 1 Percentage at
Maximum Input
±100.00 %
100.00 %
P6.25 T4 Analog Input 2 Minimum Input
0.00 to 100.00 %
0.00 %
P6.26
T4 Analog Input 2 Percentage at
Minimum Input
±100.00 %
0.00 %
P6.27 T4 Analog Input 2 Maximum Input
0.00 to 100.00 %
100.00 %
P6.28
T4 Analog Input 2 Percentage at
Maximum Input
±100.00 %
100.00 %
P6.29 T15 Frequency Input Minimum Input
0.00 to 100.00 %
0.00 %
P6.30
T15 Frequency Input Percentage at
Minimum Input
±100.00 %
0.00 %
P6.31 T15 Frequency Input Maximum Input
0.00 to 100.00 %
100.00 %
P6.32
T15 Frequency Input Percentage at
Maximum Input
±100.00 %
100.00 %