background image

Nice

PP7124

Swing gate opener

EN

  - Instructions and warnings for installation and use

Содержание PP7124

Страница 1: ...Nice PP7124 Swing gate opener EN Instructions and warnings for installation and use...

Страница 2: ...ion process handle the product with care by avoiding crushing impacts falls or contact with liquids of any kind Do not place the product near sources of heat nor expose it to open flames All these act...

Страница 3: ...ontrolled by a fire sensing system make sure that any windows larger than 200 mm are closed using the control elements Prevent and avoid any form of entrapment between the moving and fixed parts durin...

Страница 4: ...iquids keep the product away from heat sources and open flames and acid saline or potentially explosive atmospheres these may damage the product and cause malfunctions or danger ous situations if ther...

Страница 5: ...t s actual useful life Example of lifetime calculation automation of a gate with a 1 3 m long leaf weighing 180 kg for example with a solid leaf Table 1 shows the severity indices for this type of ins...

Страница 6: ...ommended 5 m 4 BLUEBUS DEVICES cable 1 cable 2 x 0 5 mm2 Maximum length 20 m note 2 5 KEY SELECTOR cable 2 cables 2 x 0 5 mm2 note 3 Maximum length 50 m 6 ELECTRIC LOCK cable 1 cable 2 x 1 mm2 Maximum...

Страница 7: ...resulting opening angle 3 with the value of distance A and the opening angle found using the graph to determine the distance B For example if A is 100 mm and the desired angle is equal to 100 distanc...

Страница 8: ...racket for the gate leaf I to the curved arm F D H F I G G H 15 10 unlock the gearmotor manually see paragraph Manually unlocking and locking the gearmotor 11 decide where to attach the bracket to the...

Страница 9: ...mit switch A as shown in the figure 4 loosen the screw that fastens the straight arm to the gear motor 5 apply the protective cover B and re tighten the screw with the washer A B 19 6 move the gate to...

Страница 10: ...nection under the Category III overvoltage conditions in accordance with the installation instructions To make the electrical connections 1 open the gearmotor s cover A A 21 2 pass the power cable and...

Страница 11: ...Example EPM EDSB ETPB For further information on the BlueBUS refer to the BlueBUS paragraph Stop Input for devices that suspend or even stop the current manoeuvre Normally Closed and Normally Open co...

Страница 12: ...EBUS L1 L2 26 The learning process of connected devices can be repeated at any time even after the installation for example whenever a device must be added to complete the new learning process refer t...

Страница 13: ...signal the current position STOP SBS OPEN BLUEBUS L1 29 To effect the manual learning procedure 1 simultaneously press and hold the and g buttons h 2 release the buttons when LED L1 starts flashing af...

Страница 14: ...on to be programmed 5 proceed for each individual position as described in the Learning in manual mode paragraph 6 repeat this last operation for all the other positions to be modified 5 4 CHECKING TH...

Страница 15: ...impact force it is neces sary to test various adjustments to find the one that gives the best results 6 2 COMMISSIONING a Commissioning can only be performed after all test ing phases have been succe...

Страница 16: ...ing will not take place if the function is disabled L3 Always Close Function ENABLED in the event of a blackout even of short duration if the control unit detects that the gate is not closed once the...

Страница 17: ...omatic Closing is enabled L2 15 seconds L3 30 seconds L4 45 seconds L5 60 seconds L6 80 seconds L7 120 seconds L8 180 seconds L2 Step by Step function L1 Open Stop Close Stop Controls the sequence of...

Страница 18: ...d M2 opens to 110 the minimum opening is 90 L2 Pedestrian 2 the M2 gate leaf opens to 1 2 of the full range L3 Pedestrian 3 the M2 gate leaf opens to 3 4 of the full range L4 Pedestrian 4 full opening...

Страница 19: ...he limit Lit for 2 seconds at the start of the opening manoeuvre Between 81 and 100 of the limit Flashes for the entire duration of the manoeuvre Exceeding 100 of the limit Flashes always 7 4 3 Verify...

Страница 20: ...uring the learning phase There may be defective devices check and replace them if necessary if changes have been made the learning procedure must be repeated 2 flashes 1 second pause 2 flashes Interve...

Страница 21: ...r to that shown in Table 8 STOP LED OFF Intervention of the STOP input Check the devices connected to the STOP input On Everything normal STOP input active Sbs LED OFF Everything normal Sbs input not...

Страница 22: ...ices can be connected to each other in parallel Any number of NC devices can be connected to each other in series Two devices with 8 2 k fixed resistor output can be connect ed in parallel if there ar...

Страница 23: ...commands shown in Table 12 Table 12 OXI IN EXTENDED MODE II No Command Description 1 Step by Step SbS Step by Step command 2 Partial opening 1 Partial opening 1 command 3 Open Open command 4 Close Cl...

Страница 24: ...p the spring G by its two ends 6 thread the other end of the cable through the hole located on the lower part of the gearmotor 7 put the cover back on A A C B G D E F 44 8 connect the cable to Kio by...

Страница 25: ...B in the appropriate slot C on the control unit s electronic board 3 insert the cable D in the appropriate slot E on the in terface C B D E A 45 4 At this stage the control unit can be powered again l...

Страница 26: ...ST NOT BE POWERED by the elec tricity grid at the same time l For information on the Solemyo system consult the relevant instruction manual To connect the Solemyo system 1 remove the cover A 2 remove...

Страница 27: ...components replace any worn parts 5 connect the power supplies again and run all the tests and checks described in the Testing paragraph PRODUCT DISPOSAL 11 11 PRODUCT DISPOSAL l This product is an in...

Страница 28: ...que 10 minutes Application limits The product can be used on gates with leaves weighing up to 200 kg for lengths up to 2 m Durability Estimated between 80 000 and 250 000 cycles depending on the condi...

Страница 29: ...cated fixing plate Operating temperature 20 C 55 C at low temperatures the gearmotor s efficiency decreases Use in highly acid saline or potentially explosive atmosphere No Protection rating IP 44 wit...

Страница 30: ...lowing directives according to the requirements envisaged for partly completed machinery Annex II part 1 section B Directive 2006 42 EC of the EUROPEAN PARLIAMENT AND COUNCIL of 17 May 2006 related to...

Страница 31: ...ENGLISH 31 NOTES...

Страница 32: ...32 ENGLISH NOTES...

Страница 33: ...uipped with back up batteries the automation can none theless be used by manually unlocking the motor consult the instructions at the end of the chapter and moving the gate leaf manually Safety device...

Страница 34: ...has come to a standstill To unlock the device 1 raise the small cover 2 insert the key A and turn it clockwise by 90 A 48 3 the gate leaf can now be moved manually to the desired position To lock the...

Страница 35: ...ENGLISH 35 NOTES...

Страница 36: ...www niceforyou com Nice SpA Via Callalta 1 31046 Oderzo TV Italy info niceforyou com IDV0668A00EN_31 01 2019...

Отзывы: