background image

II

EN

Even if your automated system satisfies regulatory safety levels, this does not 
eliminate “residue risks”, that is, the possibility of dangerous situations being 
generated, usually due to irresponsible or incorrect use. For this reason we 
would like to give you some suggestions on how to avoid these risks.

•  

Before using your automated system for the first time

, ask your fitter 

to explain how residue risks can arise and spend a few minutes reading the 

instructions and warnings for the user

 handbook that the fitter will have 

given you. Keep this manual for future use and, if you should ever sell your 
automated system, hand it over to the new owner.

ATTENTION! – Your automation is a machine that follows your com-

mand faithfully; irresponsible and improper use can make it become 

dangerous:

–  Do not command movement of the automation if there are persons, 

animals or objects within its radius of action.

–  When operating a biased-off switch, make sure that other persons 

are kept away.

–  When operating the gate, keep an eye on the automated mechanism 

and keep all bystanders at a safe distance until the movement has 

been completed.

–  It is prohibited to touch parts of the automation while the gate or the 

door is in movement!

–  The photocells are not a safety device but just an auxiliary device 

regarding safety. They are constructed with very high reliability 

technology but can, in extreme situations, undergo malfunctioning 

or even break and, in certain cases, the breakdown may not be im-

mediately evident. For this reason, when using the automation, it is 

necessary to pay attention to the following warnings:

  - Transit is only allowed when the gate or door is completely open 

with the panels at a standstill

  - IT IS PROHIBITED to transit while the gate or door is closing!

  - Periodically check the correct functioning of the photocells and 

have the envisioned maintenance checks performed at least every 6 

months.

• 

Children:

– 

This product is not intended to be used by persons (including children) 
whose physical, sensory or mental capacities are reduced, or who lack the 
necessary experience or skill.

– 

Children must not play with the appliance.

– 

Do not allow children to play with the fixed control devices of the product. 
Keep the remote controls away from children.

– 

Cleaning and maintenance to be carried out by the user must not be carried 
out by unsupervised children.

• 

Anomalies:

 if any anomalous behaviour is noticed, remove the electric pow-

er input to the plant and manually release the gear motor (see respective 
instruction manual) to make the gate function manually. Do not perform any 
self-taught repairs but request the intervention of your local installer.

• 

Maintenance:

 regular maintenance is required to keep the level of safety 

constant and guarantee the maximum duration of the entire automation 

(every 6 months). 

Any control, maintenance or repairs operation must 

only be performed by qualified staff.

– 

Before working on the system (maintenance, cleaning), always disconnect 
the product from the mains power supply.

– 

Do not operate the product if anyone is working nearby; disconnect its power 
supply before permitting such work to be done.

  Do not modify the plant and programming parameters and control 

unit regulation: your installer is responsible.

• 

The inspection, periodic maintenance and any repairs must be docu-

mented by whoever is carrying out the job

. The documents must be 

kept by the owner of the plant. The only interventions that the user can 
perform periodically are cleaning the lenses of the photocells (use a slightly 
damp soft cloth) and the removal of any leaves or stones that could block the 
automation. 

Important

 – Release the gear motor manually before proceed-

ing in order to prevent the gate being activated accidentally (see respective 
instruction book).

• 

Disposal:

 at the end of the automation’s life span, make sure that it is dis-

posed of by qualified staff and that the materials are re-cycled or disposed of 
in compliance with the Standards valid at a local level.

• 

Breakage or power cut:

 while waiting for the intervention of your installer 

or the return of the power input, if the plant does not have buffer batteries, 
the automation can be used all the same: the gear motor must be released 
manually (see the dedicated paragraph successively) and move the gate 
panel manually as desired.

RELEASE AND BLOCK THE GEAR MOTOR MANUALLY

The gear motor has a mechanical system that allows to open and close the 
gate manually.
These manual operations must be performed if there is a power cut or function-
ing anomalies.

Instructions and cautions for the user of the gear motor 

MEA2 Type KEY-Operated Release

MEA3 Type Lever-Operated Release

1

Pull down the lock cover.

1

2

1

2

2

Insert the key and r otate 
it 90° clockwise.

3

Move the gate manually.

WARNING! – To restore 

automatic operation, 

relock the gate with the 

key (rotate the key 90°, 

counterclockwise).

3

Содержание MFAB3000

Страница 1: ...ni ed avvertenze per l installazione e l uso FR Instructions et avertissements pour l installation et l utilisation ES Instrucciones y advertencias para la instalaci n y el uso DE Installierungs und G...

Страница 2: ...to prevent any form of risk INSTALLATION WARNINGS Prior to installing the drive motor check that all mechanical compo nents are in good working order and properly balanced and that the automation mov...

Страница 3: ...PH A MFAB3000 MFAB3010 MFAB3000L MFAB3000 110 MFAB3024 2 5 3 3 5 0 300 400 500 600 Max length of leaf m Max weight of leaf kg MFAB3024HS 1 5 2 5 2 3 0 100 200 300 Max length of leaf m Max weight of le...

Страница 4: ...fety sys tems and mechanical stops are in good working order 8 make sure that the screw connections are properly tightened 9 clean the inside of the box and make sure that the drain operates properly...

Страница 5: ...t type Electric gearmotor for swing gates Model Type MFAB3024 MFAB3000 MFAB3000L MFAB3000 110 MFAB3010 MFAB3024HS Accessories No accessory The undersigned Roberto Griffa as Chief Executive Officer her...

Страница 6: ...ruttore o dal suo servizio di assistenza tecnica o comunque da una persona con qualifica similare in modo da prevenire ogni rischio AVVERTENZE INSTALLAZIONE Prima di installare il motore di movimentaz...

Страница 7: ...3 GRAFICO A MFAB3000 MFAB3010 MFAB3000L MFAB3000 110 MFAB3024 2 5 3 3 5 0 300 400 500 600 Lunghezza max anta m Peso max anta kg MFAB3024HS 1 5 2 5 2 3 0 100 200 300 Lunghezza max anta m Peso max anta...

Страница 8: ...dotto nei rifiuti domestici Eseguire quindi la raccolta separata per lo smaltimento secondo i metodi previsti dai regolamenti vigenti sul vostro territorio oppure riconsegnare il prodotto al venditore...

Страница 9: ...8 1 5 10 1 5 11 Il produttore si impegna a trasmettere alle autorit nazionali in risposta ad una moti vata richiesta le informazioni pertinenti sulla quasi macchina mantenendo impre giudicati i propri...

Страница 10: ...tra vaux sur l automatisme d brancher l alimentation lectrique avant de permettre la r alisation de ces travaux Tout c ble d alimentation d t rior doit tre remplac par le fabri cant ou par son service...

Страница 11: ...GRAPHIQUE A MFAB3000 MFAB3010 MFAB3000L MFAB3000 110 MFAB3024 2 5 3 3 5 0 300 400 500 600 Longueur max battant m Poids max battant kg MFAB3024HS 1 5 2 5 2 3 0 100 200 300 Longueur max battant m Poids...

Страница 12: ...ns et recommandations destin es l utilisateur de l op rateur 4 ouvrir manuellement le portail sur toute sa course 5 v rifier que le portail ne pr sente pas de points de frottement durant le mouvement...

Страница 13: ...ails battants Mod le Type MFAB3024 MFAB3000 MFAB3000L MFAB3000 110 MFAB3010 MFAB3024HS Accessoires Aucun accessoire Le soussign Roberto Griffa en qualit de Chief Executive Officer d clare sous son ent...

Страница 14: ...limentaci n antes de realizar estas tareas Si el cable de alimentaci n est da ado debe ser sustituido por el fabricante o por el servicio de asistencia t cnica o por una persona con una calificaci n s...

Страница 15: ...no 4 3 GR FICO A MFAB3000 MFAB3010 MFAB3000L MFAB3000 110 MFAB3024 2 5 3 3 5 0 300 400 500 600 Longitud m x hoja m Peso m x Hoja kg MFAB3024HS 1 5 2 5 2 3 0 100 200 300 Longitud m x hoja m Peso m x Ho...

Страница 16: ...no presente puntos de fricci n 6 controle que la puerta detenida en cualquier punto y desbloqueada no tienda a moverse 7 controle que los sistemas de seguridad y los topes mec nicos est n en buenas c...

Страница 17: ...po MFAB3024 MFAB3000 MFAB3000L MFAB3000 110 MFAB3010 MFAB3024HS Accesorios Ninguno accesorio El abajo firmante Roberto Griffa en calidad de Chief Executive Officer bajo su propia responsabilidad decla...

Страница 18: ...ng die Automatisierung kon trollieren und Personen solange fernhalten bis die Bewegung ab geschlossen ist Bet tigen Sie das Produkt nicht wenn in der N he Personen an der Automatisierung arbeiten tren...

Страница 19: ...3000 MFAB3010 MFAB3000L MFAB3000 110 MFAB3024 2 5 3 3 5 0 300 400 500 600 H chstl nge Torfl gel m H chstgewicht Torfl gel kg MFAB3024HS 1 5 2 5 2 3 0 100 200 300 H chstl nge Torfl gel m H chstgewicht...

Страница 20: ...ff ner vom Torfl gel entriegeln wie in Kapitel Anweisungen und Hinweise f r den Benutzer des Tor ffners gezeigt 4 das Tor von Hand ganz ffnen 5 pr fen dass das Tor w hrend der Bewegung nicht durch Re...

Страница 21: ...FAB3000 MFAB3000L MFAB3000 110 MFAB3010 MFAB3024HS Zubeh r Kein Zubeh r Der Unterzeichnende Roberto Griffa in seiner Funktion als Chief Executive Officer er kl rt auf eigene Verantwortung dass die obe...

Страница 22: ...Materia opakowaniowy podlega utylizacji zgodnie z lokalnymi prze pisami Osoby trzecie nie powinny si znajdowa w pobli u bramy podczas jej przesuwania przy u yciu element w sterowniczych Podczas wykon...

Страница 23: ...EMAT A MFAB3000 MFAB3010 MFAB3000L MFAB3000 110 MFAB3024 2 5 3 3 5 0 300 400 500 600 Maksymalna dlugo skrzydla m Waga max skrzydla kg MFAB3024HS 1 5 2 5 2 3 0 100 200 300 Maksymalna dlugo skrzydla m W...

Страница 24: ...iadomy jest ewentualnego niebezpiecze stwa Odbi r MFAB wykona wed ug poni szej procedury 1 zamkn bram 2 odci zasilenie od centrali 3 zablokowa si ownik tak jak podano w Rozdzia Instrukcje i ostrze eni...

Страница 25: ...24 MFAB3000 MFAB3000L MFAB3000 110 MFAB3010 MFAB3024HS Akcesoria Nie urz dzenia Ja ni ej podpisany Roberto Griffa jako Chief Executive Officer deklaruj na w asn odpowiedzialno e wy ej wymienione produ...

Страница 26: ...t product niet als er personen in de buurt zijn die werk zaamheden op de automatisering uitvoeren koppel de elektrische voeding los alvorens deze werkzaamheden te laten uitvoeren Als de voedingskabel...

Страница 27: ...3 GRAFIEK A MFAB3000 MFAB3010 MFAB3000L MFAB3000 110 MFAB3024 2 5 3 3 5 0 300 400 500 600 Max langer vleugel m Max gewicht vleugel kg MFAB3024HS 1 5 2 5 2 3 0 100 200 300 Max langer vleugel m Max gewi...

Страница 28: ...is aangegeven in het Hoofdstuk Aanwijzingen en aanbevelingen bestemd voor de gebruiker van de reductiemotor 4 zet de poort handmatig helemaal open 5 controleer dat de poort tijdens de manoeuvre nerge...

Страница 29: ...che reductiemotor voor draaipoorten Model Type MFAB3024 MFAB3000 MFAB3000L MFAB3000 110 MFAB3010 MFAB3024HS Accessoires Geen uitrustingen Ondergetekende Roberto Griffa verklaart onder eigen verantwoor...

Страница 30: ......

Страница 31: ...EN OPERATION MANUAL IT MANUALE D USO FR GUIDE DE L UTILISATEUR ES MANUAL DE USO DE GEBRAUCHSANLEITUNG PL INSTRUKCJA OBS UGI NL GEBRUIKSHANDLEIDING I EN IT FR ES DE PL NL...

Страница 32: ...out by unsupervised children Anomalies if any anomalous behaviour is noticed remove the electric pow er input to the plant and manually release the gear motor see respective instruction manual to mak...

Страница 33: ...alimentazione elettrica all impianto ed eseguire lo sbloc co manuale del motoriduttore vedere rispettivo manuale istruzioni per far funzionare manualmente il cancello Non effettuare alcuna riparazione...

Страница 34: ...sans surveillance Anomalies en cas d un comportement anormal quelconque de l auto matisation d brancher l alimentation lectrique de l installation et effectuer le d blocage manuel du motor ducteur voi...

Страница 35: ...tamiento an malo del automatis mo quite la alimentaci n el ctrica de la instalaci n y bloquee manualmente el motorreductor v ase el respectivo manual de instrucciones para hacer funcionar manualmente...

Страница 36: ...er erwachsenen Person beaufsichtigt werden St rungen Wenn Sie ein ungew hnliches Verhalten des Torantriebs be merken trennen Sie die Anlage von der Stromversorgung und f hren Sie die manuelle Entriege...

Страница 37: ...wnik nie po winna by wykonywana przez dzieci pozbawione opieki Nieprawid owo ci je li zauwa y si jakiekolwiek nieprawid owe zacho wanie automatu nale y od czy zasilanie elektryczne od instalacji i r c...

Страница 38: ...tateerd wordt neem dan de elektrische voeding naar de instal latie weg en verricht de manuele deblokkering van de reductiemotor zie de respectievelijke handleiding met instructies om het hek manueel t...

Страница 39: ......

Страница 40: ...ISTMER02 4865_24 05 2016 www niceforyou com Nice SpA Oderzo TV Italia info niceforyou com...

Отзывы: