 Basic installation and programming manual

SwingSmart

 CNX

SwingSmart CNX 20

Swing gate operator

Содержание HySecurity SwingSmart CNX 20

Страница 1: ...EN Basic installation and programming manual SwingSmart CNX SwingSmart CNX 20 Swing gate operator...

Страница 2: ...NX Hy5B Module 34 Relay Outputs Basic 35 OXI Installation and Programming 36 SwingSmart CNX 20 For Installation manuals replacement part instructions part diagrams and more visit support hysecurity co...

Страница 3: ...not avoided COULD result in DEATH or SERIOUS INJURY CAUTION Indicates a hazardous situation which if not avoided COULD result in MINOR or MODERATE INJURY NOTICE Addresses practices not related to per...

Страница 4: ...regulations that regulate automated gate system design and installation GENERAL SAFETY INFORMATION A gate operator is only a component in a gate system The other parts of the gate system can include t...

Страница 5: ...with one to four single family dwellings Class II Class II Intended for use in a commercial location or building such as a multi family housing units five or more single family units hotels garages re...

Страница 6: ...the line of sight of the gate The Stop and or Reset button must be located in the line of sight of the gate Activation of the reset control shall not cause the operator to start A minimum of two 2 WAR...

Страница 7: ...all not come in contact with a moving vehicular access gate A pedestrian gate shall not be incorporated into an automated vehicular gate panel Any non automated gate that is to be automated shall be u...

Страница 8: ...rapment is possible up to 6 ft 1 83 m above grade Such locations occur if during any point in travel The gap between the bottom of a moving gate and the ground is greater than 4 inches 101 6 mm and le...

Страница 9: ...inch Points 6 Arm Movement SECURE PUBLIC Installers must identify all potential entrapment zones and install sensors that protect these areas SAFETY REQUIREMENTS WIRED EDGE SENSOR PHOTOEYE PHOTOEYE PO...

Страница 10: ...ower to OFF The motor disengages to stop it from running if an open or close input is activated The Motor Disengaged warning appears on the display To manually open the gate follow these steps 1 Use t...

Страница 11: ...ontroller allows the installer to independently vary the open and close speed settings Intelligent Inherent Entrapment Sensor IES Any impediment to gate travel is sensed by the system stopping gate mo...

Страница 12: ...f Cover keys g Top cap top cap shield and zip ties h Optional 208 230VAC and 24VDC voltage labels 3 Lift operator using lift handles Rear Cover Front Cover Lift Handle Note You can mark the slots cond...

Страница 13: ...sure X and Y from the output shaft center and use Table 3 to calculate Xg A and B 8 Mark Xg on the gate Figure 3 9 Route the earth ground wire and connect it to the earth ground lug Note Use these tab...

Страница 14: ...12 3 8 X 7 CUTOUT FOR CONDUITS OUPTUT SHAFT CENTER 17 43 2 cm 6 3 16 15 7 cm 12 3 8 31 4 cm 3 16 0 5 cm 7 17 8 cm PROVISIONS FOR QTY 4 1 2 13 X 3 1 2 CONCRETE ANCHORS SLOTS ALLOW 3 8 ADJUSTMENT FORWAR...

Страница 15: ...ONTROL WIRES LOW VOLTAGE COMMUNICATION WIRES PRIMARY SECONDARY WIRES OPTIONAL EARTH GROUND CONDUIT 3 FOOT 91cm MAXIMUM Earth Ground rod wire Consult local codes for proper depth The potential for ligh...

Страница 16: ...urity but increases the risk of damage to the operator in the event of a gate strike Figure 15 and Figure 16D Note Straighten the arm instead of overtightening the taper clamp for increased security 1...

Страница 17: ...Top RH LOOSEN TIGHTEN TAPER CLAMP WRENCH TAPER CLAMP BOLT Figure 9 Taper Clamp Bolt and Taper Clamp Wrench Figure 10 Operator Arm to Taper Clamp 90 90 A Correct Geometry B Incorrect Geometry C Bent E...

Страница 18: ...it sensor under the target magnet Hold the limit sensor bracket in place and tighten the bolt 5 Move the gate to the OPEN position 6 Center the open limit sensor under the target magnet and tighten th...

Страница 19: ...THE LIMIT SENSORS 1 2 3 5 7 8 6 4 RIGHT HAND LIMIT SENSOR BRACKETS AT 3 7 1 2 3 4 5 7 8 6 L2 L1 LEFT HAND LIMIT SENSOR BRACKETS AT 1 5 L2 L1 TARGET MAGNET AT 1 OPEN TARGET MAGNET AT 7 OPEN TARGET MAG...

Страница 20: ...cket is underneath the gasket groove in the back cover Figure 24 3 Install M6 hex bolts at the front cover latch posts Figure 25 Note These bolts are critical to cover fit and security of the front co...

Страница 21: ...amp wrench to turn the taper clamp bolt clockwise until the bolt becomes difficult to turn 5 To test taper clamp slip push the end of the gate with 50 75 pounds of force to simulate a gate strike 6 If...

Страница 22: ...versus Run AC Power 14 gauge wire 12 gauge wire 10 gauge wire One operator 115V 485 ft 147 m 775 ft 236 m 1235 ft 376 m Two operators 115V 242 ft 73 m 387 ft 117 m 617 ft 188 m Table 6 Wire Gauge vers...

Страница 23: ...solar installations remove the power switch mounting plate and disconnect the red V and blue V wires from the power supply Tape or wire nut the ends separately to prevent shorts Figure 38 Note CNX op...

Страница 24: ...2 HS 2 Can connect to expansion module 13 HS 1 Harness connects communication to drive module 14 RS485 15 T4 Port 16 Ethernet CONTROLLER CONNECTIONS 17 USB Used for software updates fault log download...

Страница 25: ...D Indicates gate operator status a Flashing Red An Alert Fault or Error has occurred Immediately shut down the machine and correct the fault b Solid Red Operator is in Menu Mode c Flashing Green Opera...

Страница 26: ...to select YES let the scan complete and press BACK until gate status appears on the display HYSECURITY B 1 00 MM DD YY HH MM SET CLOCK 1 2 3 4 USAGE CLASS 0 1 RIGHT 2 LEFT GATE HANDING HYSECURITY GAT...

Страница 27: ...n learn limits mode Installer must then reset open and close positions FACTORY DEFAULTS Set to 1 to erase all installer entered settings and return to factory defaults OPERATOR TYPE Factory set Used o...

Страница 28: ...to make sure there are no problems with gate travel and open close stops 4 Install a communication wire between the two operators Match A A B B and COM COM Install the grounding wire on only one of t...

Страница 29: ...ect Loop Wires Green Hy5C Mode Red Active Call Red See Display Status MX4621 www hysecurity com Gate operator menu options Sensitivity and boost Frequency Motorcycle detection Loop health scores Hy5C...

Страница 30: ...8 8 8 DNS 1 IPV4 XX X X X 8 8 4 4 DNS 2 IPV4 XX X X X fec0 2 IPV6 ADDRESS XXXX X 64 SUBNETLEN IPV6 1 128 SUBNETLEN IPV6 0 OFF 1 ON USB OPTIONS MENU SAVE ALL DATA CLEAR ALL DATA RESTORE SETUP 0 NO 1 Y...

Страница 31: ...Use with HySecurity Operators Mfg Part Mfg Details 10k or 4 Wire Pulsed Hysecurity Part Photo Eyes Retrore ective E3K R10K4 NR 1 Omron 40 ft max range limit 10k MX000999 NIR 50 325 EMX 45 ft max range...

Страница 32: ...1 0760 AS1501 0790 CPT210 2U T2 Miller Edge 10k resistor termination replace with length requirement in feet 10k Edge Wireless Kits iGAZE RE Kit Transmitter Solutions 50 ft line of sight max range lim...

Страница 33: ...DOWN arrow to choose an IES SENSITIVITY press SELECT to update the setting Note Settings 0 8 are adaptive and setting 9 is fixed WARNING Avoid setting the IES sensitivity to a fixed level 9 setting T...

Страница 34: ...Sensitivity and boost Frequency Motorcycle detection Loop health scores Hy5C TM Fully Automatic Vehicle Detector Connect Loop Wires Green Hy5C Mode Red Active Call Red See Display Status MX4621 www h...

Страница 35: ...N MODULE KIT FROM HS 2 ON THE SMARTCNX CONTROLLER TO HS A ON THE I O EXPANSION MODULE RELAY 4 11 LOGIC The three relays on the SmartCNX Controller are configurable to perform a wide range of options f...

Страница 36: ...r fobs 7 Press MENU until gate status displays 8 Press the buttons on the fob to test operation Remove a single fob in hand 1 Open OXI RADIO MENU OPTIONS steps 4 6 to install OXI 2 Press the UP or DOW...

Страница 37: ...MMUNICATIONS and press SELECT 8 Press the UP or DOWN arrow to navigate to BLE OPTIONS MENU and press SELECT 9 Press the UP or DOWN arrow to select 1 ON and press SELECT 10 Press the UP or DOWN arrow t...

Страница 38: ...fer to DC Battery Replacement on page 38 Figure 56 Fuse Replacement DC BATTERY REPLACEMENT HySecurity provides a one year warranty from the date of shipment for all batteries supplied with the SwingSm...

Страница 39: ...FW while the firmware loads It could take up to 10 minutes to load the firmware NOTICE Do not shut off power Do not remove the USB or HSP1 communication cable during download This can cause SmartCNX C...

Страница 40: ...e Pressing RESET button below display Gate binding wind or a faulty edge sensor can cause a false alert Emergency Close or Fire Open input activation will also stop the gate in Entrapment Mode Refer t...

Страница 41: ...when battery voltage has dropped to less than 21V At this level batteries have about 10 charge Gate will automatically open or close depending upon setting chosen No additional automatic function is...

Страница 42: ...to move Loose taper clamp Arm assembly binding Failed limit switch 1 Tighten taper clamp 2 Check limit sensors and replace as required 3 Verify arm condition ALERT 7 FREQ SHIFT FAULT Hy5B detects a fr...

Страница 43: ...DC UPS batteries need to be replaced Buzzer will chirp every minute until UPS batteries are replaced Batteries are not taking a charge properly Replace the 24VDC UPS batteries ALERT 22 INTLOCK FAILURE...

Страница 44: ...R 1 OR SENSOR 2 COM 2 Correct malfunctioning monitored sensor FAULT 4 GATE NO LOAD SmartCNX Controller detects no load on operator Gate is non operational while this fault is triggered Motor wires dis...

Страница 45: ...Primary Secondary communication cable installed in same conduit as high voltage AC power One operator is powered off Different software versions between operators Check software version currently load...

Страница 46: ...RROR 7 MENU CHECKSUM Software issue exists that may require factory reset Corrupt software or data Call HySecurity Technical Support for assistance ERROR 8 RPM SENSOR RPM sensor disconnected Motor Enc...

Страница 47: ...s For an exit only system the FREE EXIT loop is replaced by an INSIDE OBSTRUCTION loop FREE EXIT loop is replaced by an INSIDE OBSTRUCTION loop SECURE SIDE C D E F CENTER LOOP FREE EXIT or INSIDE OBST...

Страница 48: ...E OBSTRUCTION loop the FREE EXIT loop is replaced by an INSIDE OBSTRUCTION loop SECURE SIDE C D E F CENTER LOOP FREE EXIT or INSIDE OBSTRUCTION LOOP NOTE A minimum of three 3 detectors are required fo...

Страница 49: ...ing the force or the limit of travel retest the gate operator Failure to adjust and retest the gate operator properly can increase the risk of injury or death 4 V ri ez le fonctionnement de l ouvre ba...

Страница 50: ...otections sont fournies pour les galets expos s 2 4 The operator is intended for installation only on gates used for vehicles Pedestrians must be supplied with a separate access opening The pedestrian...

Страница 51: ...arr t le bouton de r enclenchement ou ces deux boutons doivent tre situ s dans le champ de visibilit de la barri re L activation des commandes de r enclenchement ne doit pas mettre en marche l ouvreba...

Страница 52: ...gnals are not obstructed or impeded by building structures natural landscaping or similar obstruction A wireless device shall function under the intended end use conditions c Un dispositif sans l comm...

Страница 53: ...53 MX4777 Rev D 2021 Page intentionally left blank...

Страница 54: ...stalled maintained or used improperly or contrary to instruc ons 2 subjected to negligence accident vandalism or damaged by severe weather wind ood re terrorism or war or 3 damaged through improper op...

Страница 55: ...ith black powder coated chassis High impact copolymer cover ETL Listed UL 325 Usage Class I II III IV Warranty 5 year 7 year single family residential w product registration The actual number of gate...

Страница 56: ...Nice North America HySecurity Gate Barrier Division 6705 S 209th St Ste 101 Kent WA 98032 hysecurity com MX4777 REV D 08 10 2021...