SYSTEM DIAGRAM
S1255 consists of a heat pump, water heater, electrical
module, circulation pumps and a control system. S1255
is connected to the brine and heating medium circuits.
In the heat pump evaporator, the brine (water mixed
with anti-freeze, glycol or ethanol) releases its energy
to the refrigerant, which is vaporised in order to be
compressed in the compressor. The refrigerant, of which
the temperature has now been raised, is passed to the
condenser where it gives off its energy to the heating
medium circuit and, if necessary, to the water heater.
If there is a greater need for heating/hot water than the
compressor can provide there is an integrated immersion
heater.
XL 1 6
3
7
2
4
Connection, heating medium flow
XL1
Connection, heating medium return
XL2
Connection, cold water
XL3
Connection, hot water
XL4
Connection, brine in
XL6
Connection, brine out
XL7
Dimensions and pipe
connections
560
440
70
1
800
650*
20-50
650*
600
60
135
210
390
465
540
25
622
622
600
560
440
70
1
800
650*
20-50
25
60
135
210
390
465
540
650*
XL1
XL6
XL7
XL4
XL3
XL2
PIPE DIMENSIONS
16
kW
12
kW
6
kW
Connection
28
22
(mm)
(XL1)/(XL2) Heating medium
supply/return ext. Ø
22
(mm)
(XL3)/(XL4) Cold/hot water Ø
28
(mm)
(XL6)/(XL7) Brine in/out ext. Ø
* Can be angled for side connection.
NIBE S1255
Chapter 4 | Pipe connections
14
Содержание S1255-12
Страница 1: ...IHB EN 2001 2 531086 INSTALLER MANUAL Ground source heat pump NIBE S1255...
Страница 88: ......
Страница 89: ......