Electrical data
1X230 V
S1155PC-6
230V ~ 50Hz
Rated voltage
15(16)
A
rms
Max operating current including 0 – 0.5 kW immersion heater (Recommended fuse rating).
20(20)
A
rms
Max operating current including 1 – 1.5 kW immersion heater (Recommended fuse rating).
24(25)
A
rms
Max operating current including 2 – 2.5 kW immersion heater (Recommended fuse rating).
31(32)
A
rms
Max operating current including 3 – 4 kW immersion heater (Recommended fuse rating).
33(40)
A
rms
Max operating current including 4.5 kW immersion heater (Recommended fuse rating).
0.5/1/1.5/2/2.5/3
/3.5/4/4.5
kW
Additional power
3X400 V
S1155PC-6
400V 3N ~ 50Hz
Rated voltage
12(16)
A
rms
Max operating current including 0 kW immersion heater (Recommended fuse rating).
16(16)
A
rms
Max operating current including 0.5 – 6.5 kW immersion heater (Recommended fuse rating).
0.5/1/1.5/2/2.5/3
/3.5/4/4.5/5/5.5/6/6.5
kW
Additional power
67