Service actions
HELPING THE CIRCULATION PUMP TO
START
1.
Shut off FLM S45.
2.
Remove the front cover
3.
Remove the fan.
4.
Loosen the venting screw (QM5) with a screwdriver.
Hold a cloth around the screwdriver blade as a small
amount of water may run out.
5.
Insert a screwdriver and turn the pump motor
around.
6.
Screw in the venting screw (QM5).
7.
Start FLM S45 and check that the circulation pump
is working.
It is often easier to start the circulation pump with
FLM S45 running. If the circulation pump is helped to
start with FLM S45 running, be prepared for the
screwdriver to jerk when the pump starts.
LEK
Luftningsskruv
Vent screw (QM5)
NIBE FLM S45
Chapter 8 | Service
28
8 Service