General
F2030 is equipped with an internal electronic control
that handles those functions that are necessary for
operation of the heat pump, for example defrosting,
stop at max/min temperature, connection of the
compressor heater as well as enabling the heater for
the condensation watering trough and monitoring of
pressure switches.
The temperatures, number of starts and the operating
time can also be read.
The integrated controller is set during installation and
can be used during a service.
Under normal operating conditions the home owner
does not need to have access to the controller.
F2030 has an integrated return line sensor that limits
the return temperature.
F2030 can also be switched on/off via signals from
other control equipment or a thermostat. If F2030 is
controlled from a NIBE indoor module (accessory) the
control is described in the instructions supplied.
F2030 communicates with NIBE SMO or the indoor
module which means that settings and measurement
values from F2030 can be adjusted and read off in the
indoor module.
Navigation
LP
HP
34
NO
O/C
NC
Hjälpkontaktor
(ingår ej vid leverans)
12 – 230V
15
88
90
86
41
33
89
93
34
91
Plus button
The plus button (S1) is used to browse
through the channel system (forwards) or
raise the value of the selected parameter.
See the section “Control” – “Channel descrip-
tion”
Minus button
The minus button (S2) is used to browse
through the channel system (backwards) or
lower the value of the selected parameter.
See the section “Control” – “Channel descrip-
tion”
Enter button
The Enter button (S3) is used to activate and
confirm value changes.
See the section “Control” – “Channel descrip-
tion”
To modify a value, first press the Enter button to activ-
ate modification mode, the value flashes. Adjust the
value as required using the Plus button or Minus but-
ton. Holding the Plus button or Minus button in for
about 3 seconds speeds up the change in value. Then
confirm using the Enter button. The value will stop
flashing.
The instructions are divided into three parts: status,
temperatures and adjustable values.
Quick movement between the different types is carried
out by pressing the enter button when STATUS, TEMP.
or ADJUST. are displayed.
NIBE™ F2030
Chapter 7 |
Control - Introduction
26
7 Control - Introduction
Содержание F2030
Страница 1: ...Installer manual LEK NIBE F2030 Air water heat pump IHB GB 1540 4 231115...
Страница 2: ......
Страница 13: ...Removing the side cover LEK APH 11 Chapter 2 Delivery and handling NIBE F2030...
Страница 32: ...5 The temperature on the flow temperature sensor falls below 4 C NIBE F2030 Chapter 7 Control Introduction 30...
Страница 48: ...Electrical circuit diagram NIBE F2030 Chapter 11 Technical data 46...
Страница 49: ...47 Chapter 11 Technical data NIBE F2030...
Страница 50: ...NIBE F2030 Chapter 11 Technical data 48...
Страница 51: ...49 Chapter 11 Technical data NIBE F2030...
Страница 54: ......