Activating ERS S10 can be performed via the start guide
or directly in the menu system.
Caution
Also see the Installer Manual for the main
product.
Start guide
The start guide appears upon first start-up after heat
pump installation, but is also found in menu 5.7 .
Menu system
If you do not make all settings via the start guide or need
to change any of the settings, this can be done in the
menu system.
MENU 5.2.4 -SYSTEM SETTINGS
Activating/deactivating of accessories.
Select: "exhaust/supply air module".
MENY 5.3.12 - EXHAUST/SUPPLY AIR
MODULE
months btwn filter alarms
Setting range: 1 – 24
Default value: 3
lowest extract air temp.
Setting range: 0 – 10 °C
Default value: 5 °C
bypass at excess temperature
Setting range: 2 – 10 °C
Default value: 4 °C
bypass during heating
Setting range: on/off
Factory setting: off
cut-out val. exh. air temp.
Setting range: 5 – 30 °C
Default value: 25 °C
product
Setting range: ERS S10, ERS 20/ERS 30
Factory setting: ERS 20 / ERS 30
action level monitor
Setting range: off, blocked, level monitor
Default value: level monitor
months btwn filter alarms
: Set how often the filter alarm
is to be displayed.
lowest extract air temp.
: Set the minimum extract air
temperature to prevent the build-up of ice on the heat
exchanger. The supply air fan speed reduces, if the ex-
tract air temperature (BT21) is lower than the set value.
bypass at excess temperature
: If a room sensor is in-
stalled, you set the over-temperature at which the by-
pass damper (QN37) will open here.
bypass during heating:
Activate whether the bypass
damper (QN37) will also be allowed to open during heat
production.
cut-out val. exh. air temp.:
If no room sensor is installed,
you set the exhaust air temperature at which the bypass
damper (QN37) will open here.
product:
Here, you set which ERS model is installed.