Ci2

Ci2G

contura.eu

Содержание Contura Ci2

Страница 1: ...Ci2 Ci2G contura eu ...

Страница 2: ...30 Montage 32 Fakta 3 Prestandadeklaration 4 EU försäkran om överrensstämmelse 5 Måttskiss 6 Inbyggnadsexempel 8 Montering 32 Fakta 18 Ytelseserklæring 19 EU samsvarserklæring 20 Målskisse 21 Innbyggingseksempel 23 Montering 32 Facts 10 Declaration of performance 11 EU Declaration of Confirmit 12 Dimensions diagram 13 Recess example 15 Assembly 32 ...

Страница 3: ...ed Also read the Lighting instructions before lighting for the first time The insert becomes very hot During operation certain surfaces of the insert become very hot and can cause burn injury if touched Be aware of the strong heat radiated through the hatch glass Placing flammable material closer than the safe distance indicated may cause a fire Pyre lighting can cause quick gas ignition with the ...

Страница 4: ...assification A1 Minimum distance to flammable materials Rear 200 mm Side 250 mm Ceiling 1200 mm Ceiling 700 mm front grate Front 1400 mm Floor 275 mm Fire hazard due to burning fuel falling out Pass EN 13229 2001 A2 2004 AC 2007 Cleanability Pass Emissions from combustion CO 1500 mg Nm3 13 O2 Surface temperatures Pass Temperature on the handle Pass Mechanical resistance Pass Temperature in the spa...

Страница 5: ...ture control No In standby mode elSB kW With mechanic thermostat room temperature control No With electronic room temperature control No With electronic room temperature control plus day timer No With electronic room temperature control plus week timer No OTHER CONTROL OPTIONS Room temperature control with presence detection No Room temperature control with open window detection No With distance c...

Страница 6: ...ements must be at least 1 4 metre from the front of the insert door When connecting to a steel chimney the requirements for safe distance to the chimney must also be observed A clearance of at least 300 mm must be allowed as a safe distance between an uninsulated flue pipe and com bustible building elements Dimensions diagram 3 sided frame 4 sided frame ...

Страница 7: ...nce must stand on a constructional hearth which meet the building regulations and has minimum dimension as shown in the diagram Always check that the building has enough bearing capacity for the heart stove and chimney The stove can be loaded with maximum 100 kg of chimney ...

Страница 8: ...t to the ceiling The recess must be sealed off above the convection exhaust The seal must be 100 mm above the convection exhaust s upper edge and must be made of 40 mm non flammable material according to the material requirements above Use heat resistant silicone for example between the seal and chimney Convection air The convection air ventilates the surround cools the insert and carries hot air ...

Страница 9: ...t be a 20 mm air space between the building board and the combustible wall The air space must allow air to flow freely along the lower and upper edges see diagram to the right Diagram of aerated wall Two calcium silicate board battens ensure that the air space is maintained Firewall approved and fully complies with safety requirements according to the authorised inspection body Examples of approve...

Страница 10: ...Air gap 550 40 30 275 1100 100 Area in min 300 cm2 Load bearing base Area out min 200 cm2 Combustible wall 700 min 100 20 40 40 55 100 275 1100 Area out min 200 cm2 Area in min 300 cm2 Heat shield Load bearing base 20 mm Air gap max 100 Ci2 Recess example Always observe the safety distances to combustible material required by a steel flue The dimensions are the minimum dimensions unless otherwise ...

Страница 11: ...port 2 Fire bricks Vermiculite 3 Type plate 4 Grate 5 Ash pan 6 Hearth base 7 Serial number Før montering Montage Hvis innsatsen må legges ned for å flyttes bør løse deler demonteres Demontering av brennplater og hvelv er beskrevet på neste side 1 Stussplate 2 Brennplater og hvelv Vermikulitt 3 Typeskilt 4 Rist 5 Askeskuff 6 Ildstedsbunn 7 Serienummer Les éléments non fixés devront être déposés si...

Страница 12: ...33 1 2 3 5 6 7 4 Handle with care ...

Страница 13: ...eas This when burning wood logs and operated in accordance with these instructions and when fitted with a permanent stop to prevent closure of the air control unit beyond 31 open position Mandatory for smoke control areas The permanent stop must be installed if the appliance is to be used in a smoke control area this stop must not be removed in smoke control areas otherwise an offence will be comm...

Страница 14: ...35 8 9 10 ...

Страница 15: ...36 11 12 ...

Страница 16: ...ara minst 10 mm luftspalt detta pga insatsens värmeutvidgning The insert is designed to be installed as a stove cassette in existing approved open hearths There must be an 10 mm air gap around the insert to allow for the expansion of the insert when hot L insert peut être installé comme une cassette dans un foyer ouvert existant et homologué Un espace d au moins 10 mm doit être prévu autour de l i...

Страница 17: ...38 Accessory Tilbehør Accessoire Tillbehör GB NO FR SE 1 2 3 ...

Страница 18: ...nnsatsen kan også kobles til med faste rør som føres opp i skorsteinen Raccordement à une cheminée de maçonnerie existante Pour simplifier le montage il est recommandé d utiliser un tuyau flexible proposé en option Fixez le manchon dans le tuyau Raccordez et scellez entre le tuyau et la cheminé selon les instructions séparées L insert peut également être raccordé avec des conduits fixes dans la ch...

Страница 19: ...40 3 4 ...

Страница 20: ...41 x4 5 x4 6 ...

Страница 21: ...42 7 mm 7 8 ...

Страница 22: ...43 9 10 ...

Страница 23: ...44 11 12 ...

Страница 24: ... de invändiga delarna i omvänd ordning Reinstall the internal components in reverse order Sett de innvendige delene tilbake på plass i motsatt rekkefølge Remontez les éléments intérieurs dans l ordre inverse SE GB NO FR ...

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ...811483 IAV SE EX Ci2 2 2022 05 24 NIBE AB Box 134 285 23 Markaryd Sweden contura eu ...