23
NIBE BA-SVM 10-200
5 AMS 10 outdoor unit
Delivery and handling
Installation
Lift from the street to
the set-up location
The AMS 10 heat pump must be transported and
stored vertically.
Do not place the AMS 10 heat pump directly on the
lawn or other unstable surface.
If there is a risk of snow slip from the roof, a protec-
tive roof or cover must be erected to protect the heat
pump, pipes and wiring.
If the base allows, the simplest thing is to use a pallet
truck to move the AMS 10 heat pump to the set-up
location.
If the AMS 10 heat pump needs to be transported
across soft ground, such as a lawn, we recommend
that a crane truck is used which can lift the unit to the
set-up location. When the AMS 10 heat pump is lifted
with a crane, the packaging must be undamaged and
the load evenly distributed on the boom, see the draw-
ing above.
If a crane cannot be used, the AMS 10 heat pump
can be transported using an extended hand truck.
The AMS 10 heat pump must be secured on the side
marked “heavy side” and two people are required to
set the AMS 10 in position.
• Place the AMS 10 heat pump outdoors on a solid
level base that can take the weight, preferably a
concrete foundation. If concrete slabs are used
they must rest on asphalt or shingle.
• The concrete foundation or slabs must be posi-
tioned so that the lower edge of the evaporator
is at the level of the average local snow depth;
however, no lower than 300 mm. Supports and
fastenings on the page are available in the AMS
10 manual in the “Accessories” section.
• The AMS 10 heat pump should not be positioned
next to the walls of rooms where noise could be
a problem, for example, next to a bedroom.
• Also ensure that the placement does not disturb
the neighbours.
• The AMS 10 heat pump must not be placed such
that recirculation of the outdoor air can occur.
This causes lower power and impaired efficiency.
• The evaporator should be sheltered from direct
wind, which negatively affects the defrosting func-
tion. The AMS 10 heat pump must be placed such
that the evaporator is protected from the wind.
• Large amounts of condensate, as well as melt
water from defrosting, may be produced. Conden-
sate must be drained off to a drain (see subsection
“Condensation water drain”).
• Care must be exercised so that the heat pump is
not scratched during installation.
CAUTION
Ensure that the heat pump cannot fall over during trans-
port.
CAUTION
The centre of gravity is offset to one side (see inscription
on packaging).