![Nibe AHP S300 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/nibe/ahp-s300/ahp-s300_installer-manual_1685865019.webp)
Service actions
SAFETY VALVE
The hot water coil's externally mounted safety valve
sometimes releases a little water after hot water usage.
This is because the cold water, which enters the hot
water coil, expands when heated causing the pressure
to rise and the safety valve to open.
The function of the safety valve must be checked regu-
larly. Perform checks as follows:
1.
Open the valve.
2.
Check that water flows through the valve.
3.
Close the valve.
TIP
The safety valve is not supplied with the accu-
mulator tank. Contact your installer if you are
unsure how one checks the valve.
EMPTYING
AHP S300 and AHPH S300: The vessel is drained via
docking connection (XL19).
AHPS S300: Empty the vessel via the drain valve (QM1).
AHP S300 and AHPS S300: The vessel is drained via
the drain valve (QM1) in AHPS S300, in those cases
AHP S300 and AHPS S300 are connected.
The hot water coil in AHPS S300 and AHPH S300 is
emptied through the siphon (with hose) in the cold water
connection (XL3).
Drain the solar coil in AHPS S300 through the siphon
(with hose) on the connection, return to solar heating
system (XL14).
AHP S300
XL19
AHPS S300
QM1
XL14
XL3
AHPH S300
XL3
XL19
19
Chapter 7 | Service
AHP S/ AHPS S/ AHPH S
7 Service