background image

Installer manual

AG-AC10

Air/air heat pump

IHB GB 1615-2

M11862

Содержание AG-AC10-42

Страница 1: ...Installer manual AG AC10 Air air heat pump IHB GB 1615 2 M11862...

Страница 2: ......

Страница 3: ...8 Pipe connections 9 4 Electrical connections 9 General 9 Communication cable 9 Connecting indoor and outdoor unit 10 Connecting accessories 11 5 Installation 11 Compatible model combinations 11 Insta...

Страница 4: ...where they are made IPX4 means that the product is protected against drops of water from all angles Recovery Information regarding the correct recycling of the product in accordance with the EU direc...

Страница 5: ...stallation and safety instructions exactly as described and shown Comply with local and national electrical regulations Note all the warning and safety messages indicated in this manual The unit must...

Страница 6: ...oor unit During installation in damp or uneven locations Use a base that is stable and raised above the ground to prevent damage and abnormal vibrations in locations exposed to strong winds Secure the...

Страница 7: ...illing1 1 Additional filling of refrigerant can be done when the unit is running in cooling operation For refrigerant pipe 1 4 3 8 15 g m For refrigerant pipe 1 4 1 2 20 g m For information about pipe...

Страница 8: ...AC10 42 AG AC10 50 one indoor unit Size B AG AC10 42 AG AC10 50 two indoor units Size A Size A AG AC10 50 two indoor units Size A Size B Explanation Indoor unit AG WT10 4 AG WL10 4 Size A AG WT10 7 A...

Страница 9: ...ed with an earth fault breaker the heat pump should be equipped with a separate one Incoming supply must be 230 V 50 Hz via elec trical distribution units with fuses If an insulation test is to be car...

Страница 10: ...s equipped for connection of a con densation water pipe AG CH10 Connect the power supply to AG CH10 as illustrated GREY WHITE GREEN YELLOW AG CH10 Caution Also see the Installer manual for AG CH10 AG...

Страница 11: ...T10 4 AG WL10 4 AG AC10 42 AG WT10 4 AG WL10 4 AG WT10 4 AG WL10 4 AG AC10 50 AG WT10 7 AG WL10 7 AG WT10 4 AG WL10 4 Installation instructions 1 Place the outdoor unit on a stable base raised above t...

Страница 12: ...Thread the flange nuts which are removed from the outdoor unit on the pipes and bend up the ends of the pipes NOTE Only use tools intended for R410A 7 A good upward bend must have the following prope...

Страница 13: ...rigerant pipe connect the vacuum pump to the outdoor unit as illustrated NOTE Remaining air or damp affects the heat pump sfunctionnegativelyandcandamage the product INDOOR UNIT INDOOR UNIT Indoor uni...

Страница 14: ...ak trace caps and connections using a sniffer or leak spray See page 16 for the valves main func tions Repeat steps 10 13 if you have more indoor units The indoor units must be marked with indoor unit...

Страница 15: ...partially 1 4 turns Extract air from the manometer Then close the high pressure valve fully 2 Start the climate unit in cooling mode When the pressure that is read out from the manometer has dropped t...

Страница 16: ...e unit OPEN Pressure measurement and gas filling CLOSED Vacuuming with vacuum pump The service valve on the outdoor unit that gives access to the refrigerant system is of the Schrader type Use hoses t...

Страница 17: ...Key to symbols The LED is off The LED flashes Cause DL7 DL6 DL5 DL4 DL3 Mixed up pipes Defective or disconnected temp sensor liquid pipe circuit B Defective or disconnected temp sensor liquid pipe cir...

Страница 18: ...t no 067 466 AG CH10 60 Length 6000 mm Part no 067 468 Ground stand Ground stand AG GS10 1 For installation on ground Part no 067 460 GSM module AG BU10 With AG BU10 you can control the indoor unit vi...

Страница 19: ...Dimensions AG AC10 42 50 895 830 538 15 337 285 360 307 615 630 19 Chapter 9 Technical data AG AC10 9 Technical data...

Страница 20: ...ns 6 35 1 4 mm inches Pipe connection liquid 9 52 3 8 mm inches Pipe connection gas 0 8 mm Min thickness refrigerant pipe Recommended working range 4 20 50 C Min max outdoor temp during cooling 10 32...

Страница 21: ...3 4 4 1 1 2 2 RED RED RED RRN BRN BRN WHT WHT YEL YEL ORG BLU RED BRN YEL BLU WHT ORG 1 1 2 2 1 1 2 2 1 1 2 2 1 1 2 2 3 3 1 1 2 2 3 3 BLU BLU BLU BLU BLK BLK BLK BLK BLK BLK GRY GRY WHT WHT INVERSION...

Страница 22: ...rmation 4 Installation 11 Installation instructions 11 Pump down 15 M Marking 4 P Pipe connections Condensation removal 7 Connecting the cooling circuit 7 S Safety information Marking 4 Symbols 4 Safe...

Страница 23: ......

Страница 24: ...WS name Gemensamt WS version a193 working edition Publish date 2016 05 19 15 50 37 4255 150 02 NIBE AB Sweden Hannabadsv gen 5 Box 14 SE 285 21 Markaryd info nibe se www nibe eu M11862...