3.

Power on the sub-system(s) that are on the other side of the cable link(s) of the system(s) 
that were powered on in Step 2. These sub-systems may also contain additional “mc” ports 
for cable links to other sub-systems. The item that follows power sequence C in Figure 4 
meets this criterion.

4.

Repeat Step 3 if applicable until all systems are powered on. The item that follows power 
sequence D in Figure 4 meet this criterion.

5.

Observe the front panel Link LED status on all NI PXIe-8383mc modules and all other 
products that connect the chassis and systems together via a cable link. A properly linked 
system should report a solid green status across all products that accept a cabled 
MXI-Express connection. All NI PXIe-8383mc adapter modules should report a solid 
green MC LED status wherever they are set to MC mode of operation.

Caution

The front panel LED status of the NI PXIe-8383mc may not report cases 

when systems are not properly recognized due to an improper power on sequence. 
A reboot of the system that controls the NI PXIe-8383mc may be necessary to resolve 
this.

Tip

In applications where the power sequence must be automated, consider using 

products with Wake-on-LAN features or NI chassis that have Inhibit Mode 
capability. Be sure to allow time in the sequence for the NI PXIe-8383mc to configure 
prior to powering on the sub-system that is cabled to it.

Powering Off the PXImc System

The correct power off sequence is the reverse of the power on sequence illustrated as D to A in 
Figure 4. Make sure that all data transfer applications through all PXImc Logic Blocks are 
stopped before proceeding.

Caution

Be sure to power off sub-systems that are cabled to “mc” ports of other 

systems first. Following an improper power off sequence may cause the operating 
system(s) of involved systems to hang or fail.

Note

To power off the chassis while the host computer or host chassis is on, you 

may need to hold the power button for at least four seconds.

Software Installation and Configuration

The NI PXImc-8383mc requires the NI-PXImc driver software to enable its features. Refer to 
the 

readme.html 

on the NI-PXImc driver DVD for software installation instructions. 

Содержание PXIe-8383mc

Страница 1: ...Powering Off the PXImc System 12 Software Installation and Configuration 12 Specifications 13 Worldwide Support and Services 16 About This Guide This document describes the features functions and ope...

Страница 2: ...ss PCIe The terms PCI Express and PCIe are interchangeable in this guide PXI Express chassis In this manual whenever a PXI Express chassis is referenced a CompactPCI Express chassis could be used inst...

Страница 3: ...gure 1 illustrates where the PXImc Logic Block is applied to join the Root Complexes of two systems Figure 1 PXImc System Diagram In the example shown the system on the right is designated as a PXImc...

Страница 4: ...em does not contain a PXImc Logic Block a NI PXIe 8383mc can be installed in the Primary System Host to create a Logical PXImc Device out of the sub system Tip Consolidating all NI PXIe 8383mc adapter...

Страница 5: ...3 NI PXIe 8383mc 153100x 02L Block Diagram The PXImc logic block consists of a non transparent bridge and all the associated circuitry necessary to work with clock references from both the Primary Sys...

Страница 6: ...operating the NI PXIe 8383mc in MC mode and using a NI PXIe 8384 for daisy chain purposes SW4 FACT USER Factory User Mode Switch The FACT USER switch shown in Figure 3 selects between two different me...

Страница 7: ...ion Table 1 describes the function of the front panel LEDs FACT USER Switch Factory User SW4 BAR No Size bytes Address Space Prefetchable FACT BAR 5 32M 32 bit Yes USER BAR 1 BAR 2 BAR4 BAR5 128M 64M...

Страница 8: ...grounding strap or by holding a grounded object Touch the antistatic package to a metal part of the computer chassis before removing the device from the package Remove the device from the package and...

Страница 9: ...jector rail Caution Do not raise the injector ejector handle as you insert the NI PXIe 8383mc It will not insert properly unless the handle is in its downward position so that it does not interfere wi...

Страница 10: ...nsparent bridge in the PXImc Logic Block needs time to self configure before the sub system on the other side of the cable link can connect to it Consolidating all NI PXIe 8383mc adapter modules into...

Страница 11: ...are still powered off Allow time for the operating system to begin loading before proceeding to the next step The three items that follow power sequence B in Figure 4 meet these criteria Caution Do n...

Страница 12: ...mproper power on sequence A reboot of the system that controls the NI PXIe 8383mc may be necessary to resolve this Tip In applications where the power sequence must be automated consider using product...

Страница 13: ...XIe 8384 products NI PXIe 8383mc 153100x 02L Note These specifications are typical at 25 C unless otherwise stated and are subject to change without notice Physical Dimensions 10 0 16 0 cm 3 9 6 3 in...

Страница 14: ...in accordance with IEC 60068 2 1 and IEC 60068 2 2 Meets MIL PRF 28800F Class 3 limits Relative humidity range 5 to 95 noncondensing Tested in accordance with IEC 60068 2 56 Shock and Vibration Opera...

Страница 15: ...uipment is intended for use in commercial light industrial and heavy industrial locations In Europe Canada Australia and New Zealand per CISPR 11 Class A equipment is intended for use only in heavy in...

Страница 16: ...ental information refer to the Minimize Our Environmental Impact web page at ni com environment This page contains the environmental regulations and directives with which NI complies as well as other...

Отзывы: