![NI PXIe-8135 Скачать руководство пользователя страница 67](http://html1.mh-extra.com/html/ni/pxie-8135/pxie-8135_user-manual_1685592067.webp)
A-2
|
ni.com
Appendix A
Specifications
Electrical
Physical
Board dimensions .............................................Four-wide 3U PXI Express module
Slot requirements ..............................................One system slot plus three controller expansion
slots
Compatibility ....................................................Fully compatible with
PXI Express
Specification
1.0
Weight ...............................................................1.30 kg (2.87 lb) typical
Environment
Maximum altitude.............................................2,000 m (800 mbar)
(at 25 °C ambient temperature)
Pollution Degree ...............................................2
Indoor use only.
Caution
Clean the NI PXIe-8135 with a soft nonmetallic brush. Make sure that the
device is completely dry and free from contaminants before returning it to service.
Removable Hard Drive
Yes (1)
Installed Operating System
Windows 7 Professional,
Windows XP Professional SP3 for
Embedded Systems
*
Removable hard drive option.
†
Extended-temperature 24/7 option provides 80 GB minimum hard drive. Controllers configured for
LabVIEW RT provide a 80 GB (minimum) SATA hard drive.
Voltage (V)
Current (Amps)
Typical
Maximum
+3.3 V
3.75 A
5.4 A
+5 V
1.5 A
2.0 A
+12 V
3.5 A
5.0 A
-12 V
0.00 A
0.00 A
+5 V Aux
0.3 A
0.4 A
NI PXIe-
8
135