background image

GPIB Hardware Installation Guide and Specifications

|

© National Instruments

|

27

Connector

GPIB

IEEE 488 24-pin connector (The PCI-GPIB/LP 
uses a special cable to convert between the 
Micro D-Sub connector of the board and the 
GPIB connector.)

PCI

Universal

Environment

Operating ambient temperature

0 °C to 55 °C 
(Tested in accordance with IEC 60068-2-1 and 
IEC 60068-2-2.)

Operating relative humidity

10% to 90%, noncondensing 
(Tested in accordance with IEC 60068-2-56.)

Storage ambient temperature 

-20 °C to 70 °C 
(Tested in accordance with IEC 60068-2-1 and 
IEC 60068-2-2.)

Storage relative humidity

5% to 95%, noncondensing 
(Tested in accordance with IEC 60068-2-56.)

PCI-GPIB+

Performance

GPIB

3-wire

up to 1577 kbytes/s

HS488

up to 8182 kbytes/s

Power Requirements

3.3 V

170 mA, Typical
575 mA, Maximum

Physical Characteristics

Dimensions

10.67 cm × 11.99 cm (4.2 in. × 4.7 in.)

Connector

GPIB

IEEE 488 24-pin connector

PCI

Universal

Содержание ExpressCard-GPIB

Страница 1: ...iguration 15 Firmware Update 17 READY LED Signaling 17 CFG RESET Switch 18 Specifications 19 ExpressCard GPIB 19 GPIB ENET 1000 20 GPIB USB HS 21 GPIB USB HS 22 PCI 8232 23 PCIe GPIB and PCIe GPIB 25...

Страница 2: ...o a different outlet so that the transmitter and the receiver are on different branch circuits Some hardware may require the use of a metal shielded enclosure windowless version to meet the EMC requir...

Страница 3: ...ch unit to reside at a different ground potential Use an isolated USB hub Complete the following steps to install your interface 1 Connect the USB connector from the GPIB USB interface to an available...

Страница 4: ...B USB HS is plugged into a USB full speed USB 1 1 port Amber indicates that the GPIB USB HS is plugged into a USB Hi Speed USB 2 0 port ACTIVE Indicates activity on the GPIB bus Table 2 GPIB USB HS LE...

Страница 5: ...ged in so that it remains grounded while you install the GPIB hardware 2 Remove the top cover or other access panels to gain access to the computer expansion slots 3 Find an unused expansion slot in y...

Страница 6: ...w the mounting bracket of the GPIB board to the back panel rail of the computer 7 Replace the top cover or the access panel to the expansion slot 8 Power on your computer The GPIB hardware installatio...

Страница 7: ...e differential running through your system Use a GPIB 120B Bus Isolator Expander to isolate GPIB systems and expand the GPIB interface up to 28 devices Use a pair of GPIB 140A High Speed Fiber Optic B...

Страница 8: ...B board To avoid electrostatic damage when you handle the board touch the antistatic plastic package to a metal part of your system chassis before removing the board from the package Complete the foll...

Страница 9: ...orce the board into place Figure 4 Installing the PMC GPIB 5 Use the mounting hardware provided to fasten the PMC GPIB to the host 6 Reinstall the host if you removed it to install the PMC GPIB 7 Powe...

Страница 10: ...grounded while you install your PXI card 2 Choose an unused PXI or CompactPCI 5 V peripheral slot For maximum performance your PXI card has an onboard DMA controller that can only be used if the boar...

Страница 11: ...to install your PXI card into a PXI or CompactPCI chassis Figure 5 Installing Your PXI Card 6 Screw the front panel of the PXI card to the front panel mounting rail of the PXI or CompactPCI chassis 7...

Страница 12: ...this information when you run some of the utilities 5 Contact your network administrator to determine whether your network supports DHCP or if you need to manually perform the Ethernet configuration...

Страница 13: ...ns itself an IP address in the range of 169 254 x x Refer to Auto IP Addressing for more information The time required for assigning the IP address depends on your network and the configuration of you...

Страница 14: ...linking green Indicates you have a network link and network activity is detected Off Indicates you do not have a network link Software Recognition In Windows use the GPIB Ethernet Wizard to add the GP...

Страница 15: ...le DHCP Auto IP addressing Verify or change the hostname Add or change a comment to help identify the device Change the administrator password Update firmware Once the GPIB ENET 1000 has been added to...

Страница 16: ...P address is in the form of 169 254 x x This type of addressing is useful for connecting the GPIB ENET 1000 directly to a Windows PC To determine the Auto IP address the GPIB ENET 1000 is using you ne...

Страница 17: ...dress but this number must be the same as other devices on your network if your subnet mask is 255 255 255 0 If you are setting up your own network you probably do not have a gateway or DNS server If...

Страница 18: ...esents the digit 1 in the tens column and nine long flashes represent the digit 9 in the tens column Step 2 Count the Short Flashes The long flashes are followed by shorter flashes each short flash la...

Страница 19: ...e network configuration and the GPIB ENET 1000 continues to boot normally Once the READY LED blinks yellow release the CFG RESET switch The GPIB ENET 1000 resets to its default network characteristics...

Страница 20: ...al shock 20 C to 65 C 5 shocks Shock and Vibration Nonoperating shock 50 g 11 ms Tested in accordance with IEC 60068 2 27 Nonoperating vibration sinusoidal 15 g 100 Hz to 2 000 Hz Tested in accordance...

Страница 21: ...sted in accordance with IEC 60068 2 1 and IEC 60068 2 2 Storage relative humidity 5 to 95 noncondensing Tested in accordance with IEC 60068 2 56 Shock and Vibration Operating shock 30 g peak half sine...

Страница 22: ...g Jackscrew Thread M3 5 0 6 Torque 0 56 N m 5 0 lb in maximum Environment Operating ambient temperature 0 C to 55 C Tested in accordance with IEC 60068 2 1 and IEC 60068 2 2 Operating relative humidit...

Страница 23: ...pe A plug Jackscrew Thread M3 5 0 6 Torque 0 56 N m 5 0 lb in maximum Environment Operating ambient temperature 0 C to 55 C Tested in accordance with IEC 60068 2 1 and IEC 60068 2 2 Operating relative...

Страница 24: ...eight 102 g 3 6 oz Connector GPIB IEEE 488 24 pin connector Ethernet RJ 45 with integrated LEDs Environment Operating ambient temperature 0 C to 55 C Tested in accordance with IEC 60068 2 1 and IEC 60...

Страница 25: ...temperature 0 C to 55 C Tested in accordance with IEC 60068 2 1 and IEC 60068 2 2 Operating relative humidity 10 to 90 noncondensing Tested in accordance with IEC 60068 2 56 Storage ambient temperatu...

Страница 26: ...mensions PCI GPIB TNT4882C 13 3 cm 10 7 cm 5 25 in 4 20 in PCI GPIB TNT5004 12 cm 6 44 cm 4 72 in 2 54 in PCI GPIB LP 12 cm 6 44 cm 4 87 in 2 54 in 1 PCI GPIB boards manufactured before 2003 use the T...

Страница 27: ...C 60068 2 2 Operating relative humidity 10 to 90 noncondensing Tested in accordance with IEC 60068 2 56 Storage ambient temperature 20 C to 70 C Tested in accordance with IEC 60068 2 1 and IEC 60068 2...

Страница 28: ...ent temperature 20 C to 70 C Tested in accordance with IEC 60068 2 1 and IEC 60068 2 2 Storage relative humidity 5 to 95 noncondensing Tested in accordance with IEC 60068 2 56 PMC GPIB Performance GPI...

Страница 29: ...ted in accordance with IEC 60068 2 1 and IEC 60068 2 2 Storage relative humidity 5 to 95 noncondensing Tested in accordance with IEC 60068 2 56 PXI 8232 Performance GPIB 3 wire up to 1536 kbytes s HS4...

Страница 30: ...95 noncondensing Tested in accordance with IEC 60068 2 56 Shock and Vibration Operating shock 30 g peak half sine 11 ms pulse Tested in accordance with IEC 60068 2 27 test profile developed in accord...

Страница 31: ...accordance with IEC 60068 2 56 Storage ambient temperature 20 C to 70 C Tested in accordance with IEC 60068 2 1 and IEC 60068 2 2 Storage relative humidity 5 to 95 noncondensing Tested in accordance w...

Страница 32: ...1010 1 UL 61010 1 CSA C22 2 No 61010 1 Caution Overloading the circuits may damage supply wiring Do not exceed the ratings on the equipment nameplate when connecting equipment to the supply circuit No...

Страница 33: ...regulatory compliance information To obtain product certifications and the DoC for this product visit ni com certification search by model number or product line and click the appropriate link in the...

Страница 34: ...ces The NI website is your complete resource for technical support At ni com support you have access to everything from troubleshooting and application development self help resources to email and pho...

Отзывы: