Chapter 2
Installing and Configuring the DAQPad-MIO-16XE-50
©
National Instruments Corporation
2-11
DAQPad-MIO-16XE-50 User Manual
Figure 2-3.
CONVERT* Signal Routing
This figure shows that CONVERT* can be generated from a number of
sources, including the external signals PFI<0..9> and the internal signals
Sample Interval Counter TC and GPCTR0_OUT.
Notice that any of the PFIs can be used as an input by any of the
timing signals and that multiple timing signals can use the same PFI
simultaneously. This flexible routing scheme reduces the need to change
physical connections to the DAQPad-TB-52 for different applications.
You can also individually enable each of the PFI signals to output a specific
internal timing signal. For example, if you need the UPDATE* signal as an
output on the DAQPad-TB-52, software can turn on the output driver for
the PFI5/UPDATE* pin.
PFI<0..9>
CONVERT*
Sample Interval Counter TC
GPCTR0_OUT