4.2 Using Sequence Function
DP060LM/DP120LM/DP180LM
71
Table 4-1 Wattage Limiter Value per Phase (Reference value)
Rated output
(
Unit
:
VA
)
Single-phase
Limiter Value
(
Unit
:
W
)
Single-phase
three-wire
Limiter Value
(
Unit
:
W
)
Three-phase
Limiter Value
(
Unit
:
W
)
Numb
er
of po
wer units
per phase
DP060LM
1
2000 2100 2100 2100
2 4000
4200
3 6000
6300
DP120LM
1
2000 2100 2100 2100
2
4000 4200 4200 4200
3 6000
6300
4 8000
8400
5 10000
10500
6 12000
12600
DP180LM
1
6000 6300 6300 6300
2 12000
12600
3 18000
18900
--------
Notes
------------------------------------------------------------------------------------------------------------
If the wattage limiter operates, suppress the output wattage within the rated output power by
lowering the output voltage setting value.
Active power (unit: W) is restricted by the wattage limiter, however, reactive power (unit: var)
is not restricted. Therefore, the apparent power (unit: VA) may exceed the rated power
depending on the power factor of the load. Set the output voltage so that the apparent power
does not exceed the rated power, regardless of the operation of the wattage limiter.
The value of the wattage limiter cannot be changed. To limit the output power to a value that is
lower than the rating, decrease the number of power units that are energized through the power
unit energization setting, or use the peak current limiter or the RMS current limiter.
-----------------------------------------------------------------------------------------------------------------------------
4.2
Using Sequence Function
4.2.1 Basics
By using Sequence function, an output setting can be changed step-by-step according to the program
(sequence) created beforehand. This section describes the basics for using the Sequence function.
AC/DC Mode and Signal Source
Sequence function keeps the selection of the AC/DC mode and a signal source, independently from
Continuous function/Simulation function. AC/DC mode can be selected from AC/ACDC/DC. A
signal source is fixed as INT.
Содержание DP060LM
Страница 1: ...PROGRAMMABLE AC POWER SOURCE DP060LM DP120LM DP180LM INSTRUCTION MANUAL NF Corporation...
Страница 2: ......
Страница 3: ...PROGRAMMABLE AC POWER SOURCE DP060LM DP120LM DP180LM INSTRUCTION MANUAL DA00059920 004...
Страница 4: ......
Страница 19: ...DP060LM DP120LM DP180LM 1 1 Outline 1 1 Overview 2 1 2 Series Lineup 2 1 3 Features 3...
Страница 24: ......
Страница 215: ...DP060LM DP120LM DP180LM 197 5 Description of Screen and Menu 5 1 Screen Configuration 198 5 2 Menu Composition 202...
Страница 224: ......
Страница 225: ...DP060LM DP120LM DP180LM 207 6 Remote Control 6 1 Communication Interface 208 6 2 Remote Local State Switching 216...
Страница 239: ...DP060LM DP120LM DP180LM 221 8 Peripherals 8 1 Peripherals Line up 222 8 2 Using in Combination with DIP or RIN 223...
Страница 244: ......
Страница 264: ......
Страница 298: ...11 Specifications PROGRAMMABLE AC POWER SOURCE 280 11 35 Outline Dimensional Drawing Figure 11 2 DP060LM Type2L cabinet...
Страница 300: ...11 Specifications PROGRAMMABLE AC POWER SOURCE 282 Figure 11 4 DP180LM Type5L cabinet...
Страница 307: ...http www nfcorp co jp NF Corporation 6 3 20 Tsunashima Higashi Kohoku ku Yokohama 223 8508 JAPAN...