
11.25 Memory Function
DP060LM/DP120LM/DP180LM
271
11.25 Memory Function
You can save basic settings (AC/DC mode, signal source, output range, AC setting, DC setting,
current limiter, setting range limit, etc.) for each output phase configuration in the non-volatile Basic
Setting Memory of No.1 to No.30, and recall them to use when the output is off. The No.1 setting is
restored at power-on. The No.0 setting includes the setting items for the factory default.
The external control, display, and other settings are saved in non-volatile System Setting Memory
when they are changed by the panel operation or remote command.
The Sequence, Simulation, clipped sine wave, and arbitrary wave are saved in their own non-volatile
memories.
Items in the Basic Setting Memory *62
Factory
default
Output range
100 V range
AC/DC mode
AC mode
Signal source
INT
External synchronization signal (LINE or
EXT)
LINE
AC voltage setting
0 V
Frequency 50
Hz
Output waveform
Sine wave
Output on phase and output off phase
0.0°
Phase voltage/Line voltage setting
selection
Phase voltage
Phase angle setting
Single-phase three-wire: 180°
Three-phase four-wire: 120°, 240°
Balanced/Unbalanced Balanced
DC voltage setting
0 V
Current limiter
See
11.14
Setting range limit
See
11.15
External input gain
100 / 200
*62
:
Some items do not exist depending on the AC/DC mode or signal source.
Items in the System Setting Memory
Factory
default
Output function
Continuous
DC offset setting
0 mV
Measurement display mode
Normal View
Measurement unit selection
rms
Power unit energization setting
All enabled (energization)
Output phase configuration
Single-phase two-wire
Remote sensing
Off
AGC Off
General function
See
11.24
(excluding the time unit setting of the Step Time
for the Sequence and Simulation)
Monitor output target
Current (L1 phase)
External interface
USB
External control
Disabled
Содержание DP060LM
Страница 1: ...PROGRAMMABLE AC POWER SOURCE DP060LM DP120LM DP180LM INSTRUCTION MANUAL NF Corporation...
Страница 2: ......
Страница 3: ...PROGRAMMABLE AC POWER SOURCE DP060LM DP120LM DP180LM INSTRUCTION MANUAL DA00059920 004...
Страница 4: ......
Страница 19: ...DP060LM DP120LM DP180LM 1 1 Outline 1 1 Overview 2 1 2 Series Lineup 2 1 3 Features 3...
Страница 24: ......
Страница 215: ...DP060LM DP120LM DP180LM 197 5 Description of Screen and Menu 5 1 Screen Configuration 198 5 2 Menu Composition 202...
Страница 224: ......
Страница 225: ...DP060LM DP120LM DP180LM 207 6 Remote Control 6 1 Communication Interface 208 6 2 Remote Local State Switching 216...
Страница 239: ...DP060LM DP120LM DP180LM 221 8 Peripherals 8 1 Peripherals Line up 222 8 2 Using in Combination with DIP or RIN 223...
Страница 244: ......
Страница 264: ......
Страница 298: ...11 Specifications PROGRAMMABLE AC POWER SOURCE 280 11 35 Outline Dimensional Drawing Figure 11 2 DP060LM Type2L cabinet...
Страница 300: ...11 Specifications PROGRAMMABLE AC POWER SOURCE 282 Figure 11 4 DP180LM Type5L cabinet...
Страница 307: ...http www nfcorp co jp NF Corporation 6 3 20 Tsunashima Higashi Kohoku ku Yokohama 223 8508 JAPAN...