11. Specifications
PROGRAMMABLE AC POWER SOURCE
270
11.23.3 External Signal Input (only EXT and ADD)
This multiplies the input signal by the specified gain and outputs it. For ADD, the internal signal
source is added.
EXT: Output voltage (V) = External signal input (V) x Gain (V/V)
ADD: Output voltage (V) = External signal input (V) x Gain (V/V)
+ Internal signal source setting (V)
External Signal Input cannot be used in the polyphase output.
Specification
Factory
default
Setting Range for gain
100 V range: 0.0 to 227.0 times
100
200 V range: 0.0 to 454.0 times
200
Setting resolution
0.1
Gain accuracy
*61
5 %
Input-output phase
In-phase
Input terminal
BNC connector (rear panel, unbalanced)
Also used as the external synchronization signal input
Input impedance
1 M
Input voltage range
2.2 V (A/D resolution 10 bit)
Nondestructive
maximum input voltage
10 V
Input frequency range
DC to 550 Hz (sine wave)
DC to 100 Hz (other than sine wave)
*61
:
In the DC mode (only in single-phase output) or 45 Hz to 65 Hz, factory default gain, rated output
voltage, and no load.
11.24 General Function
Description
Factory
default
LCD
display
setting
Contrast
0 to 99
Color
Blue tone or white tone
Blue tone
Beep
(key operation, erroneous
operation)
On or Off
Alarms on abnormal situation regardless of the setting
On
Key lock
On or Off
On: Only key lock-off and output-off are available
Off
Output relay control
Enable: The output relay is used to turn the output on/off
Disable: The output relay is not used. High impedance to
turn the output off
Enable
Output setting
at power-on
On or Off
On: Output on after power-on
Off
Trigger output setting
Polarity: positive
or negative
Pulse width: 0.1 ms to 10 ms (resolution 0.1 ms)
Negative
10 ms
Time unit setting for
Sequence and Simulation
ms or s
s
Reset function
Resets the items stored in the System Setting Memory (excluding the
external interface setting and external control setting) and the items that
are to be reset at power-on, to the factory default settings.
Содержание DP060LM
Страница 1: ...PROGRAMMABLE AC POWER SOURCE DP060LM DP120LM DP180LM INSTRUCTION MANUAL NF Corporation...
Страница 2: ......
Страница 3: ...PROGRAMMABLE AC POWER SOURCE DP060LM DP120LM DP180LM INSTRUCTION MANUAL DA00059920 004...
Страница 4: ......
Страница 19: ...DP060LM DP120LM DP180LM 1 1 Outline 1 1 Overview 2 1 2 Series Lineup 2 1 3 Features 3...
Страница 24: ......
Страница 215: ...DP060LM DP120LM DP180LM 197 5 Description of Screen and Menu 5 1 Screen Configuration 198 5 2 Menu Composition 202...
Страница 224: ......
Страница 225: ...DP060LM DP120LM DP180LM 207 6 Remote Control 6 1 Communication Interface 208 6 2 Remote Local State Switching 216...
Страница 239: ...DP060LM DP120LM DP180LM 221 8 Peripherals 8 1 Peripherals Line up 222 8 2 Using in Combination with DIP or RIN 223...
Страница 244: ......
Страница 264: ......
Страница 298: ...11 Specifications PROGRAMMABLE AC POWER SOURCE 280 11 35 Outline Dimensional Drawing Figure 11 2 DP060LM Type2L cabinet...
Страница 300: ...11 Specifications PROGRAMMABLE AC POWER SOURCE 282 Figure 11 4 DP180LM Type5L cabinet...
Страница 307: ...http www nfcorp co jp NF Corporation 6 3 20 Tsunashima Higashi Kohoku ku Yokohama 223 8508 JAPAN...