11. Specifications
PROGRAMMABLE AC POWER SOURCE
260
11.14 Current Limiter
This controls the output voltage for the output current to be within the limiter setting value when the
peak value or RMS exceeds it. The output can be configured to be turned off when the limited state
continues over the specified time.
In the polyphase output, the settings are common to all the phases for the phase current.
When increasing or decreasing the number of working units by the power unit energization setting,
replace the setting range and the factory default setting with the ratio of the number of working units
to the total number of units. (Refer to the example below. Round the digits of less than resolution to
the one with the larger absolute value). Limiter settings are reset to factory default setting when the
number of working power units is changed.
Peak current limiter
Single-phase output
DP060LM DP120LM DP180LM
Positive
current
Setting Range
(Peak value)
+30.0 A to +252.0 A /
+15.0 A to +126.0 A
+60.0 A to +504.0 A /
+30.0 A to +252.0 A
+90.0 A to +567.0 A /
+45.0 A to +283.5 A
Factory default
+252.0 A / +126.0 A
+504.0 A / +252.0 A
+567.0 A / +283.5 A
Negative
current
Setting Range
(Peak value)
252.0 A to
30.0 A /
126.0 A to
15.0 A
504.0 A to
60.0 A /
252.0 A to
30.0 A
567.0 A to
90.0 A /
283.5 A to
45.0 A
Factory default
252.0 A /
126.0 A
504.0 A /
252.0 A
567.0 A /
283.5 A
Resolution
0.1 A
Limiter operation
Select whether to recover automatically (continuous) or turn the output off
when the limited state continues over the specified time (1 s to 10 s,
resolution 1 s).
Factory default setting is output OFF when the limit state continues for
10 s.
Polyphase output
DP060LM DP120LM DP180LM
Positive
current
Setting Range
(Peak value)
+10.0 A to +84.0 A /
+5.0 A to +42.0 A
+20.0 A to +168.0 A /
+10.0 A to +84.0 A
+30.0 A to +189.0 A /
+15.0 A to +94.5 A
Factory default
+84.0 A / +42.0 A
+168.0 A / +84.0 A
+189.0 A / +94.5 A
Negative
current
Setting Range
(Peak value)
84.0 A to
10.0 A /
42.0 A to
5.0 A
168.0 A to
20.0 A /
84.0 A to
10.0 A
189.0 A to
30.0 A /
94.5 A to
15.0 A
Factory default
84.0 A /
.0 A
168.0 A /
84.0 A
189.0 A /
94.5 A
Resolution
0.1 A
Limiter operation
Select whether to recover automatically (continuous) or turn the output off
when the limited state continues over the specified time (1 s to 10 s,
resolution 1 s).
Factory default setting is output OFF when the limit state continues for
10 s.
Содержание DP060LM
Страница 1: ...PROGRAMMABLE AC POWER SOURCE DP060LM DP120LM DP180LM INSTRUCTION MANUAL NF Corporation...
Страница 2: ......
Страница 3: ...PROGRAMMABLE AC POWER SOURCE DP060LM DP120LM DP180LM INSTRUCTION MANUAL DA00059920 004...
Страница 4: ......
Страница 19: ...DP060LM DP120LM DP180LM 1 1 Outline 1 1 Overview 2 1 2 Series Lineup 2 1 3 Features 3...
Страница 24: ......
Страница 215: ...DP060LM DP120LM DP180LM 197 5 Description of Screen and Menu 5 1 Screen Configuration 198 5 2 Menu Composition 202...
Страница 224: ......
Страница 225: ...DP060LM DP120LM DP180LM 207 6 Remote Control 6 1 Communication Interface 208 6 2 Remote Local State Switching 216...
Страница 239: ...DP060LM DP120LM DP180LM 221 8 Peripherals 8 1 Peripherals Line up 222 8 2 Using in Combination with DIP or RIN 223...
Страница 244: ......
Страница 264: ......
Страница 298: ...11 Specifications PROGRAMMABLE AC POWER SOURCE 280 11 35 Outline Dimensional Drawing Figure 11 2 DP060LM Type2L cabinet...
Страница 300: ...11 Specifications PROGRAMMABLE AC POWER SOURCE 282 Figure 11 4 DP180LM Type5L cabinet...
Страница 307: ...http www nfcorp co jp NF Corporation 6 3 20 Tsunashima Higashi Kohoku ku Yokohama 223 8508 JAPAN...