background image

11

Tamper

GPO1
GPO2

GND

B/RX

A/TX
GND

DC+

CP
D1 Clock
D0 Data
GND
G-LED
R-LED
BZ CTRL
K-LED

P1

Blue

P2

Black

Tamper
GPO1
GPO2
GND
B/RX
A/TX
GND
DC+

CP
D1 Clock
D0 Data
GND
G-LED
R-LED
BZ CTRL
K-LED

Tamper output
General purpose I/O
General purpose I/O
Ground
RS485 -
RS485 +
Power supply
Power supply 9-30 VDC

Card Present
Wiegand Data1/Clock/Data, ABA2
Wiegand Data2/Clock/Data, ABA2
Ground
External Green LED control
External Red LED control
External Buzzer control
External Keypad LED control

Description

PIN

Wiegand

x

-
-

x

-
-

x
x

-

x
x
x
x
x
x
x

P1 - Blue

P2 - Black

RS485/

OSDP

Clock/

Data

-
-
-

x
x
x
x
x

-
-
-

x

-
-
-
-

-
-
-

x

-
-

x
x

x
x
x
x
x
x
x
x

Notes:

1. Maximum wiegand cable length is 150 meters and requires a high 
quality shielded cable with minimum AWG18 dimension (=0.8231mm2) 
in an environment free from electrical noise.
2. Wiegand requires dedicated wires for external control of green LED, 
red LED, buzzer and keypad backlight LED.
3. When utilizing the GPI/O’s, each respective GPO1 or GPO2 must 
be connected to each respective pin and also to GND. The general 
purpose input/output will only be activated if so applied in the reader 
configuration. 
4. RS485/OSDP requires twisted pair cable.

Содержание Cidron Combi Reader

Страница 1: ...CIDRON Installation guide Cidron Standard Reader Cidron Combi Reader...

Страница 2: ...tures On Off Auto indicators Light itensity can be adjusted Indicators LED Green Red and Yellow Bi color Backlight in blue color Buzzer Power supply 9 30VDC Current consumption 24VDC idle mode with he...

Страница 3: ...ors Light itensity can be adjusted Indicators LED Green Red and Yellow Bi color Backlight in blue color Buzzer Power supply 9 30VDC Current consumption 24VDC idle mode with heater inactive 60 mA 12VDC...

Страница 4: ...nt cover 2pcs Terminal connector 8 pin 2pcs Installation screws 2pcs Screw plugs 1pc Cable strip 1pc Fixing screw 1pc Quick installation guide Package content Please note that all pictures in this man...

Страница 5: ...5 20 cm In order to facilitate installation a cable length of 20cm is recommended...

Страница 6: ...6 Ensure that the installation plate is fixed in the correct direction i e the arrows pointing upwards...

Страница 7: ...amper switch bulb of the installation plate is flat to be able to push the bulb for correct tamper alarm functionality If it is not flat enough you will find accessories in this manual that will assis...

Страница 8: ...ith the reader make sure to use a flat headed screw with a maximum height of 2 8 mm and a maximum diameter of 7 8 mm on the screw head Make sure not to tighten the screws too hard as doing so will def...

Страница 9: ...should be used a installation box tamperswitch bracket must be installed between the reader and the installation box Utilize screws supplied with the installation box but make sure to use a screw and...

Страница 10: ...10 P1 Blue socket P2 Black socket Make sure to place the terminal connectors with the fastening screws facing towards you...

Страница 11: ...d LED control Description PIN Wiegand x x x x x x x x x x x P1 Blue P2 Black RS485 OSDP Clock Data x x x x x x x x x x x x x x x x x Notes 1 Maximum wiegand cable length is 150 meters and requires a h...

Страница 12: ...able is left in between the reader module and the installation plate Use the enclosed cable strip to fix the cable in the cord grip It is recommended to connect the the wires to the terminal connector...

Страница 13: ...13 When installing the reader to the mounting plate ensure that the reader pin header contact perfectly aligns with the terminal connector block...

Страница 14: ...r the image above and make sure it is fitted correctly In order to do so allign and fit the top snap fastening apply and maintain pressure on the top of the front cover while sliding the front cover o...

Страница 15: ...15 To secure the front cover to the reader use the supplied fixing screw and fix it into the installation plate through the front cover...

Страница 16: ...front cover from the installation plate by inserting the tip of the tool into the slot at the bottom of the front cover and move the tool upwards This will release the front cover without damaging th...

Страница 17: ...Overview programming of reader Resetting the OSDP secure channel see page 21 Changing authentication card see page 20 Setting the reader in programming mode see page 18 Configuring the reader see page...

Страница 18: ...o indicate that it is now in programming mode The Reader is in programming mode for 10 seconds If no other programming card is presented within this time the reader will return to normal mode When a r...

Страница 19: ...d to the reader as shown Keep the card within reading distance until the reader beeps and blinks in green The reader is now programmed and ready for use according to the configuration settings on the...

Страница 20: ...rd within reading distance un til the reader beeps and blinks in green The reader is now reprogrammed to only be set in programming mode by the new Authentication Card The old Authentication Card is n...

Страница 21: ...lation mode Card to the reader as shown Keep the card within reading distance until the reader beeps and blinks in green The reader has now reset the secure channel encryption keys to installation mod...

Страница 22: ...ket by unlocking and opening the lid Then place the SAM into the socket lock it into place by closing the lid and sliding it into locked position MIFARE SAM AV2 SIM Card part no SK2010 Software ISLOG...

Страница 23: ...23 CIDRON Accessories Cidron Standard Reader Cidron Combi Reader...

Страница 24: ...eaders in environments where the installation surface is uneven or and external wiring at the same side as the reader Can also be used when mounting readers over installation boxes Distance plate stan...

Страница 25: ...a where additional cover is needed to hide old installation holes or on uneven surfaces Can also be used with external wiring on the same side as the reader Distance plate large Matte black part no SC...

Страница 26: ...26 Used to increase accessibility as well as visibility of the keypad Distance plate angled 10 Matte black art nr SC9193 S Matte white art nr SC9193 V...

Страница 27: ...ed height is 900mm center of reader above the ground floor Note The reader can also be installed turned around 180 degrees for use on speed gates or tabletop readers for instance Distance plate angled...

Страница 28: ...the reader and helps it withstand violence by absorbing and redirecting external forces away from the reader Can be retro fitted to already installed readers Vandalization protection Screws and screw...

Страница 29: ...A recommended combination when external wiring is needed together with the vandalization protection Can also be used for covering up old installation holes Distance plate large Vandalization protecti...

Страница 30: ...ender format When installing readers in intense sunny conditions the white version SC9901 V is recommended to use as a shading accessory to provide an environ ment for the reader without direct intens...

Страница 31: ...aning instructions Use compressed air in between the buttons to remove dust and dirt and after that Isopropyl alcohol can be used with a piece of fabric to rub in between the buttons and the reader ex...

Страница 32: ...Cidron readerfamily are intended for Sale to professional security companies and installation by experienced security professionals Nexus Group can not provide assurance that any entity or person buyi...

Отзывы: