nextys SBP200L Скачать руководство пользователя страница 1

 

 
 

SBP200L

 user manual rev6 

Page 1/12 

 

 
 
 
 
 

SBP200L 

 

200W DIN Rail Programmable Output 

Voltage Power Supply  

 

User Manual 

 
 
 
 

 

 
 
 

POWERMASTER

 

 

 

 

 

 

 

 

 

 
 

SBL200L_040-01-700-022-EH-1117

Содержание SBP200L

Страница 1: ...SBP200L user manual rev6 Page 1 12 SBP200L 200W DIN Rail Programmable Output Voltage Power Supply User Manual POWERMASTER SBL200L_040 01 700 022 EH 1117...

Страница 2: ...h the failure of the NEXTYS product could create a situation where personal injury or death may occur Should Buyer purchase or use NEXTYS products for any such unintended or unauthorized application B...

Страница 3: ...al description 4 2 1 Operating modes 5 2 1 1 Operating mode 1 enable disable 5 2 1 2 Operating mode 2 external toggle 6 2 1 3 Operating mode 3 enable disable with timer 6 2 2 Interfaces 7 2 2 1 HMI Hu...

Страница 4: ...as battery charger lead acid nickel lithium Can be used for LED lighting Can be paralleled for power or redundancy with external ORing module Up to 50 C operating temperature with no derating Suitable...

Страница 5: ...or details of this parameter Output voltage 2 U2 See operating mode description for details of this parameter Output current 2 I2 See operating mode description for details of this parameter Delay Del...

Страница 6: ...ith timer In operating mode 3 the device output is activated by the enable input The output toggles to the second set of voltage and current after a defined time Output deactivates when the ENABLE inp...

Страница 7: ...ge Polarity 5s No store 2s Set Set Store Set 5s Output Voltage Modbus address 5s 2s Set Set Store Set 5s Output Voltage Baudrate 5s No store 2s Set Set Store Set 5s Output Voltage Modbus stop bits 5s...

Страница 8: ...ster 3 4 6 16 1 1 2 1 active low polarity 2 active high polarity Modbus settings loaded on next startup Address 0x1100 4352 Hold register 3 4 6 16 1 1 247 Baudrate 0x1100 4353 Hold register 3 4 6 16 1...

Страница 9: ...par un d faut interne Ne pas essayer de r parer ou modifier le produit si des d faillances se produisent pendant le fonctionnement ou les dysfonctionnements le retourner au fabricant pour inspection...

Страница 10: ...ard until it hits the stop 4 Press against the bottom for locking 1 2 3 4 Dismounting 1 Pull down the slide clamp lever 2 Tilt the unit upward 3 Unhook the unit from the rail 1 2 3 Recommended connect...

Страница 11: ...y recommended to provide external surge arresters SPD according to local regulations Environment Operating temperature Derating 40 C 70 C 5 95 r H non condensing Overtemperature protection Over 60Vdc...

Страница 12: ...to the latest Reference standards if not expressly indicated through the official documents or files they have been tested through our internal pre compliance testing Consult directly on www nextys co...

Страница 13: ...999 Kurt Stritzelberger Pewatron AG Edisonstra e 16 D 85716 Unterschlei heim Phone 49 89 260 52 80 Mobile 49 171 803 41 35 kurt stritzelberger pewatron com Postcode 32000 37999 Postcode 40000 79999 Ge...

Отзывы: