1 | P a g e
nextiva.com/support
AudioCodes
Installation Guide
Страница 1: ...1 P a g e nextiva com support AudioCodes Installation Guide ...
Страница 2: ...d Contents Installation 2 Box Contents 2 Mounting the Mediant 500 on a server rack 2 Installing the Mediant Series SBC 3 Status Lights 5 Logging in to the Web Interface from a connected computer 5 Provisioning the Device 6 Factory Reset 9 ...
Страница 3: ...supplied 19 in Rack Mounting Kit which consists of two mounting brackets one left and one right mounting bracket and screws 1 Attach the two mounting brackets supplied to each side of the device s chassis using the supplied screws Figure 1 1 Figure 1 1 Attaching the Mounting Brackets 1 Left mounting rracket 2 Attached screws 3 Right Mounting Bracket 2 Place the device on a pre installed shelf in t...
Страница 4: ...anel of the Mediant SBC NOTE You will need at least one more Ethernet cable than the number of devices you will plug into the Mediant SBC Follow the steps below to install the Mediant Series SBC into your network hierarchy Figure 1 2 Figure 1 2 Standard Network Diagram 1 Connect one end of an Ethernet cable to the LAN 1 port on the front of the Mediant 500 Connect the other end of the cable to you...
Страница 5: ...g a PBX with a PRI Connection to the Mediant 500 one of the Gigabit Ethernet ports will be configured as a PRI Connection Figure 1 3 Figure 1 3 PBX with a PRI Connection Network Diagram 3 Connect one end of the AC power cable to the back of the Mediant 500 and the other end to a three pronged power source ...
Страница 6: ...ailability redundant system Solid Red Boot failure LAN Ports Solid Green Ethernet link is active Flashing Green Data is being transmitted to or received from the attached device No Light No recognizable link the device may not have power or the Ethernet cable may not be providing any data Logging In to the Web Interface from a Connected Computer 1 Ensure the computer you are using is connected int...
Страница 7: ... the CLI script resides Figure 2 1 You can download the skinny config at the following URL Insert URL as it becomes known Figure 2 1 The Skinny Config File NOTE Nextiva Support cannot remote in to your computer to perform the steps below because your computer must be connected to the Mediant 500 which will not have an Internet connection 1 Connect an Ethernet cable from your computer to one of the...
Страница 8: ... 9 Find the skinny config file on your computer and click Open Figure 2 3 Figure 2 3 The Open Window 10 Click Load CLI Script File to the right of Choose File and then click OK when the pop up message appears saying the device will reset After a few seconds the Mediant 500 restarts Proceed to the next step quickly to avoid having to reboot the Mediant 500 again ...
Страница 9: ... a computer to the same network switch the Mediant 500 is connected to 2 Navigate to the static IP Address of the Mediant 500 in a web browser on the computer If you do not know this IP Address please coordinate with your Network Administrator to verify the IP Address of the Mediant 500 using the ARP table present in your network routing device 3 Log in with Admin as the Username and v01p4f n as t...
Страница 10: ... 1 Open a web browser on the computer and navigate to the static IP address of the Mediant 500 The AudioCodes login page appears 2 Log in with Admin as the Username and v01p4f n as the Password 3 Click Maintenance in the upper left corner of the screen 4 Click Software Update on the far left side of the screen 5 Click Configuration File on the far left side of the screen 6 Click Restore Defaults i...
Страница 11: ...Wait until all the red lights on the Mediant 500 turn off and then connect an Ethernet cable from the LAN1 port on the front of the Mediant 500 to the computer NOTE After connecting the Ethernet cable wait until the network status icon in the system tray of the computer no longer shows any errors before proceeding Figure 3 2 Figure 3 2 The Network Status Icon 3 Navigate to 192 168 0 2 in a web bro...