1|Product Review 

The NextCentury TR-201 (Transceiver) is an easy to use, full-feature 
device  developed  to  remotely  collect  meter  reads.  It  can  be 
connected  to  either  a  passive  or  active  pulse-output  meter.  A 
Transceiver  can  send/receive  recorded  data  to/from  a  GW-301 
Gateway, and comes with a replaceable lithium battery. The TR-201 

Transceiver has the longest range in its class with easy to understand 
LED  light  indicators.  Indicators  allow  for  immediate  verification  of 
transmission delivery during setup/maintenance. 

 

1.1

 

- TR-201 Hardware 

 

Figure 1 

TR-201 Hardware

 

            A 

Battery

 

                              B 

Tamper Button         

            

Test Button

                             D 

Degson Connector (Blue)      

            

E

 Signal Status LED

                    F 

Mounting Plate

 

            G 

Plastic Release Tab                 

 

 

2|Specifications 

2.1 - Dimensions:  

 

74.7mm x 40.3mm x 29.1mm 

 

2.9in x 1.6in x 1.1in

 

2.2 - Operation enviorment: 

 

-28C to 60C  

 

-20F to 140F 

 

Up to 90% relative humidity (non-condensing)

 

 

Must be installed in an indoor environment

 

2.3 Certifications: 

 

FCC: 2A8BI-TR-20-214 

 

IC: 20949-TR20214 

2.4 Typical battery life: 

 

6 years average 

Note:

  Typical  battery  life  assumes  constant  operating  temperatures  are 

between 70°F and 90°F. Battery life may be reduced with operation outside of 
this range. 

 

 

 

 

3|Installations and Setup 

3.1 - Connect Transceiver to Meter 

Connect a Transceiver to a meter as follows:  
1.

 

Open the Transceiver plastics by pressing in on the plastic 

release tab (Figure 1-G) while lifting away the cover.  

2.

 

Remove  the  Degson  Connector  (Figure  1-D)  from  the 
Transceiver board by pulling up on it. 

3.

 

Insert the stripped colored wire ends from the meter into 

the  two-terminal  Degson  Connector.    If  a  Degson 
Connector  is  already  present,  ensure  the  wires  are 
seated/fastened firmly in place. 

4.

 

Use a small Phillips screwdriver to tighten the screws that 
secure wires to the Degson Connector. 

5.

 

Place  the  Degson  Connector  back  onto  the  Transceiver 
board as shown in Figure 2.  

Note:

 If connected to an active pulse meter that has a polarity pulse output, 

the positive (+) wire should be placed in the Degson Connector, so when the 

Degson  Connector  is  placed  on  the  Transceiver  board,  the  positive  wire  is 
aligned with the (+) indicator on the board. 
 
 

 

Figure 2 

Connect Transciever to Meter 

           A

 Wire Slot          

B

 Degson Connector (Blue) 

 

3.2 - Mount the Transceiver 

Each Trasnceiver comes with a mounting plate and can be installed in 
one of three different ways

.  

1.

 

NextCentury’s  M201C  and  M201CH  meters  have  a 
mounting plate that can be attached to them.  Simply slide 
the Transceiver onto the mounting plate. When using this 

method, the Transceiver mounting plate (Figure 1-F) can be 
discarded. 

2.

 

Remove  the  3M  double-sided  protective  cover  and  place 
the Transceiver mounting plate (Figure 1-F) on a clean wall.  

3.

 

Use  the  mounting  screws  and  anchors  to  secure  the 
Transceiver mounting plate (Figure 1-F) to the wall. 

Note: 

Ensure the wiring enters through the wire slot (Figure 2-A), allowing the 

top Transceiver plastic cover to be closed completely. 

 

 
 
 
 
 
 
 

 
 