Level 2 — Reduce disk speed after 10 minutes
Level 3 — Stop disks spinning after 15 minutes
Level 4 — Power off disks after 20 minutes
2. Click
Save Level 1-4 Settings
.
A message is displayed, informing you that the settings have been changed. Click the
Back
button to return to
the
Configure AutoMAID Settings
page.
Note
NL-SAS drives are not compatible with AutoMAID Level 4. Pool spare or unassigned NL-SAS drives set
to use AutoMAID Level 4 will remain at AutoMAID Level 3.
RAID Array Specific Settings
In the
RAID Array Specific Settings
section, the default setting is
Default
. Click the
Customize
link to set
AutoMAID settings for an individual array:
Figure 3-135:
Configure AutoMAID Settings
page for a specific RAID array
Choose the settings in this section exactly as you would in the
Default RAID Array AutoMAID Settings
section, then click
Save Current Settings
. A message is displayed, informing you that the new power
settings have been saved.
If you wish to return an array to default settings, click
Reset Default Settings
. A message is displayed,
informing you that the new power settings have been saved.
AutoMAID 5 Settings
Note
AutoMAID 5 settings only apply to the BEAST BT60X, Nexsan E60X™/E60XV™ and Nexsan
E48X™/E48XV™ expansion units. The Nexsan E32XV™ and Nexsan E18X™/E18XV™ units do not have
AutoMAID 5 capability.
The
AutoMAID 5 Settings
section controls how soon the expansion units power completely down after all
disks in the expansion unit are at AutoMAID level 4.
Chapter 3: The Graphical User Interface — Power Settings
Nexsan High-Density Storage
User Guide