Lost Data/Bad Blocks
Clicking
Configure RAID > Lost Data
takes you to the
Lost Data/Bad Blocks
page. In RAID 0 arrays, data
is lost if any of the component disks fail or develop errors. In RAID 1, RAID 4, and RAID 5 arrays, data is only
lost if two or more component disks fail or develop errors simultaneously. In RAID 6 arrays, data is only lost if
three or more component disks fail or develop errors simultaneously. See
page 252 for more information.
Normally, the
Lost Data/Bad Blocks
page looks like this:
Figure 3-81:
Lost Data/Bad Blocks
page with no error message
When there is a lost data warning, the
Lost Data/Bad Blocks
page looks like this:
Figure 3-82:
Lost Data/Bad Blocks
page with bad data blocks message
Click the
Acknowledge Lost Data Warning
button to acknowledge the warning. A message is displayed,
confirming the acknowledgment. Click the
Back
button to return to the
Lost Data/Bad Blocks
page.
Notes:
After acknowledging lost data, it is STRONGLY RECOMMENDED that you run an array verification
immediately. See
on page 133 for instructions.
Lost data warnings also appear on the
Home
page and can be acknowledged from there (see
Chapter 3: The Graphical User Interface — Configure RAID
Nexsan High-Density Storage
User Guide
136