background image

NEXCOM International Co., Ltd.

NEXCOM International Co., Ltd.

Published August 2022

www.nexcom.com

Network

 

and

 

Communication

 

Solutions

Network Security Appliance 
NSA 7150/7150A

User Manual

Содержание NSA7150

Страница 1: ...NEXCOM International Co Ltd NEXCOM International Co Ltd Published August 2022 www nexcom com Network and Communication Solutions Network Security Appliance NSA 7150 7150A User Manual ...

Страница 2: ...ey Features 1 Hardware Specifications 2 Knowing Your NSA 7150 3 Front Panel 3 Rear Panel 4 Chapter 2 Jumpers and Connectors Before You Begin 5 Precautions 5 Jumper Settings 6 Locations of the Jumpers and Connectors 7 Jumper 8 RTC Clear 8 XDP Debug Header 8 BMC Remote SPD Debug Header 9 PCH Strap Debug Use 9 PCH Strap Debug Use 10 CPLD JTAG Select 10 CPLD JTAG Select 11 PFR Recovery 11 AT ATX Heade...

Страница 3: ...OCP Slot Connector 33 M 2 Connector M Key 35 Block Diagram 36 Chapter 3 System Setup Removing the Chassis Cover 37 Installing a LAN Module 38 Installing a CPU 40 Removing the Front Cover 40 Removing the Rear Cover 41 Removing the Middle Cover 42 Installing the CPU 43 Installing Memory Modules 46 CPU and Memory Layout 47 DDR4 Memory Population Table 48 DDR4 and Intel Optane Persistent Memory Popula...

Страница 4: ...marks of NEXCOM International Co Ltd All other product names mentioned herein are registered trademarks of their respective owners Regulatory Compliance Statements This section provides the FCC compliance statement for Class A devices and describes how to keep the system CE compliant Declaration of Conformity FCC This equipment has been tested and verified to comply with the limits for a Class A d...

Страница 5: ...and Polybrominated diphenyl Ethers PBDE 0 1 or 1 000ppm In order to meet the RoHS compliant directives NEXCOM has established an engineering and manufacturing task force in to implement the introduction of green products The task force will ensure that we follow the standard NEXCOM development procedure and that all the new RoHS components and new manufacturing processes maintain the highest indus...

Страница 6: ...esponsible for the safe packaging of defective products making sure it is durable enough to be resistant against further damage and deterioration during transportation In case of damages occurred during transportation the repair is treated as Out of Warranty Any products returned by NEXCOM to other locations besides the customers site will bear an extra charge and will be billed to the customer Re...

Страница 7: ...s and power supply are inconsistent with these instructions or the instructions for accessory modules contact the supplier to find out how you can ensure that your computer meets safety and regulatory requirements Cautions Electrostatic discharge ESD can damage system components Do the described procedures only at an ESD workstation If no such station is available you can provide some ESD protecti...

Страница 8: ...mage the soft metal or plastic parts of the connectors Safety Information Before installing and using the device note the following precautions Read all instructions carefully Do not place the unit on an unstable surface cart or stand Follow all warnings and cautions in this manual When replacing parts ensure that your service technician uses parts specified by the manufacturer Avoid using the sys...

Страница 9: ... the voltage and current rating marked on the product 10 All cautions and warnings on the equipment should be noted 11 If the equipment is not used for a long time disconnect it from the power source to avoid damage by transient overvoltage 12 Never pour any liquid into an opening This may cause fire or electrical shock 13 Never open the equipment For safety reasons the equipment should be opened ...

Страница 10: ...mation of the installed software operating system version application software etc A complete description of the problem The exact wordings of the error messages Warning 1 Handling the unit carry the unit with both hands and handle it with care 2 Maintenance to keep the unit clean use only approved cleaning products or clean with a dry cloth Conventions Used in this Manual Warning Information abou...

Страница 11: ...ei City 23586 Taiwan R O C Tel 886 2 8226 7786 Fax 886 2 8226 7926 Email jennyshern nexcobot com www nexcobot com GreenBase Technology Corp 13F No 922 Zhongzheng Rd Zhonghe District New Taipei City 23586 Taiwan R O C Tel 886 2 8226 7786 Fax 886 2 8226 7900 Email vivianlin nexcom com tw www nexcom com tw DivioTec Inc 19F 1A No 97 Sec 4 ChongXin Rd Sanchong District New Taipei City 24161 Taiwan R O ...

Страница 12: ...ng 15 Yard 3 Gaolizhang Road Haidian District Beijing 100094 China Tel 86 10 5704 2680 Fax 86 10 5704 2681 Email marketing nexsec cn www nexsec cn NEXCOM Shanghai Room 406 407 Building C No 154 Lane 953 Jianchuan Road Minhang District Shanghai 201108 China Tel 86 21 5278 5868 Fax 86 21 3251 6358 Email sales nexcom cn www nexcom cn NEXCOM Surveillance Technology Corp Floor 8 Building B3 Xiufeng Ind...

Страница 13: ...l the items listed in the following table Item Part Number Name Qty 1 19S00715000X0 NSA 7150 1 2 50311F0110X00 Flat Head Screw 8 3 5044440031X00 Rubber Foot Set 4 4 6023309081X00 DB9 to RJ45 Console Cable 1 5 5050300975X00 NSA 7150 Series Heat Sink 2 6 5061600239H00 CPU Socket Carrier 2 7 50311F0654X00 I Head Screw 1 8 50311F0162X00 Round Head Screw 1 9 5040150001X00 Hook Handle For retrieving LAN...

Страница 14: ...formation The following information below provides ordering information for NSA 7150 7150A Barebone NSA 7150 P N 10S00715000X0 2U dual Intel 3rd Xeon Scalable Processor w o QAT LCM 8 x LAN modules and RunBMC NSA 7150A P N 10S00715001X0 2U dual Intel 3rd Xeon Scalable Processor w QAT LCM 8 x LAN modules and RunBMC ...

Страница 15: ... 4 SFP None None 10G 3 4 7 8 NX 140F OS 2BS20140F02X0 XL710 BM1 PCIe x8 4 SFP None None 10G 1 2 5 6 NX 140C2F2W 2BS20140F07X0 EZX710TM4 PCIe x8 2 Copper 2 SFP None None 10G 3 4 7 8 NX 142FX1W 2BS20142F05X0 XL710 BM1 PCIe x8 4 SFP 2 bypass None 10G 3 4 7 8 NX 142FX1W LR 2BS20142F06X0 XL710 BM1 PCIe x8 4 SFP 2 bypass None 10G 3 4 7 8 NX 142FX1 OS 2BS20142F01X0 XL710 BM1 PCIe x8 4 SFP 2 bypass None 1...

Страница 16: ...Copyright 2021 NEXCOM International Co Ltd All Rights Reserved xvi NSA 7150 7150A User Manual Preface 1 2 5 6 3 4 7 8 ...

Страница 17: ...neration dual Intel Xeon scalable processor 20 x DDR4 3200 ECC RDIMM LRDIMM Support Intel Optane Persistent Memory 2 x 2 5 swappable SSD HDDs 2 x Management ports 8 x PCIe 4 LAN modules Overview Support Intel QAT NSA7150A 1 x PCIe 4 x16 low profile riser card 1 x PCIe 4 x16 FHFL card Optional Support OCP NIC 3 0 Support IPMI 2 0 RunBMC 1300W 1 1 CRPS redundant power supply ...

Страница 18: ...ey socket I O Interface External Button Power Reset NMI LED PWR STBY HDD ERR 2 x 2 5 swappable SSD HDD bays 2 x USB 3 0 ports 1 x RJ45 type console 8 x LAN Module Slots 1 x PCIe 4 x16 Low Profile Card 8 x OCP NIC 3 0 Slots 1 x PCIe 4 x16 Low Profile Card Optional 4 x LAN Module Slots 1 x PCIe 4 x16 FHFL Card Optional 2 x Management ports 1 x VGA port for BMC SKU 3 x Swappable smart fans 2 x Power ...

Страница 19: ...HDD SSD swappable bays for installing HDD SSDs LED Indicators Indicates the power status error status and storage drive activity of the system Reset Button Press to restart the system RJ45 Type Management LAN Port RJ45 type LAN ports used for managing the system SFP Type Management LAN Port SFP port used for managing the system USB Ports Used to connect USB 3 0 2 0 1 1 devices RJ45 Type Console Se...

Страница 20: ...er Switch Press to power on or power off the system VGA Used to connect an analog VGA monitor AC Power Sockets Dual redundant power supply sockets plug an AC power cord here before turning on the system Ground Screw The round head screw included in the accessory pack P N 50311F0162X00 can be installed here as the ground screw Ensure that the ground screw is installed first before use ...

Страница 21: ...nd yourself before touching any internal components by touching a metal object Static electricity can damage many of the electronic components Humid environments tend to have less static electricity than dry environments A grounding strap is warranted whenever danger of static electricity exists Precautions Computer components and electronic circuit boards can be damaged by discharges of static el...

Страница 22: ...the jumpers ensure that the jumper caps are placed on the correct pins When the jumper cap is placed on both pins the jumper is short If you remove the jumper cap or place the jumper cap on just one pin the jumper is open Refer to the illustrations below for examples of what the 2 pin and 3 pin jumpers look like when they are short on and open off Two Pin Jumpers Open Left and Short Right Three Pi...

Страница 23: ... 77 D14 78 221 222 77 78 221 222 77 78 221 222 77 78 221 222 77 78 221 222 77 78 221 222 77 78 221 222 77 78 221 222 77 78 221 222 77 78 144 288 144 288 144 288 144 288 144 288 144 288 144 288 144 288 144 288 144 145 221 288 D9 78 77 221 77 221 77 221 77 221 77 144 288 144 288 144 288 144 288 144 222 78 222 78 222 78 222 78 222 1 145 1 145 1 145 1 145 1 D10 D11 D12 D13 A40 A1 B40 B1 A40 A1 B40 B1 ...

Страница 24: ...ormal 2 3 On Clear CMOS 1 2 On default Pin Definition 1 NC 2 RST_RTCRST_N 3 GND XDP Debug Header Connector type 2x3 6 pin header Connector location JP5 Pin Function 1 3 On Force Bypass of CPU1 3 5 On Normal Operation 2 4 On Force Bypass of CPU2 4 6 On Normal Operation 3 5 4 6 On default Pin Definition Pin Definition 1 NC 2 NC 3 FM_CPU1_SKTOCC_N 4 FM_CPU2_SKTOCC_N 5 FM_CPU1_SKTOCC_ LVT3_N 6 FM_CPU2...

Страница 25: ...header Connector location JP4 Pin Function 1 2 On SPD Remote Debug Enabled Pin Definition 1 P3V3_AUX 2 RST_SMB_SWITCH_N 1 2 1 11 2 12 Pin Function 1 3 On ME Force Update 1 3 Off Normal Default 5 7 On Password Clear 5 7 Off Normal Default 2 4 On LT Key Downgrade Enable 2 4 Off LT Key Downgrade Disable Default 6 8 On Flash Security Override Enable 6 8 Off Flash Security Override Disable Default 10 1...

Страница 26: ...2 Pin Definition Pin Definition 1 FM_ME_RCVR_N 2 FM_LT_KEY_ DOWNGRADE_N 3 GND 4 GND 5 FM_PASSWORD_ CLEAR_N 6 P3V3_AUX 7 GND 8 AUD_AZA_SDO 9 FM_PCH_BMC_ THRMTRIP_EXI_STRAP_N 10 P3V3_AUX 11 GND 12 FM_PCH_BIOS_RCVR_ SPKR CPLD JTAG Select Connector type 1x2 2 pin header Connector location JP17 Pin Function 1 2 On JTAG Header to CPLD JTAG Pin 1 2 Off BMC to CPLD JTAG Pin Default Pin Definition 1 JTAG_S...

Страница 27: ...G 1 2 Off Normal For remote update CPLD 1 2 PFR Recovery Connector type 2x3 6 pin header Connector location JP20 Pin Function 1 2 On Force Pfr Recovery 1 2 Off Normal Operation Default 3 4 On Force Pfr Cpld Update 3 4 Off Normal Operation Default 5 6 On PFR CPLD in Debug Mode 5 6 Off Normal Operation Default Pin Definition Pin Definition 1 FM_PFR_FORCE_ RECOVERY_N 2 GND 3 FM_PFR_PROV_ UPDATE_N 4 G...

Страница 28: ...rs and Connectors AT ATX Header CPLD JTAG PROG Enable Header Connector type 2x3 6 pin header Connector location JP18 Pin Function 1 3 On ATX Default 3 5 On AT 2 4 On Enable PROG Default 4 6 On Disable PROG Pin Definition Pin Definition 1 P3V3_CPLD 2 P3V3_CPLD 3 AT_ATX_SEL 4 JTAG_PLD_JTAGEN 5 GND 6 GND 1 5 2 6 ...

Страница 29: ...er Connector location CON1 Internal Power Connector CN1 to CON1 Connector type 2x4 8 pin header Connector location CN1 9 1 16 8 Pin Definition Pin Definition 1 GND 2 GND 3 GND 4 GND 5 P12V_AUX 6 P12V_AUX 7 P12V 8 P12V 9 P12V_AUX 10 P12V_AUX 11 P12V_AUX 12 P12V_AUX 13 P12V_AUX 14 P12V_AUX 15 P12V 16 P12V Pin Definition Pin Definition 1 GND 2 GND 3 GND 4 GND 5 P12V_AUX 6 P12V_AUX 7 P12V_AUX 8 P12V_A...

Страница 30: ...onnector CN2 to CN12 Connector type 2x4 8 pin header Connector location CN2 and CN12 Internal Power Connector Connector type 2x4 8 pin header Connector location CN3 Pin Definition Pin Definition 1 GND 2 GND 3 GND 4 GND 5 P12V 6 P12V 7 P12V 8 P12V Pin Definition Pin Definition 1 GND 2 GND 3 GND 4 GND 5 P12V 6 P12V 7 P12V 8 P12V 1 1 4 4 8 8 5 5 ...

Страница 31: ...or location CN6 Pin Definition Pin Definition 1 P12V_AUX 2 P12V_AUX 3 P12V 4 P12V 5 P12V_AUX 6 P12V_AUX 7 P12V 8 P12V Pin Definition Pin Definition A1 9 GND B1 9 GND A10 18 P12V B10 18 P12V A19 SMB_PFR_PMB1_STBY_ LVC3_CRPS_SDA B19 GND A20 SMB_PFR_PMB1_STBY_ LVC3_CRPS_SCL B20 FM_PS_EN_PSU_N A21 GND B21 P12V_STBY_PSU A22 IRQ_SML1_PMBUS_ BMC_ALERT_N B22 RETURN_SENSE A23 PWRGD_PS_PWROK B23 CRPS_PRESEN...

Страница 32: ... 7150A User Manual Chapter 2 Jumpers and Connectors Header to LED Connector type 1x2 2 pin header Connector location JP12 Header to BTN Switch Connector type 1x2 2 pin header Connector location JP13 Pin Definition 1 P3V3_CPLD 2 ID_LED_N Pin Definition 1 PWRBTN_N 2 GND 1 2 1 2 ...

Страница 33: ... A13 GND B13 GND A14 PE_SLOT_RX_DP2 B14 PE_SLOT_TX_C_DP2 A15 PE_SLOT_RX_DN2 B15 PE_SLOT_TX_C_DN2 A16 GND B16 GND A17 PE_SLOT_RX_DP3 B17 PE_SLOT_TX_C_DP3 A18 PE_SLOT_RX_DN3 B18 PE_SLOT_TX_C_DN3 A19 GND B19 GND A20 NC B20 NC Pin Definition Pin Definition A21 NC B21 NC A22 GND B22 GND A23 PE_SLOT_RX_DP4 B23 PE_SLOT_TX_C_DP4 A24 PE_SLOT_RX_DN4 B24 PE_SLOT_TX_C_DN4 A25 GND B25 GND A26 PE_SLOT_RX_DP5 B2...

Страница 34: ...14 PE_SLOT_TX_C_DP2 A15 PE_SLOT_RX_DN2 B15 PE_SLOT_TX_C_DN2 A16 GND B16 GND A17 PE_SLOT_RX_DP3 B17 PE_SLOT_TX_C_DP3 A18 PE_SLOT_RX_DN3 B18 PE_SLOT_TX_C_DN3 A19 GND B19 GND A20 NC B20 NC Pin Definition Pin Definition A21 NC B21 NC A22 GND B22 GND A23 PE_SLOT_RX_DP4 B23 PE_SLOT_TX_C_DP4 A24 PE_SLOT_RX_DN4 B24 PE_SLOT_TX_C_DN4 A25 GND B25 GND A26 PE_SLOT_RX_DP5 B26 PE_SLOT_TX_C_DP5 A27 PE_SLOT_RX_DN5...

Страница 35: ...ers and Connectors Fan Connector Connector type 1x6 6 pin header Connector location J4 J5 and J6 Fan Connector Connector type 1x4 4 pin header Connector location CN23 and CN28 Pin Definition Pin Definition 1 GND 2 GND 3 P12V 4 P12V 5 TACH 6 PWM Pin Definition Pin Definition 1 GND 2 P12V 3 TACH 4 PWM 1 1 6 4 ...

Страница 36: ...ser Manual Chapter 2 Jumpers and Connectors 1 3 Power Team Debug Header Connector type 1x3 3 pin header Connector location JP14 CPU1 and JP23 CPU2 Pin Definition 1 SDA 2 SCL 3 GND SYS RTC Header Connector type 1x2 2 pin header Connector location J1 Pin Definition 1 GND 2 3V3_BAT 1 2 ...

Страница 37: ...umpers and Connectors SATA Power Connector Connector type 1x4 4 pin header Connector location J2 IPMB Debug Header Use Connector type 1x4 4 pin header Connector location CN5 Pin Definition Pin Definition 1 P5V 2 GND 3 GND 4 P12V Pin Definition Pin Definition 1 IPMB_DATA 2 GND 3 IPMB_CLK 4 P5V_AUX 1 1 4 4 ...

Страница 38: ...s SATA Connectors Connector type Standard Serial ATA 7P 1 27mm SATA M 180 Connector location CN8 CN9 and CN10 Pin Definition Pin Definition 1 GND 2 TXP 3 TXN 4 GND 5 RXN 6 RXP 7 GND 1 7 BMC Debug Header Connector type 1x4 4 pin header Connector location JP26 Pin Definition Pin Definition 1 3 3V 2 UART_RX 3 UART_TX 4 GND 1 4 ...

Страница 39: ...in Definition Pin Definition 1 P3V3_AUX 2 SPI_PCH_TPM_CS_R_N 3 NC 4 IRQ_TPM_SPI_N 5 RST_PLTRST_TPM_R_N 6 NC 7 NC 8 GND 9 NC 10 SPI_TPM_CLK_R 11 SPI_PCH_MUXED_R_IO1 12 SPI_PCH_MUXED_R_IO0 13 NC 14 NC 1 6 CPLD JTAG for Programming CPLD Code Connector type 1x6 6 pin header Connector location JP25 Pin Definition Pin Definition 1 P3V3_CPLD 2 GND 3 JTAG_TCK_CPLD 4 JTAG_TDO_CPLD 5 JTAG_TDI_CPLD 6 JTAG_TM...

Страница 40: ...3 TRC_2CH0_CLK 14 GND 15 GND 16 GND 17 GND 18 NC 19 TRC_2CH0_D0 20 NC 21 TRC_2CH0_D1 22 NC 23 TRC_2CH0_D2 24 NC 25 TRC_2CH0_D3 26 NC 27 TRC_2CH0_D4 28 NC 29 TRC_2CH0_D5 30 NC Pin Definition Pin Definition 31 TRC_2CH0_D6 32 NC 33 TRC_2CH0_D7 34 NC 35 TRC_2CH1_D0 36 NC 37 TRC_2CH1_D1 38 NC 39 TRC_2CH1_D2 40 NC 41 TRC_2CH1_D3 42 DBP_VISA_RSMRST_N 43 TRC_2CH1_D4 44 NC 45 TRC_2CH1_D5 46 NC 47 TRC_2CH1_...

Страница 41: ...UG_CONSENT_N 16 GND 17 FM_DBP_PRESENT_R_N 18 GND 19 MCI_CPU1_PTI0 20 GND 21 MCI_CPU1_PTI1 22 GND 23 MCI_CPU1_PTI2 24 GND 25 MCI_CPU1_PTI3 26 GND Pin Definition Pin Definition 27 MCI_CPU1_PTI4 28 GND 29 MCI_CPU1_PTI5 30 GND 31 MCI_CPU1_PTI6 32 GND 33 MCI_CPU1_PTI7 34 NC 35 MCI_CPU1_PTI8 36 DBP_SYSPWROK 37 MCI_CPU1_PTI9 38 FM_CPU_PWR_ DEBUG_N 39 MCI_CPU1_PTI10 40 DBP_POWER_BTN_N 41 MCI_CPU1_PTI11 42...

Страница 42: ...LK 14 GND 15 GND 16 GND 17 GND 18 NC 19 MCI_CPU2_PTI0 20 NC 21 MCI_CPU2_PTI1 22 NC 23 MCI_CPU2_PTI2 24 NC 25 MCI_CPU2_PTI3 26 NC 27 MCI_CPU2_PTI4 28 NC 29 MCI_CPU2_PTI5 30 NC Pin Definition Pin Definition 31 MCI_CPU2_PTI6 32 NC 33 MCI_CPU2_PTI7 34 NC 35 MCI_CPU2_PTI8 36 NC 37 MCI_CPU2_PTI9 38 NC 39 MCI_CPU2_PTI10 40 NC 41 MCI_CPU2_PTI11 42 PWRGD_CPU2_LVC3_ MIPI60 43 MCI_CPU2_PTI12 44 NC 45 MCI_CPU...

Страница 43: ...1 P3V3_CPLD 2 GND 3 CPLD_GPI01 4 CPLD_GPO01 5 CPLD_GPI02 6 CPLD_GPO02 7 CPLD_GPI03 8 CPLD_GPO03 VGA Connector Connector type 1x16 16 pin header Connector location J3 Pin Definition Pin Definition 1 VGA_VCC 2 GND 3 N C 4 SMB_BMC_DDC_SCL_R1 5 SMB_BMC_DDC_SDA_R1 6 N C 7 V_BMC_GFX_REAR_ VSYN_R3 8 GND 9 V_BMC_GFX_REAR_ HSYN_R3 10 NC 11 GND 12 V_BMC_GFX_REAR_ BLU_R1 13 GND 14 V_BMC_GFX_REAR_ GRN_R1 15 G...

Страница 44: ...D B15 GND A16 PE_SLOT4_CLK_DP B16 GND A17 PE_SLOT4_CLK_DN B17 GND A18 GND B18 GND Riser Left Connector Connector type PCIe x1 Connector location CN11 A1 B1 B18 A18 Pin Definition Pin Definition A1 P12V B1 P12V A2 P12V B2 P12V A3 P12V B3 P12V A4 GND B4 GND A5 P3V3 B5 P3V3 A6 P3V3 B6 P3V3 A7 P3V3 B7 P3V3 A8 P3V3 B8 P3V3 A9 P3V3_AUX B9 P3V3_AUX A10 GND B10 GND A11 GND B11 GND A12 GND B12 GND A13 PE_S...

Страница 45: ..._EXPANSION_CLK_DP B13 GND A14 PE_EXPANSION_CLK_DN B14 PE_SLOT8_TX_C_DN7 A15 GND B15 PE_SLOT8_TX_C_DP7 A16 PE_SLOT8_RX_DN7 B16 GND A17 PE_SLOT8_RX_DP7 B17 NC A18 GND B18 GND Pin Definition Pin Definition A19 NC B19 PE_SLOT8_TX_C_DN6 A20 GND B20 PE_SLOT8_TX_C_DP6 A21 PE_SLOT8_RX_DN6 B21 GND A22 PE_SLOT8_RX_DP6 B22 GND A23 GND B23 PE_SLOT8_TX_C_DN5 A24 GND B24 PE_SLOT8_TX_C_DP5 A25 PE_SLOT8_RX_DN5 B2...

Страница 46: ...4 PE_SLOT7_TX_C_DN6 A55 GND B55 PE_SLOT7_TX_C_DP6 A56 PE_SLOT7_RX_DN6 B56 GND A57 PE_SLOT7_RX_DP6 B57 GND A58 GND B58 PE_SLOT7_TX_C_DN5 A59 GND B59 PE_SLOT7_TX_C_DP5 Pin Definition Pin Definition A60 PE_SLOT7_RX_DN5 B60 GND A61 PE_SLOT7_RX_DP5 B61 GND A62 GND B62 PE_SLOT7_TX_C_DN4 A63 GND B63 PE_SLOT7_TX_C_DP4 A64 PE_SLOT7_RX_DN4 B64 GND A65 PE_SLOT7_RX_DP4 B65 GND A66 GND B66 PE_SLOT7_TX_C_DN3 A6...

Страница 47: ...LANB_DP B13 CLK_100M_I210_LANA_DP A14 CLK_100M_I210_LANB_DN B14 CLK_100M_I210_LANA_DN A15 GND B15 GND A16 PCIE_RX_LANB_DP B16 PCIE_TX_LANB_DP A17 PCIE_RX_LANB_DN B17 PCIE_TX_LANB_DN A18 GND B18 GND Pin Definition Pin Definition A19 PCIE_RX_LANA_DP B19 PCIE_TX_LANA_DP A20 PCIE_RX_LANA_DN B20 PCIE_TX_LANA_DN A21 GND B21 GND A22 IRQ_LVC3_WAKE_N B22 SMB_LANA_CLK_R A23 GND B23 SMB_LANA_DATA_R A24 PE_RS...

Страница 48: ...51 GND B51 GND A52 GND B52 GND A53 GND B53 GND A54 GND B54 GND A55 GND B55 GND A56 GND B56 GND A57 GND B57 LED_PCH_HDD A58 LED_PWR_STBY_ON B58 IO_ALERT_LED A59 NMI_BTN_N_L B59 POWER_ERROR_LED Pin Definition Pin Definition A60 FP_RST_BTN_N_L B60 STATUS1_LED A61 GND B61 STATUS2_LED A62 GND B62 GND A63 P3V3_CPLD B63 P3V3_BMC A64 GND B64 GND A65 P3V3 B65 P3V3 A66 P3V3 B66 P3V3 A67 P3V3 B67 P3V3 A68 GN...

Страница 49: ...K2_DN OA12 PE_SLOT_CLK3_DP OB12 PE_SLOT_CLK2_DP OA13 GND OB13 GND OA14 NO USE OB14 NO USE A1 GND B1 P12V A2 GND B2 P12V A3 GND B3 P12V A4 GND B4 P12V Pin Definition Pin Definition A5 GND B5 P12V A6 GND B6 P12V A7 SLOT_R_SCL B7 NO USE A8 SLOT_R_SDA B8 NO USE A9 NO USE B9 NO USE A10 GND B10 PE_SLOT_RST0_N A11 PE_SLOT_RST1_N B11 P3V3_SLOT A12 NO USE B12 NO USE A13 GND B13 GND A14 PE_SLOT_CLK1_DN B14 ...

Страница 50: ..._TX_C_DP7 A41 GND B41 GND A42 NO USE B42 NO USE A43 GND B43 GND A44 PE_SLOT_RX_DN8 B44 PE_SLOT_TX_C_DN8 A45 PE_SLOT_RX_DP8 B45 PE_SLOT_TX_C_DP8 A46 GND B46 GND Pin Definition Pin Definition A47 PE_SLOT_RX_DN9 B47 PE_SLOT_TX_C_DN9 A48 PE_SLOT_RX_DP9 B48 PE_SLOT_TX_C_DP9 A49 GND B49 GND A50 PE_SLOT_RX_DN10 B50 PE_SLOT_TX_C_DN10 A51 PE_SLOT_RX_DP10 B51 PE_SLOT_TX_C_DP10 A52 GND B52 GND A53 PE_SLOT_RX...

Страница 51: ...DN 24 NC 25 PCIE_TX_M2_R_2_DP 26 NC 27 GND 28 NC 29 PCIE_RX_M2_R_1_DN 30 NC 31 PCIE_RX_M2_R_1_DP 32 NC 33 GND 34 NC Pin Definition Pin Definition 35 PCIE_TX_M2_R_1_DN 36 NC 37 PCIE_TX_M2_R_1_DP 38 NGFF_DEVSLP 39 GND 40 N30398252 41 PCIE_RX_M2_R_0_DN 42 N30398249 43 PCIE_RX_M2_R_0_DP 44 NC 45 GND 46 NC 47 PCIE_TX_M2_R_0_DN 48 NC 49 PCIE_TX_M2_R_0_DP 50 PE_RST_M2_N 51 GND 52 FM_CLKREQ_M2_1_N 53 CLK_...

Страница 52: ...COOPOERLAKKE CPU2 ICELAKE COOPOERLAKKE SLOT1 _OCP PCIe Gen4 X16 SLOT2 _OCP PCIe Gen4 X16 PE0A 0 15 DMI 0 3 PCIE 4 0 X16 QAT DMI 3 0 PE1A 0 15 PE2A 0 15 PE3A 0 15 UPIX1 PE4 X8_Slot4 UPIX1 M M I D S P B T R O P P U S M M I D S P B T R O P P U S M M I D S P B T R O P P U S M M I D S P B T R O P P U S PE3A 0 15 UPIX1 PE0A 0 15 PE1A 0 15 PE2A 0 15 PCIE 4 0 X16 PCIE 4 0 X16 INTERPOSER CARD R PE4 X8_Slot...

Страница 53: ...hapter 3 System Setup Removing the Chassis Cover 1 The screws on the bottom and sides are used to secure the cover to the chassis Remove these screws and put them in a safe place for later use CAUTION CAUTION CAUTION Prior to removing the chassis cover make sure the unit s power is off and disconnected from the power sources to prevent electric shock or system damage Lift here Screws on the sides ...

Страница 54: ...ctions and noted items to avoid making unnecessary damages Make sure the power supply is switched off and disconnected from the power sources before replacing or adding LAN modules to prevent electric shock or system damage CAUTION CAUTION CAUTION 2 Use the handle provided and insert the handle into the two holes on the LAN module 1 Loosen the two screws on the LAN module Handle ...

Страница 55: ...nsferring data make sure you have connected an approved Optical Transceiver Module User needs to install appropriate and UL approved Laser Class I Transceivers rated 3 3Vdc max 1W 4 Insert the new LAN module into the slot and secure the module with the two screws 3 Once the handle is firmly secured in position pull the handle outwards to remove the LAN module ...

Страница 56: ...ockets the 3 covers need to be removed first The following instructions explain how to remove the 3 covers Removing the Front Cover 1 With the chassis cover removed locate the front cover and remove the screws on the left and right side of the cover Front Cover Right Side Left Side CAUTION CAUTION CAUTION Before installing or removing internal components on the mainboard please ensure that the AC ...

Страница 57: ...nternational Co Ltd All Rights Reserved 41 NSA 7150 7150A User Manual Chapter 3 System Setup 2 Remove the front cover Removing the Rear Cover 1 Locate the rear cover and remove the screws securing it as shown below Rear Cover ...

Страница 58: ...Rights Reserved 42 NSA 7150 7150A User Manual Chapter 3 System Setup 2 Remove the rear cover Removing the Middle Cover 1 Locate and remove the screws on the four corners of the middle cover Middle Cover Upper Right Upper Left Lower Left Lower Right ...

Страница 59: ...nternational Co Ltd All Rights Reserved 43 NSA 7150 7150A User Manual Chapter 3 System Setup 2 Remove the middle cover to access the CPU sockets Installing the CPU 1 Remove the protective cap on the CPU socket Protective Cap ...

Страница 60: ... Chapter 3 System Setup 2 Place the CPU into the processor carrier with the triangular mark on the CPU aligned to the triangular mark pin 1 indicator on the processor carrier 3 With the CPU placed into the processor carrier install the CPU onto the CPU socket Processor Carrier Triangular Mark ...

Страница 61: ...rocessor carrier then secure the screws using a T30 screwdriver Make sure to tighten the screws with a torque of 6 12 IN LB 5 Secure the four screws in the following order 1 2 3 and 4 T30 1 2 3 4 CAUTION CAUTION CAUTION Please ensure that the T30 screws are tightened with a torque of 6 12 IN LB Otherwise the motherboard may be damaged To uninstall the heat sink remove the screws in reverse order 4...

Страница 62: ... socket at an 90 degree angle Apply firm even pressure to each end of the module until it slips into the socket While pushing the module into position the locks will close automatically Note For information on the memory population rule please refer to pages 48 and 49 CAUTION CAUTION CAUTION Before installing or removing internal components on the mainboard please ensure that the AC power cord is ...

Страница 63: ...22 77 78 221 222 77 78 144 288 144 288 144 288 144 288 144 288 144 288 144 288 144 288 144 288 144 145 221 288 78 77 221 77 221 77 221 77 221 77 144 288 144 288 144 288 144 288 144 222 78 222 78 222 78 222 78 222 1 145 1 145 1 145 1 145 1 CH6 DIMM0 CH2 DIMM0 CH3 DIMM0 CH0 DIMM1 CH0 DIMM0 CH1 DIMM0 CH5 DIMM0 CH4 DIMM0 CH4 DIMM1 CH7 DIMM0 CH6 DIMM0 CH2 DIMM0 CH3 DIMM0 CH0 DIMM1 CH0 DIMM0 CH1 DIMM0 2...

Страница 64: ... 7150 7150A User Manual Chapter 3 System Setup DDR4 memory population table for the 3rd Gen Intel Xeon Scalable Processor is shown below If you use only one please refer to the table of corresponding color yellow for CPU0 and orange for CPU1 DDR4 Memory Population Table ...

Страница 65: ... Manual Chapter 3 System Setup DDR4 BSP memory population table for the 3rd Gen Intel Xeon Scalable Processor is shown below If you use only one please refer to the table of corresponding color yellow for CPU0 and orange for CPU1 DDR4 and Intel Optane Persistent Memory Population Table ...

Страница 66: ... Ltd All Rights Reserved 50 NSA 7150 7150A User Manual Chapter 3 System Setup Assembling the 2 5 Removable Drive Bay The 2 5 removable drive bay kit contains the parts pictured below 1 Locate the installation location for the drive bay kit ...

Страница 67: ...ternational Co Ltd All Rights Reserved 51 NSA 7150 7150A User Manual Chapter 3 System Setup 2 Install the two copper standoffs to the location circled below 3 Align the mounting holes on the base plate to the copper standoffs ...

Страница 68: ... Reserved 52 NSA 7150 7150A User Manual Chapter 3 System Setup 4 Secure the base plate to the standoffs with screws 5 Align the mounting holes on the drive bay enclosure to the mounting holes on the drive bay bracket Drive Bay Bracket Drive Bay Enclosure ...

Страница 69: ...s Reserved 53 NSA 7150 7150A User Manual Chapter 3 System Setup 6 Secure the drive bay enclosure to the bracket with screws 8 Fix the drive bay bracket to the base plate with screws 7 Repeat step 6 for securing the screws on the other side of the bracket ...

Страница 70: ...o Ltd All Rights Reserved 54 NSA 7150 7150A User Manual Chapter 3 System Setup 9 Connect the SATA data and power cables to the respective connectors on the board and the other ends of the cables to the connectors on the drive bay enclosure ...

Страница 71: ... Ltd All Rights Reserved 55 NSA 7150 7150A User Manual Chapter 3 System Setup Assembling the 3 5 Removable Drive Bay The 3 5 removable drive bay kit contains the parts pictured below 1 Locate the installation location for the drive bay kit ...

Страница 72: ...ternational Co Ltd All Rights Reserved 56 NSA 7150 7150A User Manual Chapter 3 System Setup 2 Install the two copper standoffs to the location circled below 3 Align the mounting holes on the base plate to the copper standoffs ...

Страница 73: ...nternational Co Ltd All Rights Reserved 57 NSA 7150 7150A User Manual Chapter 3 System Setup 4 Secure the base plate to the standoffs with screws 5 Push the eject button on the HDD drive tray to release the latch Eject button ...

Страница 74: ...System Setup 6 Grab on the latch and pull the drive tray out gently Latch 7 Place the SATA drive onto the tray and align the mounting holes on the drive with the mounting holes on the tray then secure the drive in place with screws 8 Repeat step 7 for securing the screws on the other side of the HDD tray ...

Страница 75: ...d All Rights Reserved 59 NSA 7150 7150A User Manual Chapter 3 System Setup 9 Slide the tray back into the drive bay enclosure and push firmly until you hear a distinctive click sound 10 Fix the drive bay enclosure to the base plate with screws ...

Страница 76: ... Ltd All Rights Reserved 60 NSA 7150 7150A User Manual Chapter 3 System Setup 11 Connect the SATA data and power cables to the respective connectors on the board and the other ends of the cables to the connectors on the drive bay enclosure ...

Страница 77: ...stem is configured with the values found in CMOS With easy to use pull down menus you can configure such items as Hard drives diskette drives and peripherals Video display type and display options Password protection from unauthorized use Power management features The settings made in the setup program affect how the computer performs It is important therefore first to try to understand all the se...

Страница 78: ...ntered the error will be reported in one of two different ways If the error occurs before the display device is initialized a series of beeps will be transmitted If the error occurs after the display device is initialized the screen will display the error message Powering on the computer and immediately pressing allows you to enter Setup Legends Key Function Moves the highlight left or right to se...

Страница 79: ...setup screen it indicates that there are more available fields not shown on the screen Use the up and down arrow keys to scroll through all the available fields Submenu When appears on the left of a particular field it indicates that a submenu which contains additional options are available for that field To display the submenu move the highlight to that field and press ...

Страница 80: ... Exit ESC Exit Set the Time Use Tab to switch between Time elements BIOS Information BIOS Vendor Core Version Compliancy Project Version Build Date and Time Current BIOS Access Level Platform Information Platform Processor PCH RC Revision BIOS ACM SINIT ACM Memory Information Total Memory System Date System Time American Megatrends 5 21 UEFI 2 8 PI 1 7 G790T 0 40 x64 01 15 2021 13 56 41 BIOS1 Admi...

Страница 81: ...F4 Save Exit ESC Exit Enables or Disables BIOS support for security device O S will not show Security Device TCG EFI protocol and INT1A interface will not be available Configuration Security Device Support NO Security Device Enable Security Device Support Enables or disables BIOS support for security device O S will not show Security Device TCG EFI protocol and INT1A interface will not be availabl...

Страница 82: ...2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Set Parameters of Serial Port 1 COMA NCT6686D Super IO Configuration Super IO Chip Serial Port 1 Configuration Serial Port 2 Configuration NCT6686D Serial Port 1 Configuration This section is used to configure serial port 1 Serial Port Enables or disables the serial port Change Settings Selects an optimal setting for the Super IO device...

Страница 83: ...O device Device Mode Configures the operating mode of the serial port Advanced Version 2 21 1279 Copyright C 2021 American Megatrends Inc Aptio Setup Utility Copyright C 2021 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Enable or Disable Serial Port COM Serial Port 2 Configuration Serial Por...

Страница 84: ..._CPU1 47 C 44 C 36 C 33 C N A N A N A 4255 RPM 4067 RPM 12 288 V 4 979 V 1 056 V 1 808 V 1 808 V Advanced Version 2 21 1279 Copyright C 2021 American Megatrends Inc Aptio Setup Utility Copyright C 2021 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Fan1 Speed Fan2 Speed Fan3 Speed Fan4 Speed F...

Страница 85: ... computers should have the same or compatible settings Advanced Version 2 21 1279 Copyright C 2021 American Megatrends Inc Aptio Setup Utility Copyright C 2021 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Emulation ANSI Extended ASCII char set VT100 ASCII char set VT100 Extends VT100 to supp...

Страница 86: ...s is to capture the terminal data Resolution 100x31 Enables or disables extended terminal resolution Putty KeyPad Selects the Putty keyboard emulation type PCI Subsystem Settings This section is used to configure the PCI Advanced Version 2 21 1279 Copyright C 2021 American Megatrends Inc Aptio Setup Utility Copyright C 2021 American Megatrends Inc Select Screen Select Item Enter Select Change Opt ...

Страница 87: ...rican Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Mass storage device emulation type AUTO enumerates devices according to their media format Optical drives are emulated as CDROM drives with no media will be emulated USB hardware delays and time outs USB transfer time out Device reset time out Device...

Страница 88: ...or a Hub port the delay is taken from Hub descriptor Mass Storage Devices Selects the mass storage device emulation type Network Stack Configuration This section is used to configure the network stack Advanced Version 2 21 1279 Copyright C 2021 American Megatrends Inc Aptio Setup Utility Copyright C 2021 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 P...

Страница 89: ...r Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Enable Disable CSM Support Compatibility Support Module Configuration CSM Support CSM16 Module Version Boot option filter Option ROM execution Network Storage Video Other PCI devices Enabled 07 84 UEFI and Legacy Do not launch UEFI Legacy Do not launch CSM Configuration This section is used to config...

Страница 90: ...ion 2 21 1279 Copyright C 2021 American Megatrends Inc Aptio Setup Utility Copyright C 2021 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Total CPU Number 96 CPU0 CPUID 000606A4 Stepping 4 MicroCodeRev 0B000280 PlatformID 0000000000000000 CoreFreq MHz 2600 ActCpuFreq MHz 2600 CPU1 CPUID 00060...

Страница 91: ...Aptio Setup Utility Copyright C 2021 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Enable Disable Intel R IO Controller Hub devices PCH Configuration PCH Devices PCI Express Configuration PCH SATA Configuration PCH sSATA Configuration USB Configuration Server Mgmt Advanced Platform Configurat...

Страница 92: ... 2021 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Enable Spread Spectrum only affects external clock generator External SSC Enable CK420 PCH state after G3 CPU VR CONFIG Power Supply Type Pcie Pll SSC Shutdown Policy Server Mgmt Advanced Platform Configuration Socket Configuration Main Disa...

Страница 93: ...able Disable Hard Disk Drive Unknown Not Installed PCH SATA Configuration SATA Controller s Enables or disables the SATA controller Configure SATA as Configures the SATA mode AHCI This option configures the Serial ATA drives to use AHCI Advanced Host Controller Interface AHCI allows the storage driver to enable the advanced Serial ATA features which will increase storage performance Port 0 Enables...

Страница 94: ...able Disable Disable Hard Disk Drive Unknown PCH sSATA Configuration sSATA Controller s Enables or disables the SATA controller Configure sSATA as Configures the SATA mode AHCI This option configures the Serial ATA drives to use AHCI Advanced Host Controller Interface AHCI allows the storage driver to enable the advanced Serial ATA features which will increase storage performance SATA Test Mode En...

Страница 95: ...Configuration Socket Configuration Main Disable Disable Server ME Configuration Displays information of the firmware installed in the system Version 2 21 1279 Copyright C 2021 American Megatrends Inc Aptio Setup Utility Copyright C 2021 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit General ME...

Страница 96: ...rocessor Settings Processor Configuration Common RefCode Configuration UPI Configuration Memory Configuration IIO Configuration Advanced Power Management Configuration Server Mgmt Advanced Platform Configuration Socket Configuration Main Processor Configuration Enters the Processor Configuration submenu Common RefCode Configuration Enters the Common RefCode Configuration submenu UPI Configuration ...

Страница 97: ...tio Setup Utility Copyright C 2021 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Enables the Vanderpool Technology takes effect after reboot L1 Cache RAM Per Core 80KB 80KB L2 Cache RAM Per Core 1280KB 1280KB L3 Cache RAM Per 36864KB 36864KB Package Processor 0 Version Genuine Intel R CPU 000...

Страница 98: ...C 2021 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit 0 Enable all cores FFFFFFF Disable all cores NOTE At least one core per CPU must be enabled Disabling all cores is an invalid configuration CPU Socket 0 Configuration Available Bitmap 000000000EDFDF7F Core Disable Bitmap Hex Server Mgmt Adv...

Страница 99: ...on MMCFG Base Configures the memory mapped configuration MMCFG base address MMCFG Size Configures the MMCFG size MMIO High Base Configures the base memory size of MMIO high base MMIO High Granularity Size Configures the high memory size of MMIO high base Version 2 21 1279 Copyright C 2021 American Megatrends Inc Aptio Setup Utility Copyright C 2021 American Megatrends Inc Select Screen Select Item...

Страница 100: ...Enables or disables Non Uniform Memory Access support Virtual Numa Enables or disables Virtual Numa support UMA Based Clustering Configures the option for UMA Based Clustering Publish SRAT Enables or disables SRAT Static Resource Affinity Table SRAT Memory Hot Plug Enables or disables SRAT Memory Hot Plugging SRAT CPU Hot Plug Enables or disables SRAT CPU Hot Plugging ...

Страница 101: ...et Configuration Main Version 2 21 1279 Copyright C 2021 American Megatrends Inc Aptio Setup Utility Copyright C 2021 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Uncore Status Help Uncore General Configuration Uncore Status Link Speed Mode Link Frequency Select Server Mgmt Advanced Platform...

Страница 102: ...Platform Configuration Socket Configuration Main 2 2 Fast 11 2 GT s 90000000 FBFFFFFF 0000000000000000 0 80000000 10000000 Uncore Status Displays information on the current uncore configuration Version 2 21 1279 Copyright C 2021 American Megatrends Inc Aptio Setup Utility Copyright C 2021 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F...

Страница 103: ...0 configuration submenu CPU 0 UPI Port 1 Enters the CPU 0 UPI Port 1 configuration submenu CPU 0 UPI Port 2 Enters the CPU 0 UPI Port 2 configuration submenu Version 2 21 1279 Copyright C 2021 American Megatrends Inc Aptio Setup Utility Copyright C 2021 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ES...

Страница 104: ...0 configuration submenu CPU 2 UPI Port 1 Enters the CPU 2 UPI Port 1 configuration submenu CPU 2 UPI Port 2 Enters the CPU 2 UPI Port 2 configuration submenu Version 2 21 1279 Copyright C 2021 American Megatrends Inc Aptio Setup Utility Copyright C 2021 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ES...

Страница 105: ...ket Configuration Main No 7F Auto CPU 0 UPI Port 0 Link Disable Enables or disables the UPI link Current UPI Link Speed Configures the current UPI link speed Version 2 21 1279 Copyright C 2021 American Megatrends Inc Aptio Setup Utility Copyright C 2021 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ES...

Страница 106: ...ket Configuration Main No 7F Auto CPU 0 UPI Port 2 Link Disable Enables or disables the UPI link Current UPI Link Speed Configures the current UPI link speed Version 2 21 1279 Copyright C 2021 American Megatrends Inc Aptio Setup Utility Copyright C 2021 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ES...

Страница 107: ...ket Configuration Main No 7F Auto CPU 1 UPI Port 1 Link Disable Enables or disables the UPI link Current UPI Link Speed Configures the current UPI link speed Version 2 21 1279 Copyright C 2021 American Megatrends Inc Aptio Setup Utility Copyright C 2021 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ES...

Страница 108: ...ket Configuration Main No 7F Auto CPU 2 UPI Port 0 Link Disable Enables or disables the UPI link Current UPI Link Speed Configures the current UPI link speed Version 2 21 1279 Copyright C 2021 American Megatrends Inc Aptio Setup Utility Copyright C 2021 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ES...

Страница 109: ...ket Configuration Main No 7F Auto CPU 2 UPI Port 2 Link Disable Enables or disables the UPI link Current UPI Link Speed Configures the current UPI link speed Version 2 21 1279 Copyright C 2021 American Megatrends Inc Aptio Setup Utility Copyright C 2021 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ES...

Страница 110: ...ket Configuration Main No 7F Auto CPU 3 UPI Port 1 Link Disable Enables or disables the UPI link Current UPI Link Speed Configures the current UPI link speed Version 2 21 1279 Copyright C 2021 American Megatrends Inc Aptio Setup Utility Copyright C 2021 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ES...

Страница 111: ...ogy Memory Map Server Mgmt Advanced Platform Configuration Socket Configuration Main POR Enforce Supported Populations Memory Configuration Enforce POR Configures the options for Enforce Plan of Record When enabled Plan of Record restrictions for DDR4 frequency and voltage programming is enforced Enforce Population POR Enables or disables Enforce Population POR Version 2 21 1279 Copyright C 2021 A...

Страница 112: ...mode for volatile memory For 2LM memory mode BIOS will try to configure 2LM but if BIOS is unable to configure 2LM volatile memory mode will fall Volatile Memory Mode AppDirect cache eADR Support Server Mgmt Advanced Platform Configuration Socket Configuration Main 2LM Disabled Disable Memory Map Volatile Memory Mode Configures 1LM or 2LM mode for volatile memory For 2LM memory mode BIOS will try ...

Страница 113: ...21 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Selects PCIe port Bifurcation for selected slot s IOU0 IIO PCIe Br1 IOU1 IIO PCIe Br2 IOU2 IIO PCIe Br3 IOU3 IIO PCIe Br4 IOU4 IIO PCIe Br5 Enable PCI E Completion Timeout Per Port Sck0 RP Correctable Err Sck0 RP NonFatal Uncorrectable Err Sck0...

Страница 114: ... Version 2 21 1279 Copyright C 2021 American Megatrends Inc Aptio Setup Utility Copyright C 2021 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Choose Link Speed for this PCIe port Port 0 DMI Link Speed PCI E Port DeEmphasis PCI E Port Link Status PCI E Port Link Max PCI E Port Link Speed PCI ...

Страница 115: ...isable Disable Disable Disable Disable Disable KTI Option Yes Port 0 DMI Compliance Mode Enables or disables the Compliance Mode EOI Enables or disables EOI Fatal Err Over Enables or disables forced fatal error Non Fatal Err Over Enables or disables forced non fatal error Corr Err Over Enables forced correctable error ACPI PME Interrupt Enables or disables ACPI PME Interrupts P2P Memory Read Enabl...

Страница 116: ...ed Override Max Link Width PCI E Port DeEmphasis PCI E Port Link Status PCI E Port Link Max PCI E Port Link Speed PCI E Port Clocking PCI E Port Clock Gating Data Link Feature Exchange PCI E Port MPSS P2P Memory Read PME to ACK PM ACPI Mode Unsupported Request Alternate TxEq SRIS ECRC Generation ECRC Check SERRE Server Mgmt Advanced Platform Configuration Socket Configuration Main Auto Auto Auto 3...

Страница 117: ... Port 1A PCI E Port Clocking Configures the option for PCI E Port Clocking PCI E Port Clock Gating Enables or disables PCIe clock gating for each root port Data Link Feature Exchange Enables or disables Data Link Feature Exchange in PCIe 4 0 PCI E Port MPSS Configures the option for max payload size supported for PCI E port P2P Memory Read Enables or disables P2P Memory Read PME to ACK Enables or ...

Страница 118: ...d hide its CFG space Port 2A PCI E Port Link Speed Override Max Link Width PCI E Port DeEmphasis PCI E Port Link Status PCI E Port Link Max PCI E Port Link Speed PCI E Port Clocking PCI E Port Clock Gating Data Link Feature Exchange PCI E Port MPSS PCI E Port D state PCI E ASPM Support MSI PCI E Extended Sync PCI E Detect Wait Time Compliance Mode EOI Fatal Err Over Non Fatal Err Over Server Mgmt ...

Страница 119: ...ables forced correctable error ACPI PME Interrupt Enables or disables ACPI PME Interrupts P2P Memory Read Enables or disables P2P Memory Read PME to ACK Enables or disables PME to ACK messages PM ACPI Mode Enables or disables PM ACPI Mode Unsupported Request Enables or disables unsupported request reporting Alternate TxEq Enables or disables Alternate TxEq SRIS Enables or disables SRIS ECRC Genera...

Страница 120: ...rride Max Link Width PCI E Port DeEmphasis PCI E Port Link Status PCI E Port Link Max PCI E Port Link Speed PCI E Port Clocking PCI E Port Clock Gating Data Link Feature Exchange PCI E Port MPSS PCI E Port D state PCI E ASPM Support MSI PCI E Extended Sync PCI E Detect Wait Time Compliance Mode EOI Fatal Err Over Non Fatal Err Over Server Mgmt Advanced Platform Configuration Socket Configuration M...

Страница 121: ...es forced non fatal error Corr Err Over Enables forced correctable error ACPI PME Interrupt Enables or disables ACPI PME Interrupts P2P Memory Read Enables or disables P2P Memory Read PME to ACK Enables or disables PME to ACK messages PM ACPI Mode Enables or disables PM ACPI Mode Unsupported Request Enables or disables unsupported request reporting Alternate TxEq Enables or disables Alternate TxEq...

Страница 122: ...d hide its CFG space Port 4A PCI E Port Link Speed Override Max Link Width PCI E Port DeEmphasis PCI E Port Link Status PCI E Port Link Max PCI E Port Link Speed PCI E Port Clocking PCI E Port Clock Gating Data Link Feature Exchange PCI E Port MPSS PCI E Port D state PCI E ASPM Support MSI PCI E Extended Sync PCI E Detect Wait Time Compliance Mode EOI Fatal Err Over Non Fatal Err Over Server Mgmt ...

Страница 123: ...ables forced correctable error ACPI PME Interrupt Enables or disables ACPI PME Interrupts P2P Memory Read Enables or disables P2P Memory Read PME to ACK Enables or disables PME to ACK messages PM ACPI Mode Enables or disables PM ACPI Mode Unsupported Request Enables or disables unsupported request reporting Alternate TxEq Enables or disables Alternate TxEq SRIS Enables or disables SRIS ECRC Genera...

Страница 124: ...rride Max Link Width PCI E Port DeEmphasis PCI E Port Link Status PCI E Port Link Max PCI E Port Link Speed PCI E Port Clocking PCI E Port Clock Gating Data Link Feature Exchange PCI E Port MPSS PCI E Port D state PCI E ASPM Support MSI PCI E Extended Sync PCI E Detect Wait Time Compliance Mode EOI Fatal Err Over Non Fatal Err Over Server Mgmt Advanced Platform Configuration Socket Configuration M...

Страница 125: ...es forced non fatal error Corr Err Over Enables forced correctable error ACPI PME Interrupt Enables or disables ACPI PME Interrupts P2P Memory Read Enables or disables P2P Memory Read PME to ACK Enables or disables PME to ACK messages PM ACPI Mode Enables or disables PM ACPI Mode Unsupported Request Enables or disables unsupported request reporting Alternate TxEq Enables or disables Alternate TxEq...

Страница 126: ...d hide its CFG space Port 5A PCI E Port Link Speed Override Max Link Width PCI E Port DeEmphasis PCI E Port Link Status PCI E Port Link Max PCI E Port Link Speed PCI E Port Clocking PCI E Port Clock Gating Data Link Feature Exchange PCI E Port MPSS PCI E Port D state PCI E ASPM Support MSI PCI E Extended Sync PCI E Detect Wait Time Compliance Mode EOI Fatal Err Over Non Fatal Err Over Server Mgmt ...

Страница 127: ...ables forced correctable error ACPI PME Interrupt Enables or disables ACPI PME Interrupts P2P Memory Read Enables or disables P2P Memory Read PME to ACK Enables or disables PME to ACK messages PM ACPI Mode Enables or disables PM ACPI Mode Unsupported Request Enables or disables unsupported request reporting Alternate TxEq Enables or disables Alternate TxEq SRIS Enables or disables SRIS ECRC Genera...

Страница 128: ...rride Max Link Width PCI E Port DeEmphasis PCI E Port Link Status PCI E Port Link Max PCI E Port Link Speed PCI E Port Clocking PCI E Port Clock Gating Data Link Feature Exchange PCI E Port MPSS PCI E Port D state PCI E ASPM Support MSI PCI E Extended Sync PCI E Detect Wait Time Compliance Mode EOI Fatal Err Over Non Fatal Err Over Server Mgmt Advanced Platform Configuration Socket Configuration M...

Страница 129: ...es forced non fatal error Corr Err Over Enables forced correctable error ACPI PME Interrupt Enables or disables ACPI PME Interrupts P2P Memory Read Enables or disables P2P Memory Read PME to ACK Enables or disables PME to ACK messages PM ACPI Mode Enables or disables PM ACPI Mode Unsupported Request Enables or disables unsupported request reporting Alternate TxEq Enables or disables Alternate TxEq...

Страница 130: ...21 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Selects PCIe port Bifurcation for selected slot s IOU0 IIO PCIe Br1 IOU1 IIO PCIe Br2 IOU2 IIO PCIe Br3 IOU3 IIO PCIe Br4 Enable PCI E Completion Timeout Per Port PCI E Completion Timeout Value Sck1 RP Correctable Err Sck1 RP NonFatal Uncorrect...

Страница 131: ...can Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit In auto mode the BIOS will remove the EXP port if there is no device or errors on that device and the device is not HP capable Disable is used to disable the port and hide its CFG space Port 1A PCI E Port Link Speed Override Max Link Width PCI E Port D...

Страница 132: ... Port 1A PCI E Port Clocking Configures the option for PCI E Port Clocking PCI E Port Clock Gating Enables or disables PCIe clock gating for each root port Data Link Feature Exchange Enables or disables Data Link Feature Exchange in PCIe 4 0 PCI E Port MPSS Configures the option for max payload size supported for PCI E port P2P Memory Read Enables or disables P2P Memory Read PME to ACK Enables or ...

Страница 133: ...rride Max Link Width PCI E Port DeEmphasis PCI E Port Link Status PCI E Port Link Max PCI E Port Link Speed PCI E Port Clocking PCI E Port Clock Gating Data Link Feature Exchange PCI E Port MPSS PCI E Port D state PCI E ASPM Support MSI PCI E Extended Sync PCI E Detect Wait Time Compliance Mode EOI Fatal Err Over Non Fatal Err Over Server Mgmt Advanced Platform Configuration Socket Configuration M...

Страница 134: ...es forced non fatal error Corr Err Over Enables forced correctable error ACPI PME Interrupt Enables or disables ACPI PME Interrupts P2P Memory Read Enables or disables P2P Memory Read PME to ACK Enables or disables PME to ACK messages PM ACPI Mode Enables or disables PM ACPI Mode Unsupported Request Enables or disables unsupported request reporting Alternate TxEq Enables or disables Alternate TxEq...

Страница 135: ...d hide its CFG space Port 2A PCI E Port Link Speed Override Max Link Width PCI E Port DeEmphasis PCI E Port Link Status PCI E Port Link Max PCI E Port Link Speed PCI E Port Clocking PCI E Port Clock Gating Data Link Feature Exchange PCI E Port MPSS PCI E Port D state PCI E ASPM Support MSI PCI E Extended Sync PCI E Detect Wait Time Compliance Mode EOI Fatal Err Over Non Fatal Err Over Server Mgmt ...

Страница 136: ...ables forced correctable error ACPI PME Interrupt Enables or disables ACPI PME Interrupts P2P Memory Read Enables or disables P2P Memory Read PME to ACK Enables or disables PME to ACK messages PM ACPI Mode Enables or disables PM ACPI Mode Unsupported Request Enables or disables unsupported request reporting Alternate TxEq Enables or disables Alternate TxEq SRIS Enables or disables SRIS ECRC Genera...

Страница 137: ...rride Max Link Width PCI E Port DeEmphasis PCI E Port Link Status PCI E Port Link Max PCI E Port Link Speed PCI E Port Clocking PCI E Port Clock Gating Data Link Feature Exchange PCI E Port MPSS PCI E Port D state PCI E ASPM Support MSI PCI E Extended Sync PCI E Detect Wait Time Compliance Mode EOI Fatal Err Over Non Fatal Err Over Server Mgmt Advanced Platform Configuration Socket Configuration M...

Страница 138: ...es forced non fatal error Corr Err Over Enables forced correctable error ACPI PME Interrupt Enables or disables ACPI PME Interrupts P2P Memory Read Enables or disables P2P Memory Read PME to ACK Enables or disables PME to ACK messages PM ACPI Mode Enables or disables PM ACPI Mode Unsupported Request Enables or disables unsupported request reporting Alternate TxEq Enables or disables Alternate TxEq...

Страница 139: ...d hide its CFG space Port 4A PCI E Port Link Speed Override Max Link Width PCI E Port DeEmphasis PCI E Port Link Status PCI E Port Link Max PCI E Port Link Speed PCI E Port Clocking PCI E Port Clock Gating Data Link Feature Exchange PCI E Port MPSS PCI E Port D state PCI E ASPM Support MSI PCI E Extended Sync PCI E Detect Wait Time Compliance Mode EOI Fatal Err Over Non Fatal Err Over Server Mgmt ...

Страница 140: ...ables forced correctable error ACPI PME Interrupt Enables or disables ACPI PME Interrupts P2P Memory Read Enables or disables P2P Memory Read PME to ACK Enables or disables PME to ACK messages PM ACPI Mode Enables or disables PM ACPI Mode Unsupported Request Enables or disables unsupported request reporting Alternate TxEq Enables or disables Alternate TxEq SRIS Enables or disables SRIS ECRC Genera...

Страница 141: ...rride Max Link Width PCI E Port DeEmphasis PCI E Port Link Status PCI E Port Link Max PCI E Port Link Speed PCI E Port Clocking PCI E Port Clock Gating Data Link Feature Exchange PCI E Port MPSS PCI E Port D state PCI E ASPM Support MSI PCI E Extended Sync PCI E Detect Wait Time Compliance Mode EOI Fatal Err Over Non Fatal Err Over Server Mgmt Advanced Platform Configuration Socket Configuration M...

Страница 142: ...es forced non fatal error Corr Err Over Enables forced correctable error ACPI PME Interrupt Enables or disables ACPI PME Interrupts P2P Memory Read Enables or disables P2P Memory Read PME to ACK Enables or disables PME to ACK messages PM ACPI Mode Enables or disables PM ACPI Mode Unsupported Request Enables or disables unsupported request reporting Alternate TxEq Enables or disables Alternate TxEq...

Страница 143: ...d hide its CFG space Port 5A PCI E Port Link Speed Override Max Link Width PCI E Port DeEmphasis PCI E Port Link Status PCI E Port Link Max PCI E Port Link Speed PCI E Port Clocking PCI E Port Clock Gating Data Link Feature Exchange PCI E Port MPSS PCI E Port D state PCI E ASPM Support MSI PCI E Extended Sync PCI E Detect Wait Time Compliance Mode EOI Fatal Err Over Non Fatal Err Over Server Mgmt ...

Страница 144: ...ables forced correctable error ACPI PME Interrupt Enables or disables ACPI PME Interrupts P2P Memory Read Enables or disables P2P Memory Read PME to ACK Enables or disables PME to ACK messages PM ACPI Mode Enables or disables PM ACPI Mode Unsupported Request Enables or disables unsupported request reporting Alternate TxEq Enables or disables Alternate TxEq SRIS Enables or disables SRIS ECRC Genera...

Страница 145: ... Tables Intel VT for Directed I O VT d Intel VT for Directed I O DMA Control Opt In Flag Interrupt Remapping X2APIC Opt Out Pre boot DMA Protection Server Mgmt Advanced Platform Configuration Socket Configuration Main Enable Disable Auto Disable Disable Intel VT for Directed I O VT d Intel VT for Directed I O Enables or disables Intel Virtualization Technology for Directed I O VT d by reporting th...

Страница 146: ...le Disable EIST P States CPU P State Control Uncore Freq Scaling AVX License Pre Grant Override SpeedStep Pstates Dynamic SST PP Intel SST PP Base Config 3 Config 4 Core Count 24 24 16 Current P1 Ratio 0 26 22 27 Package TDP W 220 185 185 Tjmax 108 097 104 Activate SST BF Configure SST BF EIST PSD Function Boot performance mode Energy Efficient Turbo CPU Flex Ratio Override CPU Core Flex Ratio GPS...

Страница 147: ...faults F4 Save Exit ESC Exit Parameter used to tune how far below local socket frequency remote socket frequency is allowed to be Also impacts rate at which frequency drops when feature disengages Perf P Limit Perf P Limit Differential Perf P Limit Clip Perf P Limit Threshold Perf P Limit Server Mgmt Advanced Platform Configuration Socket Configuration Main 1F F Enable 1 Perf P Limit Differential ...

Страница 148: ...U C1 auto undemotion CPU C6 report Enhanced Halt State C1E OS ACPI Cx Server Mgmt Advanced Platform Configuration Socket Configuration Main Enable Enable Enable Auto Disable ACPI C2 Advanced Power Management Configuration Enable Monitor MWAIT Enables or disables monitoring and MWAIT instructions CPU C1 auto demotion Enables or disables CPU C1 auto demotion CPU C1 auto undemotion Enables or disable...

Страница 149: ...bles interfaces to communicate with BMC Power Control Policy Configures the options for power control policy Version 2 21 1279 Copyright C 2021 American Megatrends Inc Aptio Setup Utility Copyright C 2021 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Change this to enable or disable event log...

Страница 150: ...lity Copyright C 2021 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Select to configure LAN channel parameters statically or dynamically by BIOS or BMC Unspecified option will not modify any BMC network parameters during BIOS phase BMC network configuration Configure IPv4 support Lan channel ...

Страница 151: ...65535 0xFFFF means indefinite waiting Bootup NumLock State This allows you to determine the default state of the numeric keypad By default the system boots up with NumLock on wherein the function of the numeric keypad is the number keys When set to Off the function of the numeric keypad is the arrow keys Save Exit Boot Save Exit Boot Security Version 2 21 1279 Copyright C 2021 American Megatrends ...

Страница 152: ...y and reset without saving the changes select this field then press Enter You may be prompted to confirm again before exiting Restore Defaults To restore the BIOS to default settings select this field then press Enter A dialog box will appear Confirm by selecting Yes Launch EFI Shell from Filesystem Device To launch EFI shell from a filesystem device select this field and press Enter Save Exit Boo...

Отзывы: