Installing a SO-DIMM Memory Module

2. Push the module down until the clips on both sides of the socket lock 

into position. You will hear a distinctive “click” sound, indicating the 
module is correctly locked into position.

1. Insert the module into the socket at an approximately 30 degrees angle. 

Apply firm even pressure to each end of the module until it slips into the 
socket. The gold-plated connector on the edge of the module will almost     
completely disappear inside the socket.

Memory module

Содержание NDiS B426

Страница 1: ...NEXCOM International Co Ltd NEXCOM International Co Ltd Published June 2016 www nexcom com Interactive Signage Platform Business Unit Digital Signage Platform NDiS B426 User Manual ...

Страница 2: ...troduction NDiS B426 1 Overview 1 Key Features 1 Hardware Specifications 2 Knowing Your NDiS B426 3 Front Panel 3 Rear Panel 4 Mechanical Dimensions 5 Chapter 2 Jumpers and Connectors Before You Begin 6 Precautions 6 Jumper Settings 7 Location of the Jumpers and Connectors 8 Top View 8 Bottom View 9 Connector Button Table 10 Header Wafer Table 10 Chapter 3 System Setup Installing a SATA HDD 11 Ins...

Страница 3: ...Copyright 2016 NEXCOM International Co Ltd All Rights Reserved iii NDiS B426 User Manual Content Power 28 Security 30 Boot 30 Save Exit 32 Appendix A Watchdog 33 ...

Страница 4: ...of NEXCOM International Co Ltd All other product names mentioned herein are registered trademarks of their respective owners Regulatory Compliance Statements This section provides the FCC compliance statement for Class A devices and describes how to keep the system CE compliant Declaration of Conformity FCC This equipment has been tested and verified to comply with the limits for a Class A digital...

Страница 5: ...nd Polybrominated diphenyl Ethers PBDE 0 1 or 1 000ppm In order to meet the RoHS compliant directives NEXCOM has established an engineering and manufacturing task force to implement the introduction of green products The task force will ensure that we follow the standard NEXCOM development procedure and that all the new RoHS components and new manufacturing processes maintain the highest industry ...

Страница 6: ...fective products making sure it is durable enough to be resistant against further damage and deterioration during transportation In case of damages occurred during transportation the repair is treated as Out of Warranty Any products returned by NEXCOM to other locations besides the customers site will bear an extra charge and will be billed to the customer Repair Service Charges for Out of Warrant...

Страница 7: ...and power supply are inconsistent with these instructions or the instructions for accessory modules contact the supplier to find out how you can ensure that your computer meets safety and regulatory requirements Cautions Electrostatic discharge ESD can damage system components Do the described procedures only at an ESD workstation If no such station is available you can provide some ESD protection...

Страница 8: ...e the soft metal or plastic parts of the connectors Safety Information Before installing and using the device note the following precautions Read all instructions carefully Do not place the unit on an unstable surface cart or stand Follow all warnings and cautions in this manual When replacing parts ensure that your service technician uses parts specified by the manufacturer Avoid using the system...

Страница 9: ...he voltage and current rating marked on the product 10 All cautions and warnings on the equipment should be noted 11 If the equipment is not used for a long time disconnect it from the power source to avoid damage by transient overvoltage 12 Never pour any liquid into an opening This may cause fire or electrical shock 13 Never open the equipment For safety reasons the equipment should be opened on...

Страница 10: ...ion of the installed software operating system version application software etc A complete description of the problem The exact wordings of the error messages Warning 1 Handling the unit carry the unit with both hands and handle it with care 2 Maintenance to keep the unit clean use only approved cleaning products or clean with a dry cloth Conventions Used in this Manual Warning Information about c...

Страница 11: ...920 Chung Cheng Rd ZhongHe District New Taipei City 23586 Taiwan R O C Tel 886 2 8226 7796 Fax 886 2 8226 7792 Email sales nexcom com tw www nexcom com tw NEXCOM Intelligent Systems Taichung Office 16F No 250 Sec 2 Chongde Rd Beitun Dist Taichung City 406 R O C Tel 886 4 2249 1179 Fax 886 4 2249 1172 Email sales nexcom com tw www nexcom com tw Japan NEXCOM Japan 9F Tamachi Hara Bldg 4 11 5 Shiba M...

Страница 12: ...mitalia it NEXCOM Shanghai Room 603 604 Huiyinmingzun Plaza Bldg 1 No 609 Yunlin East Rd Shanghai 200333 China Tel 86 21 5278 5868 Fax 86 21 3251 6358 Email sales nexcom cn www nexcom cn NEXCOM Surveillance Technology Room 209 Floor 2 East No 2 Science Technology industrial park of privately owned enterprises Xili Nanshan Dist Shenzhen 518055 China Tel 86 755 8364 7768 Fax 86 755 8364 7738 Email s...

Страница 13: ...er Manual Preface Package Contents Before continuing verify that the NDiS B426 package that you received is complete Your package should have all the items listed in the following table Item Name Qty 1 Power Adapter 1 2 HDD Bracket Kit 1 3 Driver DVD 1 Power Adapter HDD Bracket Kit ...

Страница 14: ...following below provides ordering information for NDiS B426 Barebone NDiS B426 P N 10WOOB42600X0 Intel Celeron Processor 3855U with Nvidia GT 730M GPU Optional VESA Mount Kit P N 10W00B42601X0 1 x VESA Mount Bracket 10 x Screws Wall Mount Kit P N 10W00B42602X0 2 x Wall Mount Bracket 4 x Screws VESA Mount Kit Wall Mount Kit ...

Страница 15: ...output 4K2K resolution support Compact and slim design H 29mm NDiS B426 Overview Powered by new generation Intel Celeron Processor 3855U and NVIDIA GeForce GT 730M NDiS B426 digital signage player can handle 4K2K multimedia contents With Intel processor low power consumption feature NDiS B426 supports display output by dual HDMI ports NDiS B426 is ideal as middle level digital signage player for a...

Страница 16: ...nterface Front 19V DC in 2x HDMI Ports 2x USB 3 0 1x RJ45 with LEDs 10 100 1000Mbps Ethernet 1x Power Switch with LED 1x DB9 for RS 232 1x Line out 1x Mic in Storage 1x 2 5 SATA HDD SSD Bay Expansion 1x NGFF M 2 E key for optional WLAN module Dimensions 269mm W x 147 4mm D x 29mm H w o mounting brackets Construction Top cover made by aluminum for main heat exchange Power Supply 1x External 63W AC ...

Страница 17: ...D HDMI Ports Used to connect an HDMI interface monitor USB 3 0 Ports Used to connect USB 3 0 2 0 1 1 devices LAN Used to connect the system to a local area network 19V DC Input Used to plug a DC power cord Line out Used to connect a headphone or a speaker Mic in Used to connect an external microphone COM Port The COM port supports RS232 compatible serial devices COM Power Switch LAN USB 3 0 Line o...

Страница 18: ...ter 1 Product Introduction Rear Panel Antenna Hole USB 2 0 USB 3 0 USB 2 0 Ports Used to connect USB 2 0 1 1 devices USB 3 0 Ports Used to connect USB 3 0 2 0 1 1 devices Antenna Holes for Optional Wi Fi The external antenna mounting holes are used to mount and connect optional Wi Fi antennas ...

Страница 19: ...ight 2016 NEXCOM International Co Ltd All Rights Reserved 5 NDiS B426 User Manual Chapter 1 Product Introduction Mechanical Dimensions 269 00 284 60 269 00 269 60 35 00 29 00 12 50 25 00 60 00 115 00 147 20 ...

Страница 20: ...before touching any internal components by touching a metal object Static electricity can damage many of the electronic components Humid environments tend to have less static electricity than dry environments A grounding strap is warranted whenever danger of static electricity exists Precautions Computer components and electronic circuit boards can be damaged by discharges of static electricity Wo...

Страница 21: ...e jumpers ensure that the jumper caps are placed on the correct pins When the jumper cap is placed on both pins the jumper is short If you remove the jumper cap or place the jumper cap on just one pin the jumper is open Refer to the illustrations below for examples of what the 2 pin and 3 pin jumpers look like when they are short on and open off Two Pin Jumpers Open Left and Short Right Three Pin ...

Страница 22: ...COM International Co Ltd All Rights Reserved 8 NDiS B426 User Manual Chapter 2 Jumpers and Connectors MJ2 J124 J138 J8 PJ1 J110 J87 J96 J95 XBT1 P110 P70 J13 J11 SW10 DIMM1 Location of the Jumpers and Connectors Top View ...

Страница 23: ...Copyright 2016 NEXCOM International Co Ltd All Rights Reserved 9 NDiS B426 User Manual Chapter 2 Jumpers and Connectors J63 Bottom View ...

Страница 24: ...tor J13 Dual USB 3 0 2 0 Connector P110 SATA HDD Connector J87 Microphone Input Connector J110 Audio Line out Connector PJ1 DC 19V Power in Connector J8 RJ45 Gigabit LAN Connector J138 Dual USB 3 0 Connector J124 HDMI 1 Connector MJ2 HDMI 2 Connector J63 NGFF M 2 Connector Connector Description P70 Power LED J95 COM1 Port Wafer J96 COM2 Port Wafer XBT1 RTC Battery Wafer Connector Button Table Head...

Страница 25: ...Setup Chapter 3 System Setup Installing a SATA HDD Prior to removing the chassis cover make sure the unit s power is off and disconnected from the power sources to prevent electric shock or system damage CAUTION CAUTION CAUTION 1 Remove the mounting screws around the chassis cover and then remove the cover ...

Страница 26: ...etup 2 Align the mounting holes that are on the sides of the SATA drive with the mounting holes on the drive bay and then use the provided mounting screws to secure the drive in place 3 Place the SATA drive in the chassis and connect the SATA data connector then use screws to secure the drive in the chassis ...

Страница 27: ...of the socket lock into position You will hear a distinctive click sound indicating the module is correctly locked into position 1 Insert the module into the socket at an approximately 30 degrees angle Apply firm even pressure to each end of the module until it slips into the socket The gold plated connector on the edge of the module will almost completely disappear inside the socket Memory module...

Страница 28: ...DiS B426 User Manual Chapter 3 System Setup 1 The NGFF M 2 Wi Fi module package includes the following items NGFF M 2 Wi Fi Module Antennas RF Cables Installing a NGFF M 2 Wi Fi Module Optional 2 Remove the cover on the bottom of the chassis to locate the NGFF M 2 slot ...

Страница 29: ...hapter 3 System Setup 4 Secure the module with mounting screws and attach one end of the RF cables onto the module 3 Insert the NGFF M 2 Wi Fi module into the NGFF M 2 slot at a 45 degrees angle until the gold plated connector on the edge of the module completely disappears inside the slot ...

Страница 30: ...hts Reserved 16 NDiS B426 User Manual Chapter 3 System Setup 5 Insert the antenna jack end of the cable through the antenna hole Antenna jack end of the cable 6 Insert ring 1 and ring 2 onto the antenna jack end of the cable Ring 1 Ring 2 Antenna jack ...

Страница 31: ...rackets 1 Align the mounting holes on the wall mount brackets to the mounting holes on both sides of the system then secure the brackets with screws 2 With the wall mount brackets secured place the system to the desired installation location and mount the system by fastening screws through the mounting holes on the brackets Mounting hole ...

Страница 32: ...er Manual Chapter 3 System Setup Installing the VESA Mount Kit 1 Align the mounting holes on the VESA mount kit to the VESA mounting holes on the back of the monitor then secure the VESA mount kit with screws 2 Secure the system to the VESA mount bracket with screws Mounting hole ...

Страница 33: ...m is configured with the values found in CMOS With easy to use pull down menus you can configure such items as Hard drives diskette drives and peripherals Video display type and display options Password protection from unauthorized use Power management features The settings made in the setup program affect how the computer performs It is important therefore first to try to understand all the setup...

Страница 34: ... be reported in one of two different ways If the error occurs before the display device is initialized a series of beeps will be transmitted If the error occurs after the display device is initialized the screen will display the error message Powering on the computer and immediately pressing Del allows you to enter Setup Press the key to enter Setup Legends Key Function Moves the highlight left or...

Страница 35: ...tup screen it indicates that there are more available fields not shown on the screen Use the up and down arrow keys to scroll through all the available fields Submenu When appears on the left of a particular field it indicates that a submenu which contains additional options are available for that field To display the submenu move the highlight to that field and press ...

Страница 36: ...l Help F7 Discard Changes F9 Optimized Defaults F10 Save Exit ESC Exit Set the Time Use Tab to switch between Time elements System Overview AMIEFI BIOS Version Build Date System Memory Size System Time System Date MAC Address Halt On SKLD4P1 NEXCOM 0303A 04 12 2016 4096 MB DDR4 18 45 57 Tue 04 26 2016 84 00 2D 20 7F D2 No Errors System Date The date format is day month date year Day displays a day...

Страница 37: ...Intel Intel R Celeron R CPU 3855U 1 60GHz Frequency 1 60 GHz Cache L1 32 KB x2 Cache L2 256 KB x2 Cache L3 2048 KB Ratio Actual Value 16 Virtualization Tech Disabled EIST tech Enabled Turbo Boost Tech Enabled CPU C6 report Enabled CPU C7 report Enabled Virtualization Tech When this field is set to Enabled the VMM can utilize the additional hardware capabilities provided by Vanderpool Technology EI...

Страница 38: ...torage devices SATA Controller Enables or disables the SATA controller SATA Mode Selection Configures the SATA as AHCI mode AHCI This option configures the Serial ATA drives to use AHCI Advanced Host Controller Interface AHCI allows the storage driver to enable the advanced Serial ATA features which will increase storage performance Advanced Version 2 17 1254 Copyright C 2016 American Megatrends I...

Страница 39: ... Fan fault Hardware Health Configuration CPU Fan Fail Warning Disabled CPU Q FAN Control Disabled CPU Temperature 35 C Tcontrol Offset 85 C CPU Fan Speed 5113 RPM VCore Voltage 1 188 V 3 3V Voltage 3 309 V 5V Voltage 5 044 V 12V Voltage 12 230 V CPU Fan Fail Warning Enables or disables detection of fan failure CPU Q FAN Control Enables or disables control of CPU fan speed CPU Temperature Detects a...

Страница 40: ...board VGA Config Onboard Audio Onboard LAN Device LAN Boot ROM Serial Port 1 Configuration Device Settings Change Settings Serial Port 2 Configuration Device Settings HD Audio Enabled Enabled Enabled IO 3F8h IRQ 4 Auto Disabled Reset Required Onboard Device Settings This section is used to configure the onboard devices Onboard VGA Config Configuration for onboard VGA devices Onboard Audio Enables ...

Страница 41: ...6 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F7 Discard Changes F9 Optimized Defaults F10 Save Exit ESC Exit Enables or Disables BIOS support for security device O S will not show Security Device TCG EFI protocol and INT1A interface will not be available Trusted Computing Settings TPM Supported Disabled Onboard VGA Config This section is used to confi...

Страница 42: ...gure Intel Management Engine Intel ME Power This section is used to configure the power management features APM Configuration Configuration for Advanced Power Management EUP Enables the system to shut down to the lowest possible power state by removing all power to the system board The wake up function will be lost if EUP is enabled Save Exit Advanced Power Security Boot Main Version 2 17 1254 Cop...

Страница 43: ... to wake up on LAN Power on RTC Alarm Enables or disables the system to wake up on RTC alarm When enabled the system will wake on the hr min sec specified RTC Alarm Date Hour Minute and Second Configures the date and time of the RTC alarm AC Power Loss Power Off When power returns after an AC power failure the system s power is off You must press the power button to power on the system Power On Wh...

Страница 44: ...Secure Boot Secure Boot only works when the system runs in user mode Secure Boot Mode Select this to configure the Secure Boot mode Standard Fixed secure boot policy Custom Changeable Image Execution policy and Secure Boot key databases Boot Launch CSM This option controls if CSM will be launched Boot Option Filter Configures which devices the system will boot from Network Drives Sets the order of...

Страница 45: ...ecurity Boot Main Version 2 17 1254 Copyright C 2016 American Megatrends Inc Aptio Setup Utility Copyright C 2016 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F7 Discard Changes F9 Optimized Defaults F10 Save Exit ESC Exit Enable or Disable Full Screen Logo Boot Settings Configuration Full Screen Logo Bootup Num Lock Keyboard Error Message Display Fast ...

Страница 46: ...elect this field then press Enter A dialog box will appear Confirm by selecting Yes You can also press F4 to save and exit Setup Discard Changes and Exit To exit the Setup utility without saving the changes select this field then press Enter You may be prompted to confirm again before exiting You can also press ESC to exit without saving the changes Load Optimal Defaults To restore the BIOS to def...

Страница 47: ...ed 0 WDT Status 1 WDT value is equal to 0 0 WDT value is not equal to 0 SMI Control Register 2 Index F1h Default 00h Bit Description 7 Reserved 6 0 Edge trigger 1 Level trigger 5 3 Reserved 2 This bit is to enable the generation of a SMI due to WDT s IRQ EN_WDT 1 This bit is to enable the generation of a SMI due to CIR s IRQ EN_CIR 0 This bit is to enable the generation of a SMI due to PBD s IRQ E...

Страница 48: ... 1 62 5ms x WDT Timer out value default 3 5s 0 Determined by WDT Time out value select 1 bit 7 of this register 4 WDT Output through PWRGD Enable 1 Enable 0 Disable During LRESET this bit is selected by JP2 power on strapping option 3 0 Interrupt Level Select for WDT Please refer to Interrupt Level Mapping Table Watchdog Timer Time out Value LSB Register Index 73h Default 38h Bit Description 7 0 W...