
Page | 17
Chapter 3
SETTING UP
This chapter explains how to connect power, monitors and audio visual sources, and
external control devices to your NewTek TriCaster
®
system. It also reviews the
registration process. After completing this short section, you’ll be all set to begin using
TriCaster.
To begin, let’s review ‘what came in the box’:
NewTek TriCaster
®
Keys to front panel of case (Rack-mount models)
Four attachable rubber feet (for desktop use)
A/C power cabling (external PSU with cable for TriCaster Mini™)
BNC removal tool (to assist with cable connection and removal, rack-mount units only)
NewTek mouse and keyboard
Quick Start Guide
NewTek 3PLAY™ brochure
NewTek TriCaster registration reminder card
New product letter
SECTION 3.1
COMMAND AND CONTROL
Hint: TriCaster’s interface requires a monitor resolution setting
of at least 1600x1050. 4RU systems may require 1920x1080.
1.
Connect an external computer monitor to the port
labeled Interface on the backplate of 4RU models.
2.
For 2RU models, use the DVI connector nearest to the
Video In group for the interface monitor connection. For
TriCaster Mini SDI or Mini, use either port in the group
labeled Interface/Multiview.
3.
Connect the mouse and keyboard to USB ports on
TriCaster.
4.
Connect the power cord (or cords, for 4RU models); or,
for TriCaster Mini or Mini SDI, the external power
supply between the DC Power input connection on
TriCaster’s backplate and an external power receptacle.
5.
Turn on the computer monitor.
6.
Press the Power switch on TriCaster’s faceplate (located behind the door
on some models).
At this point, the blue Power LED will illuminate, and the adjacent hard drive activity light should flicker as
the device boots up. (If this does not happen, check your connections and retry).
A word about UPS devices:
‘Modified sine wave’ UPS devices are
popular due to low manufacturing
costs. However, such units should
generally be viewed as being of low
quality and possibly inadequate to
fully protect the system from
abnormal power events.
For a modest added cost, consider a
"pure sine wave" UPS. These units can
be relied on to supply very clean
power, eliminating potential
problems, and are recommended for
applications demanding high
reliability.
Содержание tricaster advanced edition
Страница 1: ......
Страница 16: ......
Страница 18: ......
Страница 20: ......
Страница 36: ...Page 20 FIGURE 3 1 4RU MODELS FIGURE 3 2 TRICASTER 460 FIGURE 3 3 TRICASTER 410...
Страница 56: ......
Страница 60: ......
Страница 62: ......
Страница 76: ......
Страница 82: ......
Страница 86: ......
Страница 110: ......
Страница 152: ......
Страница 158: ...Page 142...
Страница 204: ......
Страница 212: ......
Страница 218: ......
Страница 222: ......
Страница 280: ......
Страница 312: ......
Страница 320: ......
Страница 324: ......
Страница 330: ...Page 314 FIGURE 21 91...
Страница 332: ......
Страница 339: ......