PLATINUM Series Controllers User’s Guide
44
Reference Section: Programming Mode (PRoG)
7.
Reference Section: Programming Mode (PRoG)
Use Programming Mode to set the following parameters and perform the following functions:
7.
Reference Section: Programming Mode (PRoG) ................................................................................ 44
7.1
Setpoint 1 Configuration (PRoG > SP1) ....................................................................................... 44
7.2
Setpoint 2 Configuration (PRoG > SP2) ....................................................................................... 44
7.3
Alarm Mode Configuration (PRoG > ALM.1, ALM.2)................................................................... 45
7.4
Output Channel 1–6 Configuration (PRoG > oUt.1–oUt.6) ......................................................... 49
7.5
PID Configuration (PRoG > PId.S) ................................................................................................ 53
7.6
Remote Setpoint Configuration (PRoG > RM.SP) ........................................................................ 55
7.7
Multi-Ramp/Soak Mode Parameters (PRoG > M.RMP) .............................................................. 57
7.1
Setpoint 1 Configuration (PRoG > SP1)
Select the Setpoint 1 (SP1) parameter.
Set the process goal value for PId or oN.oF control.
Confirm the value.
7.2
Setpoint 2 Configuration (PRoG > SP2)
Select the Setpoint 2 (SP2) parameter. SP2 is used with Alarm functions and with on/off
control when setting up for Heat/Cool Control Mode.
Navigate to the desired setting. Settings include the following:
ASbo – The value for SP2 is specified in Absolute Mode (factory default)
dEVI – The value specified for SP2 indicates an offset (positive or negative) from
SP1; this allows SP2 to track any changes to SP1 automatically
Select the indicated setting.
Set the correct value.
Confirm the value.