Страница 1: ...Compact High Speed Rotation Stages PR50 Series USER S MANUAL G U ARANTE E D S P E CIFICATIO N S...
Страница 2: ...ther warranties expressed or implied including any implied warranty of merchantability or fitness for a particular use Newport Corporation shall not be liable for any indirect special or consequential...
Страница 3: ...ical Specifications 4 3 3 Load Specification Definitions 4 3 4 Load Characteristics and Stiffness 4 3 5 Stage Weights 5 4 0 Drives and Motors 5 4 1 Stepper Drive Version 5 4 2 DC Motor Drive Version 6...
Страница 4: ...EDH0176En1051 12 18 iv PR50 Series Compact High Speed Rotation Stages 9 0 Maintenance 14 9 1 Maintenance 14 9 2 Repair 14 9 3 Calibration 14 Service Form 15...
Страница 5: ...ns of the Directive 2006 42 EC on machinery complies with all the relevant provisions of the Directive 2014 30 EU relating to electro magnetic compatibility complies with all the relevant provisions o...
Страница 6: ...ty safety and preservation of the equipment or important tips WARNING Warning indicates a potentially dangerous situation which can result in bodily harm or death CAUTION Caution indicates a potential...
Страница 7: ...if any liquid has entered the stage switch off the motor power and then disconnect the electronics from power supply Contact your Newport service facility and request repairs WARNING Do not insert or...
Страница 8: ...es This may cause an electric shock Operating temperature 10 to 35 C Storage temperature 10 to 40 C in its original packaging CAUTION Do not move this stage if its motor power is on Make sure that the...
Страница 9: ...tion stage that you have purchased in the PR50 Series REMARK Due to its very low profile the PR50 stage contains pressure sensitive components For usage at a pressure level below 0 25 bar PR50 rotatio...
Страница 10: ...rnative to the SR50 for applications that do not require the high resolution and precision of the SR50 or for applications that could benefit from higher speeds up to 20 s The stages feature angular r...
Страница 11: ...Absolute Accuracy Accuracy Correction Factor x Travel Repeatability Ability of a system to achieve a commanded position over many attempts Reversal Value Hysteresis Difference between actual position...
Страница 12: ...CATIO N S Travel Range 360 continuous Minimum Incremental Motion 0 02 Uni directional Repeatability Typical 0 005 Bidirectional Repeatability Typical 1 0 030 Absolute Typical 1 0 025 Maximum Speed 2 s...
Страница 13: ...ep drive version PR50PP Half Step Drive Is used for stepper motors when 1 pulse emitted by electronic corresponds to theoretical physical motion of 1 2 of a full step of the motor Stepper Motor Perfor...
Страница 14: ...otors In the above drawings Motor signal is referred to Motor signal When the stage moves in Direction the Motor voltage is higher than Motor voltage When the stage moves in Direction the Motor voltag...
Страница 15: ...to pins 19 20 23 and 24 of the SUB D25 connector Encoder are differential pair type RS 422 type output signals Using these signals permits a high immunity to noise Emission circuits generally used by...
Страница 16: ...11 N C 12 N C 13 Mechanical Zero 14 Ground 15 N C 16 0 V 17 Do not connect 18 Do not connect 19 Encoder Phase A 20 Encoder Phase B 21 5 V 22 0 V 23 Encoder Phase A 24 Encoder Phase B 25 N C PR50PP 1...
Страница 17: ...lean the electronics unit CAUTION To protect the unit from damage be sure to Keep all air vents free of dirt and dust Keep all liquids away from the unit Do not expose the unit to excessive moisture 8...
Страница 18: ...elivered with a 3 meter cable This cable is equipped with a SUB D25M connector for direct connection to Newport Controllers BENDING STATIC CABLE 94 24 CABLE IN MOTION 2 76 70 24 6 LOCKING KNOBS 2 28 5...
Страница 19: ...ce from other electrical cables in your environment to avoid potential cross talk For cable lengths in excess of 3 meters we recommend the MMCABLE REG to ensure a high quality regulated 5 V supply to...
Страница 20: ...th non Newport controllers WARNING Newport guarantees compliance of PR50 stages only if used with Newport cables and controllers It is the customer s responsibility to modify the cable and take care o...
Страница 21: ...NGS 4 65 118 1 97 50 39 10 063 1 6 39 10 83 21 2 HOLES M3 THD DEPTH 24 6 HOLE 8 32 THD DEPTH 18 4 5 83 21 2 RETAINING RINGS THICKNESS 26 6 5 2 28 58 1 97 50 4 HOLES M3 THD ON SQR 98 25 DEPTH 12 3 SUB...
Страница 22: ...for re lubrication after 2000 hours of use If the PR50 rotation stage is mounted on a workstation and cannot be easily removed please contact Newport s After Sales Service for further instructions 9...
Страница 23: ...Fax Name Company Address Country P O Number Item s Being Returned Model Description Reasons of return of goods please list any specific problems Return authorization Please obtain prior to return of i...
Страница 24: ...sales newport com Technical Support Tel 800 222 6440 e mail tech newport com Service RMAs Returns Tel 800 222 6440 e mail service newport com Europe MICRO CONTROLE Spectra Physics S A S 9 rue du Bois...