Newport IsoStation Скачать руководство пользователя страница 1

IsoStation

Vibration 

Isolated Workstation

I

NSTRUCTION

M

ANUAL

Содержание IsoStation

Страница 1: ...IsoStation Vibration Isolated Workstation INSTRUCTION MANUAL...

Страница 2: ...Newport representative or contact Newport headquarters in Irvine California You will be given prompt assistance and return instructions Repaired or replaced products are warranted for the balance of...

Страница 3: ...ystem Assembly 5 2 1 3 Installing the Table Top 6 2 2 Squaring and Leveling the Frame 6 2 3 Isolating the Table Top 7 2 4 Installing Accessories 10 Section 3 Operation 3 1 Principles of Operation 15 3...

Страница 4: ...tment 4 2 2 Caster Installation 5 2 3 Air Regulator Filter ARF 6 2 4 Air System Diagram 7 2 5 Leveling Arm Orientation 7 2 6 Leveling Valve 8 2 7 Installing Isolator Modules 9 2 8 Workstation Diagram...

Страница 5: ...th optional casters the system is easy to move without heavy equipment and may be safely lifted by building elevators It is possible to tailor the system to a wide variety of applications using the ra...

Страница 6: ...eforsecureattachment for virtually any type of spe cial equipment A generous array of tapped holes on the top and side surfaces per mits secure mounting Many customers order an extra mount for last mi...

Страница 7: ...oid locations adjacent to major sources of floor vibration such as operating machinery WARNING If installation site is susceptible to earthquakes it is recommended that the legs be securely fastened t...

Страница 8: ...om of the frame Jam nut Height adjust nut 2 00 50mm Figure 2 1 Leveling Pad Adjustment C If casters have been ordered fasten them to the frame assemblies at the pre drilled and tapped locations on the...

Страница 9: ...loose 2 1 2 Air System Assembly The IsoStation workstation is shipped with the air regulator filter ARF Figure 2 3 and leveling valves installed on the leg assemblies A Using the white tubing provide...

Страница 10: ...ling pads Figure 2 1 until the table top contacts evenly on all four of the legs and does not rock when pressed down on at any of the four corners B Tighten all frame and armrest support bolts C Level...

Страница 11: ...ble top Figure 2 5 Adjustment screw Approximately 1 8 3mm Isolator Pad Table top Figure 2 5 Leveling Arm Orientation B Fully close turn clockwise the needle valves located on the leveling valves Figur...

Страница 12: ...the system is stable or close the needle valves slightly E Lift and press down each corner of the table top to ensure that the approximate 1 8 inch 3 mm of desired vertical travel exists Push the top...

Страница 13: ...EWS LOCK HORIZONTAL MOTION TWO SCREWS SECURE ISOLATOR MODULE TO EACH LEG WHITE TUBE CONNECTOR FLANGE FLUSH WITH INSIDE OF LEG GREY PIGTAIL TUBE FACE IN TOWARD CENTER OF FRAME Figure 2 7 Installing Iso...

Страница 14: ...nables the support ring to be mounted at the level of 1 2 or 4 thick work surfaces Use the following list to determine which of the five threaded holes to use 4 thick work surface Install the bolts fi...

Страница 15: ...ing tubes P N 3847 BA 252 Cup pt set screw P N 20389 01 Washer neoprene P N 3664 BA 244 Screw button HD P N 20308 Support arm bracket P N 3941 JO 0905 060 Flat washer P N 3751 AF 248 Hex head screw P...

Страница 16: ...ort arm brackets with the threaded holes facing down and install a 1 inch long hex bolt P N 3751 AF 248 through the bracket and into each endpiece Tighten the four bolts that connect the bracket and t...

Страница 17: ...ors Feed the white tubing located between the control valve and the isolator through the hole in the leg and up over the edge of the leg Insert the fitting on the 1 8 inch pigtail tube on the bottom o...

Страница 18: ...isolation problems see Section 4 Trouble shooting Static Dissipative Table Tops Figure 2 9 indicates how to attach the special ground strap hardware to your IsoStation if it has come with the static...

Страница 19: ...ke minor performance adjustments to the isolation system to suit the individual users needs This involves adjustments to the system air pres sure leveling arms and needle valves A Stabilizing high cen...

Страница 20: ...usehold cleaner such as 409 or Fantastic on a clean cloth and wipe down Avoid using abrasive cleaners since they will foul the mounting holes and also damage the laminate tops Isolated mass work surfa...

Страница 21: ...eveling valves Turn them counterclockwise 1 8 turn if they appear to be closed 4 1 2 Other Causes of Poor Isolation A Vibration may be transmitted to the table due to direct physical contact of equipm...

Страница 22: ...rder number 3 Complete description of the problem If components are to be returned to Newport Corporation you will be given a Return Number which you should reference in your shipping documents Please...

Страница 23: ...____________________________________________________________________________________________________________________ ___________________________________________________________________________________...

Страница 24: ...20...

Страница 25: ...21...

Страница 26: ...ied compliant with ISO 9001 by the British Standards Institution Certificate No FM 27207 R E G I ST ERED F I R M Visit Newport Online at www newport com Newport Corporation Worldwide Headquarters 1791...

Отзывы: