BQ
enable DIO bits for jog mode
IMM PGM MIP
USAGE
♦
♦
♦
SYNTAX
xxBQ
nn or
BQ
?
PARAMETERS
Description
xx
[ int ]
-
axis number
nn
[ int ]
-
disable or enable
Range
xx
-
1
to
MAX AXES
nn
-
0 =
disable, and
1 =
enable
Units
xx
-
none
nn
-
one
Defaults xx
missing:
error 37, AXIS NUMBER MISSING
out of range:
error 9, AXIS NUMBER OUT OF RANGE
nn
missing:
error 38, COMMAND PARAMETER MISSING
out of range:
error xx2, PARAMETER OUT OF RANGE
DESCRIPTION
This command is used to disable or enable jogging of a requested axis through
DIO bits.
RETURNS
If “?” sign is issued along with command, the controller returns the status of jog
through DIO bits.
REL. COMMANDS
BP
-
assign DIO bits for jog mode
EXAMPLE
1BP3,4
|
set DIO bit #3 to jog axis #1 in negative direction and
|
DIO bit #4 to jog axis #1 in positive direction
1BP?
|
query the DIO bits assigned for jogging
3,4
|
controller returns the bit assignment
1BQ1
|
enable axis #1 jogging through DIO bits.