Страница 2: ...Electronics Inc accepts no liability for any errors it contains and reserves the right to alter specifications without notice WARNING These products are not designed for use in and should not be used...
Страница 3: ...tion 3 Getting Started 5 3 1 Main Board Power Jumpers 5 3 2 Converting F to C vice versa 7 3 3 Installation and Panel Mounting 8 3 4 Sensor Input Connections 10 3 5 Analog Output Connections 12 3 6 Di...
Страница 4: ...us However due to the internal design of the meter the input type and resolution CANNOT be changed on any J K T or E unit The meter is available in many different styles All of the Thermocouple models...
Страница 5: ...iscussed in this operator s manual MODEL TYPE C or F RESOLUTION 205 JF1 J F 1 0 F 205 JF2 J F 0 1 F 205 JC1 J C 1 0 C 205 JC2 J C 0 1 C 205 KF1 K F 1 0 F 205 KF2 K F 0 1 F 205 KC1 K C 1 0 C 205 KC2 K...
Страница 6: ...26 Vdc 110mA max non isolated Use ungrounded Thermocouples to avoid ground loops 205 TC type C5 100 Vac 15 50 60 Hz 205 TC type C8 24 Vac 15 50 60 Hz The following 3 1 2 digit mini RTD panel meters ar...
Страница 7: ...ides you with information that is important to successfully setup and use the Programmable Digital Meter CAUTION or WARNING tells you about the risk of electric shock CAUTION WARNING or IMPORTANT tell...
Страница 8: ......
Страница 9: ...any signs of damage Take particular note of any evidence of rough handling in transit Immediately report any damage to the shipping agent The carrier will not honor any claims unless all shipping mate...
Страница 10: ...incorporated in the mains supply cord Furthermore to provide protection against excessive energy being drawn from the mains supply in case of a fault in the equipment an overcurrent protection device...
Страница 11: ...hows the panel thermometer Figure 2 1 Panel Thermometer Features Display 3 1 2 Digit 7 Segment Red or Green LED Full size 14 2 mm 0 56 LED Display Analog Output Standard 3 64 DIN Standard Panel Cutout...
Страница 12: ...Connector Description For wire colors refer to Table 3 1 Connector Description Connector PIN AC Earth Ground P1 1 AC Neutral P1 2 AC Line P1 3 DC DC Return P1 1 DC DC P1 2 DC No Connection Not used P1...
Страница 13: ...ion so all you need to do is to select the jumpers as described in this section Important These changes must be performed by a qualified technician To change the Factory preset jumpers do the followin...
Страница 14: ...e 3 1 shows the location of solder jumpers W1 through W3 Figure 3 1 PC Board Jumper Locations S3 P3 P1 W1 W2 W3 2 1 2 3 1 TRANSFORMER SPAN DISPLAY ZERO COMPONENT SIDE P2 2 3 1 AC VOLTAGE INSTALL REMOV...
Страница 15: ...nit from the panel if installed 2 Remove the printed circuit board from the case as described in Section 3 8 3 Follow the instructions to convert to Celsius The unit will display degrees Celsius when...
Страница 16: ...ver into the rounded corner of the lens and lift out 2 Remove the two mounting screws from both sides of the display Pry both sides of the mounting clamp out and down to remove it from the meter case...
Страница 17: ...PANEL CUTOUT PANEL CUTOUT CASE 0 25 6 4 MAX 0 03 0 8 MIN PANEL THICKNESS 0 874 012 000 22 20 0 30 0 00 R 0 06 1 5 4 PLCS 68 00 0 70 0 00 2 677 0 028 000 MOUNTING SCREW HOLES MOUNTING SCREW 2 MOUNTING...
Страница 18: ...would have a TF2 in the part number The 1 at the end of the part number indicates a 1 degree resolution and 2 at the end of the part number indicates a 0 1 degree resolution See Table 1 1 for model nu...
Страница 19: ...or that is supplied with the unit Refer to Figure 3 4 for wiring instructions and Table 2 1 for wire colors Plug the female connector into the P3 male connector at the rear of the meter Figure 2 2 sho...
Страница 20: ...d that an ungrounded thermocouple probe be used to prevent ground loop problems To access the analog signal attach copper wire to the 3 pin female connector that is supplied with the meter Refer to Fi...
Страница 21: ...te itself 2 5 times per second To access the Display Hold function attach copper wire to the 3 pin female connector that is supplied with the meter Refer to Figure 3 6 for wiring instructions This con...
Страница 22: ...power specified by the customer at the time of ordering The voltage is printed on the Label under Input power Refer to Section 3 2 to convert from one configuration to another To connect power to the...
Страница 23: ...orange 3 pin female connector that is supplied with the meter Refer to Figure 3 8 for wiring instructions Plug the female connector into the orange P1 male connector at the rear of the meter Figure 2...
Страница 24: ...the back of the meter Grasp them firmly on the top and bottom of the connector and pull Figure 3 9 shows the location of the three connectors 3 Remove the lens mounting screws and mounting clamp from...
Страница 25: ...the components showing soldered side down in the right hand 3 Slip the component board into the case and slide in as far as it will go You will also have to release the tab at the rear on the other si...
Страница 26: ...r and the display will show the temperature of the probe The meter is shipped from the factory calibrated to the accuracy as specified No re calibration is necessary In the event that there is a desir...
Страница 27: ...OCEDURE Refer to Section 4 2 1 for details on how to calibrate the meter using the Thermocouple Calibrator Refer to Section 4 2 2 for details on how to calibrate the meter using the Millivolt Source 4...
Страница 28: ...o connector P3 Pin 2 Be sure to observe polarity and use the correct thermocouple wire Type J wire for Type J meter Figure 4 2 Calibration a Thermocouple Calibrate 3 Connect the power to the meter All...
Страница 29: ...2 in the model number set the calibrator for 0 0 C and the unit display should show 0 2 C 5 Adjust the thermocouple calibrator to output the temperature shown in the second line of column 2 Check to s...
Страница 30: ...L T C CALIBRATOR METER POT TO OPTION DISPLAY DISPLAY ADJUST JF1 32 F 32 F Zero 1346 F 1346 F Span JF2 32 0 F 31 6 F Zero 167 0 F 167 0 F Span JC1 0 C 0 C Zero 730 C 730 C Span JC2 0 0 C 0 2 C Zero 170...
Страница 31: ...ete models preface section MODEL T C CALIBRATOR METER POT TO OPTION DISPLAY ADJUST DISPLAY TF1 32 F 31 F Zero 716 F 716 F Span TF2 32 0 F 32 0 F Zero 185 0 F 185 0 F Span TC1 0 C 0 C Zero 380 C 380 C...
Страница 32: ...ce to the MCJ Electronic Ice Point or ice bath which in turn connects to the thermocouple input connector P3 as shown in Figure 4 3 Connect the negative red thermocouple wire to connector P3 Pin 1 Con...
Страница 33: ...t the zero potentiometer until it reads that simulated value For example if the meter has a JC2 in the model number set the millivolt source for 0 0 and the meter display should show 0 C 5 Adjust the...
Страница 34: ...VOLT MODEL VALUE FROM METER POT TO OPTION MILLIVOLT DISPLAY ADJUST SOURCE JF1 0 0 32 F Zero 41 013 1346 F Span JF2 0 0 31 6 F Zero 3 917 167 0 F Span JC1 0 0 0 C Zero 41 013 730 C Span JC2 0 0 0 2 C Z...
Страница 35: ...te models preface section MILLIVOLT MODEL VALUE FROM METER POT TO OPTION MILLIVOLT DISPLAY ADJUST SOURCE TF1 0 0 31 F Zero 19 638 716 F Span TF2 0 0 32 0 F Zero 3 584 185 0 F Span TC1 0 0 0 C Zero 19...
Страница 36: ...70 dB 50 60 Hz CMR Analog RTN to PWR GND 120 dB DC to 60 Hz CMV Analog RTN to PWR GND Dielectric strength to 1500 V transient per 260 Volt rms or DC working voltage ACCURACY at 25 C Range for rated ac...
Страница 37: ...he Bezel 4 72 120 mm w connectors Panel Cutout 0 87 H x 2 68 W 22 2 x 68 mm Weight 7 ounces 200 grams Panel Thickness minimum 0 03 0 76mm maximum 0 25 6 25mm Case Material 94V 1 UL rated thermoplastic...
Страница 38: ...80 2 661 67 60 4 60 116 8 4 134 105 00 0 197 5 00 0 945 24 00 2 835 72 00 PANEL CUTOUT 0 25 6 4 MAX 0 03 0 8 MIN PANEL THICKNESS 0 874 012 000 22 20 0 30 0 00 R 0 06 1 5 4 PLCS 68 00 0 70 0 00 2 677 0...
Страница 39: ...C 1 0 C JC2 1 0 C 199 9 to 199 9 C 0 1 C KF1 2 7 F 157 to 1999 F 1 0 F KF2 1 8 F 199 9 to 199 9 F 0 1 F KC1 1 5 C 105 to 1372 C 1 0 C KC2 1 0 C 199 9 to 199 9 C 0 1 C TF1 2 7 F 157 to 752 F 1 0 F TF2...
Страница 40: ...ires of a two wire or differential input NORMAL MODE REJECTION NMR a measure of the rejection of unwanted signal due to a voltage applied between the wires of a two wire or differential input shown as...
Страница 41: ...rwise shall not exceed the purchase price of the component upon which liability is based In no event shall NEWPORT be liable for consequential incidental or special damages CONDITIONS Equipment sold b...
Страница 42: ...488 www newportuk co uk e mail sales newportuk co uk Newport Electronics B V Postbus 8034 1180 LA Amstelveen The Netherlands TEL 31 20 3472121 FAX 31 20 6434643 Toll Free 0800 0993344 www newport nl...