IMPORTANT NOTICE

All wiring should be carried out by a competent person or a qualified electrician and should be fitted to IEE 17th Edition Wiring regulations

BS7671:2008. The circuit should be isolated before carrying out any work. Failure to adhere to the instructions will invalidate the warranty.

Instructions

Newlec Helpline: 0800 783 6909

RPM 491

PRODUCT RANGE

NEWLEC DALI OCCUPANCY DETECTOR

PART NUMBER

NL5701DALI

FEATURES

  Presence and Absence Detection Options

  Automatic Daylight Harvesting

  Settable Timing Modes

  Basic Luminaire setup without expensive commissioning    

        tools

  Broadcast and Group Functions

  Dual Mode Remote Control

  Room & Corridor Options

  Manual Lux Level and Sensitivity Control

  Coloured Feedback LEDs

  Walk Test

  Can control LED and fluorescent DALI luminaires 

A

Absence Control Lines

A

Absence Control Lines

DA

DALI Bus line

DA

DALI Bus line

NEWLEC DALI OCCUPANCY DETECTOR WIRING CONNECTIONS

NEWLEC DALI OCCUPANCY DETECTOR INSTRUCTIONS MUST BE READ IN CONJUNCTION WITH REMOTE CONTROL IN-

STRUCTIONS IN ORDER TO ENABLE ALL FEATURES OF THE OCCUPANCY DETECTOR

This flush mounted ceiling mount Newlec DALI Occupancy Detector has full DALI flexibility and is the intelligent sensor element of 
the Newlec DALI network system. It can automatically address the lighting ballasts without the need for expensive controllers. The 
Occupancy Detector is switched on by the detection of moving body heat within a specified range. When this moving body heat is no 
longer detected the unit will dim down the luminaires and eventually switch off. It will also automatically harvest available daylight to 
maximise energy savings. With the remote it is possible to set dimming time delays and Room and Corridor options. There are also 
helpful coloured feedback LEDs to make programming easier. 

MAINS POWER SHOULD NEVER BE CONNECTED TO ANY TERMINAL OF THE DALI OCCUPANCY DETECTOR

The DALI connections are made to the DA DA bus lines. There is no polarity but it is advisable and good practice to keep wiring 
colours to the same connections for consistency. 
Absence detection on the Newlec DALI network system can easily be achieved with the addition of a standard 1 gang 1 way switch. If 
2 way and intermediate switches are required these can also be connected in to the terminals. To turn this DALI Occupancy Detector 
from a presence detector to an absence detector simply connect an ordinary on/off switch to the A and A Absence Control lines and 
the Occupancy Detector can be switched between presence and absence mode as desired. 

CAREFUL POSITIONING OF THE OCCUPANCY DETECTOR IS ESSENTIAL TO MAINTAIN OPTIMUM DETECTION PERFORMANCE.

Occupancy Detector detection pattern

2.4 METRES

  

Instruction  Data  

374-­‐CMPIRDALI  

Elkay  easyDALi  PIR  

18v  d.c.  250ma  for  use  with  Power  Supply  Unit  
(374-­‐PSU)  

  
  

Features  

Presence  and  Absence  Detection  Options  
Automatic  Daylight  Harvesting  
Settable  Timing  Modes  
Basic  Luminaire  setup  without  expensive  commissioning  tools  
Broadcast  and  Group  Functions  
Remote  Control  
Room  &  Corridor  Options  
Manual  Lux  Level    and  Sensitivity  Control  
Coloured  Feedback  LEDs  
Dual  Mode  Walk  Test  
Can  control  LED  and  fluorescent  DALI  luminaires    
  

Elkay  easyDALi  PIR  Instructions  must  be  read  in  conjunction  
with  Remote  Control  Instructions  in  order  to  enable  all  
features  of  the  PIR.  

  
  

  

  
  
  
  

  
  
This  flush  mounted  ceiling  mount  Elkay  easyDALi  PIR  has  full  DALI  
flexibility  and  is  the  intelligent  sensor  element  of  the  Elkay  easyDALI  
system.  It  can  automatically  address  the  lighting  ballasts  without  the  
need  for  expensive  controllers.  The  PIR  is  switched  on  by  the  
detection  of  moving  infra-­‐red  heat  within  a  specified  range.  When  
this  moving  infra-­‐red  heat  is  no  longer  detected  the  unit  will  dim  
down  the  load  and  eventually  switch  off.  It  will  also  automatically  
harvest  available  daylight  to  maximise  energy  savings.  
With  the  remote  it  is  possible  to  set  dimming  time  delays  and  Room  
and  Corridor  options.  There  are  also  helpful  coloured  feedback  LEDs  
to  make  programming  easier.    
  

  

  

Elkay  easyDALI  PIR  wiring  connections  
  

A  

Absence  Control  Lines  

A  

Absence  Control  Lines  

DA  

DALI  Bus  line  

DA  

DALI  Bus  line  

Mains  power  should  never  be  connected  to  any  terminal  of  
the  easyDALi  PIR.  

  
  
  
  
  
  
  
  

The  DALI  connections  are  made  into  DA  DA  bus  lines.  There  is  
no  polarity  but  it  is  advisable  and  good  practice  to  keep  
wiring  colours  to  the  same  connections  for  consistency.    
To  turn  this  easyDALi  PIR  from  a  Presence  detector  to  an  
absence  detector  simply  connect  an  ordinary  on/off  switch  to  
the  A  and  A  Absence  Control  lines  and  the  PIR  will  know  
automatically  that  it  is  in  Absence  mode.  

  

Absence  detection  on  the  Elkay  easy  DALI  system  can  easily  
be  achieved  with  the  addition  of  a  standard  1  gang  1  way  
switch.  If  2  way  and  intermediate  switches  are  required  these  
can  also  be  connected  in  to  the  terminals.  

  
CAREFUL  POSITIONING  OF  THE  PIR  IS  ESSENTIAL  TO  
MAINTAIN  OPTIMUM  DETECTION  PERFORMANCE.  
  

  

  

  

  

  

  

d

A    A    DA    DA  

Отзывы: