20
nlscan.com
RF 433MHz communication setting for Handheld unit (Continued)
Enter sleeping mode interval: If it is enabled, the handheld unit will enter sleeping mode while no
operation beyond the time interval defined; the handheld unit will return to normal mode by pulling the
scanner trigger.
SETUP
Option barcode
Option
Alpha. entry
Handheld unit RF channel No.
01-08
01-08
06*
Handheld unit ID
01-16
01-16
01*
RF power level
10dbm
7dbm
5dbm
0dbm
-5dbm
-10dbm
-15dbm
01*
02
03
04
05
06
07
Frequency hopping
Disable
Enable
00
01*
RF operating mode
Normal
Out-of-range batch
Standard batch
00*
01
02
Beep on reconnect attempt
Disable
Enable
00*
01
Radio connection checking interval
00-ffH (second)
00-ffH
03*
Save data at low-battery or power-off
Disable
Enable
00*
01
Low battery indicator
Disable
Enable
00
01*
Enter sleeping mode interval
00-ffH (minute)
00-ffH
0F*
END
Enter batch mode
Send batch data
Show channel information of handheld unit