background image

 

iii

IMPORTANT INFORMATION

 

Read prior to activation. 

You have purchased a sophisticated electronic device.  To 
operate it properly, please read this manual carefully. 

Ignoring operation procedures described in this manual will 

void your warranty. 

 

 

NEVER 

disassemble the unit. This device contains a source 

of high voltage, which may be hazardous to your health. 

 

NEVER 

expose objective lens of an active unit to bright 

light, including daylight. In the daytime objective lens must 
be covered by cap. A tiny hole in lens cap provides enough 
light for daytime testing.   

 

NEVER 

aim an active unit at intense light sources, such as 

lights, headlamps, campfires, the Moon, etc. 

 

NEVER 

reverse the polarity of a battery. 

 

NEVER 

connect the unit to the external power supplies.

 

 

ALWAYS 

remove battery when not in use for a long period. 

 

ALWAYS 

keep the objective lenses covered when not in use

 

ALWAYS 

store the unit in a warm dry place.

 

Содержание NV207-G2

Страница 1: ...Operation Manual NIGHT VISION MONOCULAR GOGGLES NV207 G2 105 Sparks Ave Toronto ON M2H 2S5 Canada ...

Страница 2: ...ii ...

Страница 3: ...th NEVER expose objective lens of an active unit to bright light including daylight In the daytime objective lens must be covered by cap A tiny hole in lens cap provides enough light for daytime testing NEVER aim an active unit at intense light sources such as lights headlamps campfires the Moon etc NEVER reverse the polarity of a battery NEVER connect the unit to the external power supplies ALWAY...

Страница 4: ... clean cloth to clean the exterior of the device Keep the unit away from sources of heat such as heating appliances sunlight or central heating Switch off the unit and remove the battery during the extended periods of non operation Do not apply an excessive force or pressure to the lens assembly movable parts and thread connections Small dark and or light spots may be seen in the field of view due...

Страница 5: ...tic drawing 10 6 OPERATION INSTRUCTIONS 11 6 1 Installing battery 11 6 2 Switching the unit on 11 6 3 Switching the unit off 12 6 4 Adjusting to individual vision 12 6 5 Focusing 13 6 6 Auto shut OFF at bright light 13 6 7 Using the unit with headgear or helmet 14 6 8 Swinging head mounted unit for unobstructed view15 6 9 Using IR illuminator 15 6 10 Installation of add on lenses 16 6 11 Demist sh...

Страница 6: ...pe 20 6 16 Binocular configuration 21 7 TROUBLESHOOTING 22 7 1 No green light through eyepieces 22 7 2 Image is unclear 22 7 3 Image flashes 22 7 4 Condensation accumulates on the parts 22 7 5 Visibility decreased or disappeared 22 8 WARRANTY 23 9 CUSTOMER SUPPORT 24 10 ACCEPTANCE CERTIFICATE 25 ...

Страница 7: ...ion Two units can be combined to form a two eye optical system with the help of an optional bridge Unit can be mounted on a helmet headgear or used as a standalone monocular Some typical activities where NV207 G2 can be useful Law enforcement Wildlife observation Security Search and rescue Hunting Dark room photography connected to a camera Features Flip flop mechanism provides for unobstructed vi...

Страница 8: ...idge allows combining two monoculars into a binocular configuration Waterproof design 1 meter deep immersion for 30 minutes Soft rubber eyecup makes viewing comfortable Unit can be connected to photo or video camera Please read all the instructions carefully before using it Manufacturer reserves the right to introduce minor design changes without notice ...

Страница 9: ... cover 1 Manual 1 Lens cleaning kit 2 Carrying bag soft 1 AA Battery 1 Warranty card 1 2 1 Optional accessories US mount clip Bridge Demist shield Hard case Sacrificial window Lens brush 3x add on lens Camera video adapter 5x lens Helmet mount Weapon mount Exact Delivery Set is subject to the specific contract terms ...

Страница 10: ...5 2 Exit pupil diameter mm 21 Eye relief mm 25 Dioptric correction 5 6 Power supply 3V CR 123 Lithium battery 1 pc or 1 5 V AA Alkaline battery 1 pc Battery life hours Over 20 hours with I R Over 40 hours without I R Size mm 118x48x69 206x63x69 Weight monocular only g 300 540 NOTE Due to continuous design improvements parameters may vary from those given above ...

Страница 11: ...red illuminator and light sensor 3 Objective lens with lens cap 4 Eyepiece with eyecup 5 Headgear 6 Battery compartment cover with battery type adapter 7 Battery compartment 8 Tightening screw 9 Release button 10 Dovetail platform 1 8 5 6 7 10 9 3 4 2 FIGURE 1 ...

Страница 12: ...rter The input window is made of flat surface glass The output window is a concave fibre optics element with 180 image rotation 5 1 Main parameters IIT grade EPM 207G 2 11 22 IIT lp mm min 43 lp mm Photocathode operating diameter mm 17 5 Photocathode type S 25 Photocathode sensitivity min Integral A lm 450 500 Spectral at 850 nm mA W 26 30 Tube light amplification fl fc min 22 000 Image magnificat...

Страница 13: ... 15 Operating temperature range C 50 55 5 2 Spatial frequency contrast characteristics MTF Frequency lp mm 2 5 0 83 7 5 0 56 15 0 0 30 5 3 Field of view cleanness Allowed dot size mcm Zone Diameter mm 250 150 250 50 150 50 100 1 5 6 0 0 0 1 2 56 14 7 0 0 2 3 3 14 7 17 5 0 1 2 3 Dots with size 50 mcm are not accepted ...

Страница 14: ...10 5 4 Schematic drawing ...

Страница 15: ... 1 When using CR 123 Lithium type battery remove the battery type adapter Observe the polarity indicated on the housing Put the battery in and screw the battery cover back on 6 2 Switching the unit on In the daytime put on the lens cap with the daylight filter prior to switching the unit on To check if the unit is operational switch it ON rotate switch 1 Fig 1 clockwise and look through the eyepie...

Страница 16: ...our positions Off Auto On IR In Auto mode the monocular will switch off automatically when turned upright This mode saves battery life and allows avoiding greenish shadow on the face which may disclose the user Note The Auto switch position is optional 6 3 Switching the unit off After you have finished using the device turn it off by rotating switch 1 Fig 1 to OFF position Put a protective lens ca...

Страница 17: ... NBC protective mask you may like to fold the rubber eyecup 6 6 Auto shut OFF at bright light The NV207 G2 monocular has a built in high light sensor located near the IR illuminator 2 Fig 1 This sensor shuts the monocular off after about 45 second exposure to light exceeding 10 1 lux To reset the monocular switch it off and then back on as described in 6 3 and 6 2 High light shut off feature does ...

Страница 18: ...t firmly and does not slide off when you are moving The unit is attached to the headgear with a swing arm mount 1 Fig 3 To attach the arm mount to the headgear loosen the tightening screw 8 Fig 1 on headgear slide helmet groove 2 Fig 3 onto the rail and then tighten the screw To attach monocular to the arm turn the knob 3 Fig 3 slide the arm groove 4 Fig 3 along the dovetail platform of the monocu...

Страница 19: ...ounted unit for unobstructed view When the head mounted unit is not in use you can raise it to clear the view without taking the headgear off by using the flip flop feature To swing the unit from the view press the button 5 Fig 3 and raise the device until you hear a click In Auto position of the switch the monocular will turn off automatically Reverse the operation to return the unit to working p...

Страница 20: ...llowing procedure is identical for 3x lenses or any other add on lenses Turn off the monocular Remove the lens cap Press the lens firmly towards the eyepiece Do not apply excessive pressure Make sure that the lens is fixed well on the monocular To return the monocular back to 1x magnification pull off the lens FIGURE 4 NV207 G2 with attached 3x ...

Страница 21: ... the filter gently onto the eyepiece 6 12 Using the camera video adapter Before using the optional adapters remove the rubber eyepiece carefully The adapter Fig 5 consists of 2 rings a Camera adapter is 52x0 75mm It fits the filter lens thread of various cameras e g Nikon b Video adapter is 37x0 75mm It fits Sony cameras and some others If our adapter does not fit your camera obtain a proper step ...

Страница 22: ...ocking screw 1 Fig 6 and set a comfortable distance between the eyes and the eyepiece then tighten the locking screw back You can fixate the unit in three predetermined positions vertical horizontal and 15 20 degrees above horizontal Although the relative angles between these positions cannot be changed the starting point can be adjusted by screws 3 Fig 6 If you loosen them you can rotate the flip...

Страница 23: ... s Picatinny rail Two types of weapon mount adapters are available Fig 7 and Fig 8 Either adapter enables mounting the unit to the Picatinny rail The type shown on Fig 7 has two screws with large grooved heads for convenient tightening Note Over tightening the screws may damage the thread The Quick Release model Fig 8 utilizes a latch with a spring and patented accu torque screw You can attach and...

Страница 24: ... unit does not contain a reticle and thus cannot be used as a riflescope being mounted on a daytime riflescope or red dot sight it enables aiming at night In this configuration the objective lens of the unit is mounted on an eyepiece of the daytime scope with the help of an optional NVS Coupler Accu torque screw Latch with spring FIGURE 8 Quick Release adapter FIGURE 9 NVS Coupler ...

Страница 25: ...ovetail platform 10 Fig 1 located on both sides of the unit These platforms are identical The tightening screw 8 Fig 1 locks monocular to the bridge In this configuration the unit can be used in a goggle mounted on a headgear or handheld FIGURE 11 Goggles configuration FIGURE 12 Binoculars configuration In the dual configuration the interpupillary distance can be adjusted between 58 and 72 mm righ...

Страница 26: ... two minutes after activation It may continue flashing if exposed to bright light even with the lens cap on 7 4 Condensation accumulates on the parts When the unit is brought from the cold into a warm environment internal condensation may appear The unit has to be warmed up for up to two hours to regain full operational capacity 7 5 Visibility decreased or disappeared Bright light sources the Moon...

Страница 27: ...an equivalent along with the proof of the original purchase date to your Newcon Dealer Newcon will repair or at its option replace with the same or comparable model the product or part thereof which on inspection by Newcon is found to be defective in materials or workmanship What This Warranty Does Not Cover NEWCON is not responsible for warranty service should the product fail as a result of impr...

Страница 28: ...tern Standard Time Under no circumstances should the equipment be sent to Newcon without authorisation from our technical support department Newcon accepts no responsibility for unauthorized returns To locate NEWCON Authorized Dealer call 1 416 663 6963 or fax 1 416 663 9065 Email newconsales newcon optik com Web www newcon optik com The defective products should be shipped to From USA only 2331 S...

Страница 29: ...25 10 ACCEPTANCE CERTIFICATE Image Intensifier Tube serial number _____________________ Minimum Measured Resolution lp mm min 43 Photocathode sensitivity integral A lm 450 Light amplification 22 000 ...

Страница 30: ...ber _________________________________ The unit complies with all technical specifications and has passed the inspection Date of production _________________________________ Quality Inspector __________________________________ Quality Assurance Seal ...

Страница 31: ......

Страница 32: ...NEWCON OPTIK Printed in Canada ...

Отзывы: