![Newall DP900 Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/newall/dp900/dp900_manual_1678727032.webp)
29
Mill functions
Linear measurement mode
This can be used for height and length both inside and outside
measurements. Under this mode, there are different options:
1.
Press .
The message window shows ‘Probe - measure’.
2.
Select the measure mode by pressing the relevant soft key.
3.
Select the required axis by pressing the slider bar near the required
axis.
All axes revert to the showing position.
The probe message window shows ‘Move to Start Posn.’.
4.
Move to the start (0) position and touch.
The probe message window shows ‘Move to End Posn.’
5.
Move to end position and touch.
The results are shown, as per the measurement option.
6.
Press
to go the basic probe window.
This operation functions in both Incremental and Absolute modes
depending on the DRO operating status.
Angle measurement mode
This function can be used to measure angles on the work-piece. It can
also be used to calculate work-piece skew angles. The Angle
Measurement mode has different options.
Skew operation
1.
Press .
The message window shows ‘Probe - angle’.
2.
Press
.
The probe message window shows ‘Move to Position 1’.
3.
Move to the starting position and press [
enter
].
The probe message window shows ‘Move to Position 2’.
4.
Move to the next position and press [
enter
].
The probe message window shows ‘Move to Position 3’.
)
(1) Height and depth
(2) Stepped length (same)
(3) External feature
(4) Internal feature
X
Y
Angle
α
Angle
α
CW
Содержание DP900