1 Menu tree
1.5 MAIN MENU – Positioning
134
FST_HB.EN04/03
Relevel. Limits –
Limit DN OFF
The relevelling when moving down stops at the set distance
between car and levelling position (see “Relevel. Limits” on
page 138).
0 ... 2500 mm
Cal-Results –
UP–Speed
Speeds measured during the calibration drive for all drive
speeds V1 … VI for upward travel.
-10000...10000 mm/s
Cal-Results –
UP–Accel.
Acceleration distances measured during the calibration drive
for all drive speeds V1 … VI for upward travel.
0 ... 50000 mm
Cal-Results –
UP–Decel.
Deceleration distances measured during the calibration drive
for all drive speeds V1 … VI for upward travel.
0 ... 50000 mm
Cal-Results –
UP–t_Accel.
Acceleration times measured during the calibration drive for
all drive speeds V1 … VI for upward travel.
0 ... 32767 msec
Cal-Results –
UP–t_Decel.
Deceleration times measured during the calibration drive for
all drive speeds V1 … VI for upward travel.
0 ... 32767 msec
Cal-Results –
DOWN–Speed
Speeds measured during the calibration drive for all drive
speeds V1 … VI for downward travel.
-1000 ... 10000 mm/s
Cal-Results –
DOWN–Accel.
Acceleration distances measured during the calibration drive
for all drive speeds V1 … VI for downward travel.
0 ... 50000 mm
Cal-Results –
DOWN–Decel.
Deceleration distances measured during the calibration drive
for all drive speeds V1 … VI for downward travel.
0 ... 50000 mm
Cal-Results –
DOWN–t_Accel.
Acceleration times measured during the calibration drive for
all drive speeds V1 … VI for downward travel.
0 ... 32767 msec
Cal-Results –
DOWN–t_Decel.
Deceleration times measured during the calibration drive for
all drive speeds V1 … VI for downward travel.
0 ... 32767 msec
Cal-Results –
V80%–SpeedMon
Speed monitoring point for deceleration monitoring when
approaching the levelling position of the top or bottom landing
(see “End-Sw.Speed Mon.” on page 114).
0 ... 10000 mm
Cal-Results –
V80%–Distance
Speed monitoring point for deceleration monitoring when
approaching the levelling position of the top or bottom landing
(see “End-Sw.Speed Mon.” on page 114).
0 ... 49999 mm
Pseudo Floors –
Pos. (Rel.)
Additional stops without shaft doors. “Pseudo Floors” are
additional floors without call signals or doors. They can only be
approached using the programmable inputs/outputs and are
used as locking positions for cable lifts without machine
compartment or as parking floors between regular floors.
0 ... 49999 mm
Increm. Positng. –
Control
Control register for incremental positioning:
Default setting for this parameter:
00001000
Only change this setting after consulting NEW LIFT!
00000000 ...
11111111
Menu item
Description
Setting range
Содержание FST
Страница 1: ...Manual Field Bus Controller ...
Страница 6: ...Table of Contents 4 FST_HB EN04 03 ...
Страница 43: ...4 Technical Data 4 2 FST Controller FST_HB EN04 03 41 Fig 4 2 FST Controller ...
Страница 98: ...4 Technical Data 4 13 Trailing cable 96 FST_HB EN04 03 Fig 4 14 Trailing cable version 1 ...
Страница 102: ...4 Technical Data 4 13 Trailing cable 100 FST_HB EN04 03 ...
Страница 104: ...1 Menu tree 1 1 General 102 FST_HB EN04 03 Fig 1 1 FST Controller menu tree part 1 ...
Страница 105: ...1 Menu tree 1 1 General FST_HB EN04 03 103 Fig 1 2 FST Controller menu tree part 2 ...
Страница 106: ...1 Menu tree 1 1 General 104 FST_HB EN04 03 Fig 1 3 FST Controller menu tree part 3 ...
Страница 107: ...1 Menu tree 1 1 General FST_HB EN04 03 105 Fig 1 4 FST Controller menu tree part 4 ...
Страница 108: ...1 Menu tree 1 1 General 106 FST_HB EN04 03 Fig 1 5 FST Controller menu tree part 5 ...
Страница 109: ...1 Menu tree 1 1 General FST_HB EN04 03 107 Fig 1 6 FST Controller menu tree part 6 ...
Страница 110: ...1 Menu tree 1 1 General 108 FST_HB EN04 03 Fig 1 7 FST Controller menu tree part 7 ...
Страница 111: ...1 Menu tree 1 1 General FST_HB EN04 03 109 Fig 1 8 FST Controller menu tree part 8 ...
Страница 112: ...1 Menu tree 1 1 General 110 FST_HB EN04 03 Fig 1 9 FST Controller menu tree part 9 ...
Страница 138: ...1 Menu tree 1 5 MAIN MENU Positioning 136 FST_HB EN04 03 Fig 1 14 Parameters for linear positioning ...
Страница 139: ...1 Menu tree 1 5 MAIN MENU Positioning FST_HB EN04 03 137 Fig 1 15 Additional parameters for incremental positioning ...