7 Error List
7.4 Error messages
FST_HB.EN12/05
177
16
DRM-ENCODER FAILURE
Plausibility testing of car position
with the encoder is faulty.
Reset
TEST MENU - Fault
Reset
.
-
The encoder is faulty.
-
Check electric connection of
the encoder.
-
During commissioning: Check
direction of rotation of the
encoder and carry out “Set
Floor 0”.
17
DRM-CAR COMMS FAIL
Communication between the FST-
Controller and the FSM car control
module is faulty.
-
Plug-in connections of the
trailing ribbon cable are not
plugged or are loose.
-
Rupture in trailing ribbon cable.
-
FSM car control module faulty.
-
Check jumper position JK1,
JK2 and JK3 on the car control
module.
18
DRM-END FLOOR SPEED
Reset
TEST MENU - Fault
Reset
.
The delay control circuit at the
top and bottom limits has
triggered.
19
DRM-MISSING ZONE
No zone message available.
Reset
TEST MENU - Fault
Reset
.
The car has reached a levelling
position but does not receive a
zone message from the safety
circuit.
Check safety circuit and zone
solenoid switches.
20
DRM-BRAKE FAILURE
The brakes do not react or cannot be
released.
Reset
TEST MENU - Fault
Reset
.
-
The brake does not release
even with pre-selection active.
-
The brake does not close even
with the car stopped.
Monitoring via inputs FST X1.19
and X1.20 (see “Brake
monitoring” on page 106).
21
DRM-MOTOR FAILURE
Temperature monitoring of the drive
has triggered.
Motor overheated.
Monitoring via input FST X1.22
(see “Motor monitoring” on
page 106).
22
DRM-FORCED STOP
The input signal “Forced Stop” on a
programmable input was active. The
car is shut down on the floor with the
door open.
Please refer to the system
specific wiring diagrams for
information on which signal has
triggered the forced stop. Also
see “Programmable inputs and
outputs” on page 147.
23
DRM-EMERG.LIMIT SW
Exceeding the top floor according to
EN81 (for hydraulic lifts).
Reset
TEST MENU - Fault
Reset
.
The top emergency end switch
has triggered. The contact is
sampled by terminal FST X14.6
(“TC”).
24
DRM-DOOR FAILURE
The car door cannot be moved.
Reset
TEST MENU - Fault
Reset
.
Door control is active but the car
door does not move. The
controller shuts down the
system.
Code
Message
Description
Reason
Содержание FST-2
Страница 6: ...Table of contents 4 FST 2_HB EN12 05...
Страница 98: ...5 Menu tree 5 1 General 96 FST 2_HB EN12 05 Fig 5 1 FST 2 Controller menu tree part 1...
Страница 99: ...5 Menu tree 5 1 General FST 2_HB EN12 05 97 Fig 5 2 FST 2 Controller menu tree part 2...
Страница 100: ...5 Menu tree 5 1 General 98 FST 2_HB EN12 05 Fig 5 3 FST 2 Controller menu tree part 3...
Страница 101: ...5 Menu tree 5 1 General FST 2_HB EN12 05 99 Fig 5 4 FST 2 Controller menu tree part 4...
Страница 102: ...5 Menu tree 5 1 General 100 FST 2_HB EN12 05 Fig 5 5 FST 2 Controller menu tree part 5...
Страница 103: ...5 Menu tree 5 1 General FST 2_HB EN12 05 101 Fig 5 6 FST 2 Controller menu tree part 6...
Страница 104: ...5 Menu tree 5 1 General 102 FST 2_HB EN12 05 Fig 5 7 FST 2 Controller menu tree part 7...
Страница 105: ...5 Menu tree 5 1 General FST 2_HB EN12 05 103 Fig 5 8 FST 2 Controller menu tree part 8...
Страница 112: ...5 Menu tree 5 3 MAIN MENU Drive 110 FST 2_HB EN12 05 Fig 5 10 Drive with speed correction function...
Страница 133: ...5 Menu tree 5 5 MAIN MENU Positioning FST 2_HB EN12 05 131 Fig 5 13 Parameters for linear positioning...
Страница 134: ...5 Menu tree 5 5 MAIN MENU Positioning 132 FST 2_HB EN12 05 Fig 5 14 Additional parameters for incremental positioning...
Страница 140: ...5 Menu tree 5 7 MAIN MENUE System 138 FST 2_HB EN12 05 Event channels Fig 5 16 Event channels of the FST 2 Controller...
Страница 174: ...6 Programmable inputs and outputs 172 FST 2_HB EN12 05...