General Alarms
Alarm
Title
Description
WSM Spreader
Module
Local CAN Bus Error
Check the local CAN bus connection�
WSM Spreader
Module
Module Software Reset
The module software reset due to an
unhandled error�
WSM Spreader
Module
Local CAN Bus Warning
Check the local CAN bus connection�
WSM Spreader
Module
Local ISOBUS Error
Check the ISOBUS connections�
WSM Spreader
Module
Local ISOBUS Warning
Check the ISOBUS connections�
WSM Spreader
Module
CAN Power Voltage Low
The CAN power voltage is below 8�0
volts� Check CAN bus power supply�
WSM Spreader
Module
High Power Voltage Low
The high power voltage is below
10�0 volts� Check high power supply
connections�
WSM Spreader
Module
Bin Not on Bus
Bin set as installed is not on bus� Check
wiring or edit the profile.
WSM Spreader
Module
Body Module Offline
The body module is no longer
available� Check power supply and
communication wiring�
WSM Spreader
Module
Module Indexing Failure
System has not indexed itself properly�
This can be caused by a missing index
pin in the cabling�
Controller Operations
Содержание AGCO NL4258
Страница 6: ...Insert Current New Leader Warranty Warranty...
Страница 41: ...41 NL4258 4330G4 EDGE www NewLeader com 800 363 1771 312521 AA C Insert Installation Single Bin...
Страница 42: ...42 www NewLeader com 800 363 1771 312521 AA C NL4258 4330G4 EDGE Insert Installation MultApplier...
Страница 44: ...44 This page is intentionally left blank www NewLeader com 800 363 1771 312521 AA C NL4258 4330G4 EDGE Notes...
Страница 54: ...54 This page is intentionally left blank www NewLeader com 800 363 1771 312521 AA C NL4258 4330G4 EDGE Notes...
Страница 78: ...78 This page is intentionally left blank www NewLeader com 800 363 1771 312521 AA C NL4258 4330G4 EDGE Notes...
Страница 106: ...106 www NewLeader com 800 363 1771 312521 AA C NL4258 4330G4 EDGE Notes This Page Intentionally Left Blank...