New Age Hi-Laser Beta LASER Скачать руководство пользователя страница 1

ß

 LASER

 

 

 

 

 

 

 

MANUAL 

 

Instructions for use 

 

 

New Age Italia

 

srl

 

Via De Brozzi, 3 -  48022 Lugo (RA) 

Tel.:+39-0545.32019  -  Telefax: +39-0545.369028 

Web

www.newageitalia.it

  -  E-mail: 

[email protected]

  

 

 
 

This  document  is  property  of  New  Age  Italia  srl.  All  rights  are  reserved.  Any  copy  or 
reproduction of it through any means, including total or partial photocopy of the contents, is 
prohibited without the written consent of New Age Italia srl. 

Содержание Hi-Laser Beta LASER

Страница 1: ...ax 39 0545 369028 Web www newageitalia it E mail info newageitalia it This document is property of New Age Italia srl All rights are reserved Any copy or reproduction of it through any means including...

Страница 2: ...Rev 00 of 14 01 10 2 24...

Страница 3: ...mulation 10 2 4 Setting time and intensity of emission 10 2 5 Interrupt end therapy 10 2 6 Turning device off 10 2 7 Configuration 10 Cap 3 PRE SET PROGRAMS 11 Cap 4 FREE PROGRAMS 12 4 1 Setting a new...

Страница 4: ...7 9 4 Other features 17 Cap 10 BASIC SUPPLY AND ACCESSORIES 18 10 1 Basic supply 18 10 2 Accessories and consumption material 18 ATTENTION READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE USE IT IS RECOM...

Страница 5: ...lable its experience in the physiotherapy field through the various programs that each appliance owns this enables the operator to be operational and efficient right from the first applications obtain...

Страница 6: ...rocirculation One of the effects deriving from using the high power LASER is the distinct vasoactive effect on the microcirculation The activation of the microcirculation entails greater oxygenation a...

Страница 7: ...rthritis arthritis arthrosis sciatica lumbago General traumatology articular sprains tendonitis tenosynovitis muscle strains bruises bursitis enthesitis torn muscles pathologies of overload muscular i...

Страница 8: ...Cap 2 OPERATION NOTE check the contraindications and follow indications carefully before applying LASER therapy 2 Knob push button 6 Stop button 1 Touch screen display 3 safety key 4 Optical fibre ou...

Страница 9: ...erned parameters are type of emitted wave supplied power therapy duration duty cycle of the generated wave 2 2 2 Reset program mode Press START on the initial screen touch screen to access the work ar...

Страница 10: ...PRESS THE KNOB repeatedly to pass from the intensity parameter to the time parameter and vice versa The minimum density increase is of 1 and the maximum settable intensity is 100 the minimum time incr...

Страница 11: ...ogies which can benefit from the effects of electromagnetic fields chronic pathologies articular problems oedemas etc This chapter lists the programs pre set inside the device LASER has 30 different p...

Страница 12: ...phase Press PARAMETERS on touch screen to move the cursor in the work phase setting section In this zone ROTATE THE KNOB to set the parameter value and PRESS THE KNOB to pass from one parameter to an...

Страница 13: ...changed during the program to increase its affects It can also be decreased in case of overheating or if pain is felt The device is endowed with a special function that allows to have safer treatment...

Страница 14: ...k or facedown depending on the zone of application This position must be maintained during the entire session to facilitate the effects produced by the laser beam especially the increased the blood fl...

Страница 15: ...r or other parts are damaged broken or missing it appears that the features of the device have been changed for safety purposes do not operate with accessories e g knobs and power supply other than th...

Страница 16: ...rature between 5 and 40 C and less than 80 humidity The same conditions must be maintained during transportation and storage In case of malfunctioning and failures do not use the device but send it to...

Страница 17: ...standards EN 60601 1 1 2003 Collateral safety standard EN 60601 1 2 2003 Collateral standard Electromagnetic compatibility Provisions and tests EN 60601 1 4 1997 Collateral standard Programmable elect...

Страница 18: ...e goggles for the patient N 1 knob 1 power cable 1 User manual N 1 Trolley 1 0 2 A c c e s s o r i e s a n d c o n s u m p t i o n m a t e r i a l The following is the list of accessories which can be...