During inspection procedure, make sure that
each ferrule is completely free of dust.
As a reference the ferrule has to look as
illustrated on Picture B.
BDA 520
Dry Cleaner 1.25 mm (FOCD-DC125)
opticalCON
E
Insert the video probe tool into our NEUTRIK FOCD-
STD service tool (D).
To inspect the LC ferrule surface focus the video
probe by rotating the focus wheel (E).
Clean the LC surface with the Dry Cleaner 1.25 mm
over the NEUTRIK DUO service tool.
Push back and forth the dry cleaner to start the
cleaning procedure (F). An endless lint free tape
removes dust particle on the ferrule surface of the LC
connector.
Check the condition of the LC ferrule surface again
and if necessary repeat step 7.