8 Faults
Translation of the original Operating / Installation Instructions 2016/09 Rev.1 51/63
8.2
Faults and Remedial Action
Fault
Cause
Remedy
Effectiveness of the
cleaning process is
inadequate
Pressure for the cleaning fluid
is insufficient or no cleaning
fluid pressure.
Check the pressure of the cleaning
agent
Check the filter and clean it if necessary
Check the outlet opening on the device
and clean it if necessary
Pressure of the cleaning agent
too high, cleaning agent turns
into mist
Check the pressure of the cleaning
agent and reduce pressure if necessary
Spray head does
not rotate
Holes blocked
Clean holes
Holes deformed
Replace the device
Sliding surfaces soiled
Clean the device
Device is worn
Replace the device
Table 8.2-1: Operating Faults – Cause and Remedy
If the specified measures are NOT successful, please contact AWH.