NeuLog NUL-207 Скачать руководство пользователя страница 1

NEULOG RELATIVE HUMIDITY SENSOR GUIDE

 

 

 

NeuLog Relative Humidity logger sensor 
NUL-207 

 
The NeuLog relative humidity sensor can be used for any science experiment or 
activity which requires an accurate relative humidity reading such as in the fields of 
Biology, Physiology, Exercise Science, Chemistry, Environmental Science, Earth 
Science, Weather Science, Botany, Entomology, etc.   
 
The sensor comes pre-calibrated so you can start experimentation right out of the box 
using any of the following guides.   
 
Just a few of the thousands of possible experiments that can be done with the NUL-
207 sensors are: perspiration, photosynthesis rates, insect behavior, water vapor 
emitting chemical reactions, ecological studies, animal behavior, weather patterns, 
and many more. 
 
Relative humidity is a measurement which examines the ratio of water vapor present 
in the air compared with the maximum amount of water vapor that the air can hold for 
a specific temperature. 

 

Data is presented as a percentage which is a ratio of the amount of water 
vapor in the air versus the maximum amount that could be allowed at a 
given temperature.  

 

Quick start procedure: 

 

PC or Mac Computer 

 

Materials needed: 
 

 

NUL-207 Relative Humidity Sensor 

 

USB-200 USB Module 

 

A USB to mini USB cable (which comes with the USB-200) 

 
Your  relative  humidity  sensor  needs  to  be  connected  to  a  USB-200  module.    The 
USB-200 module then connects to a computer via a USB to mini-USB cable.  Please 
note that you cannot plug the relative humidity sensor directly into the computer. 
 

Resident  PC  software  and  browser  based  software  can  be  downloaded  for  free  at 

www.NeuLog.com/dowload

 as well as a full software user guide.

  Note:

 Make sure not 

to download and install both types of software they will conflict on the computer. 
 

Procedure: 

 

1. 

Install the NeuLog software 

2. 

Connect the USB-200 module to the PC or Mac 

3. 

Connect the relative humidity sensor to the USB-200 module (they directly 
plug together).  Please note there is no calibration required for this sensor. 

4. 

Open the NeuLog software. 

5. 

Once a relative humidity sensor logo appears on the left side of the screen 
the probe has been automatically identified and you can begin 
experimentation. 

6. 

If the relative humidity sensor is not automatically identified then click the 
“Search for sensors” icon to find the sensor. 

7. 

Select the “On-line experiment” button; this will open a graph below. 

8. 

Click on the “Module setup” button located on the relative humidity sensor 
icon in the module window to change the sensor settings if need be. 

9. 

Click on the experiment set up button to change the experiment settings if 
need be (experiment duration for example). 

10.  The relative humidity sensor will give a live reading in the box to the left of 

the screen while plugged in. 

11. 

To run an experiment and collect data click “Run experiment”. 

12. 

To end data collection early, click “Stop experiment”. 

 

Tablet, smart phone device 

 

Materials needed: 
 

 

NUL-207 Relative Humidity Sensor 

 

WIFI-201 WIFI module 

 

BAT-200 Battery 

 
Your relative humidity sensor needs to be connected to a WIFI-201 module. The WIFI-
201  module  will  create  a  closed  NeuLog  wifi  network  which  will  stream  the  NeuLog 
data  to  a  device  of  your  choosing.  Once  your  device  is  wirelessly  connected  to  the 
NeuLog network you can run experiments and collect data through a browser of your 
choosing. 

Отзывы: